• Title/Summary/Keyword: Power Detection System

Search Result 1,402, Processing Time 0.033 seconds

Fault Section Detection Scheme in Ungrounded Distribution System (비접지 배전계통에서 고장구간 검출 및 복구 알고리즘)

  • Yu, Fei;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.487-488
    • /
    • 2007
  • Fault section detection and service restoration is very important in ungrounded distribution system. Techniques currently used to track down faults are time consuming and cumbersome. A new scheme is developed based on communication technology, and the simulation result shows that the method can satisfy the requirement proposed.

  • PDF

A Study on the Collision Detection for Smart Door by Disturbance Observer (외란관측기를 이용한 스마트도어의 충돌감지에 관한 연구)

  • Park, Min-Kyu;Sung, Kum-Gil;Lee, Byungsoo
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.31-36
    • /
    • 2011
  • Smart Door(SD) is a human friendly power-assisted door system for passenger car doors. It offers comfort and safety to passengers and drivers by supplying additional power. In this study, dynamic system model and the equation of motion derivation are derived. And we propose the disturbance observer based collision detection algorithm for safety when opening the door. A disturbance caused by collision has a fast response compared to a friction, uncertainties and so on. The main idea this study is to estimate a variation of disturbance for stably and effectively detecting a collision. In order to evaluate a performance of collision detection, an experiment set up is constructed. The experimental results validate the usefulness of the proposed collision detection algorithm.

Implementation of Coupler for Live Wire Fault Detection System using Time-Frequnecy Domain Reflectometry (커플러를 이용한 활선 상태 배선 진단 시간-주파수 영역 반사파 계측 시스템 구현)

  • Doo, Seung-Ho;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1541-1542
    • /
    • 2008
  • In this paper, we introduce a live wire power transmission line fault detection system using time-frequency domain reflectometry(TFDR). The TFDR is known that is more precise method than the other conventional ones. However, the TFDR is generally adopted only in fault detection for communication cable, and dead line power transmission line. Therefore, this paper suggests a TFDR system with coupler which separates 220V, 60Hz signal and TFDR reference signal for implementation the live wire fault detection system. This approach is verified by circuit simulation.

  • PDF

Fault Detection and Isolation of Parallel Operation of Two Converters Using Zero Current Transformer Method (영상변류기 동작 방식을 이용한 2개의 컨버터 병렬 운전시 고장 탐지 및 분리)

  • 손승찬;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.409-416
    • /
    • 2000
  • In case of operating two converters in parallel with ZCT operation method using one current sensor for fault tolerance by system characteristics, identifying fault detection and isolation is difficult of which converter is fault since the ZCT output is a difference of two converters' supply current when a converter has fault. This thesis suggest a fault detection and isolation method of converter in case of operating two converters in parallel for fault tolerant system and verified this suggested method through an experiment.

  • PDF

Fault Detection and Classification with Optimization Techniques for a Three-Phase Single-Inverter Circuit

  • Gomathy, V.;Selvaperumal, S.
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1097-1109
    • /
    • 2016
  • Fault detection and isolation are related to system monitoring, identifying when a fault has occurred, and determining the type of fault and its location. Fault detection is utilized to determine whether a problem has occurred within a certain channel or area of operation. Fault detection and diagnosis have become increasingly important for many technical processes in the development of safe and efficient advanced systems for supervision. This paper presents an integrated technique for fault diagnosis and classification for open- and short-circuit faults in three-phase inverter circuits. Discrete wavelet transform and principal component analysis are utilized to detect the discontinuity in currents caused by a fault. The features of fault diagnosis are then extracted. A fault dictionary is used to acquire details about transistor faults and the corresponding fault identification. Fault classification is performed with a fuzzy logic system and relevance vector machine (RVM). The proposed model is incorporated with a set of optimization techniques, namely, evolutionary particle swarm optimization (EPSO) and cuckoo search optimization (CSO), to improve fault detection. The combination of optimization techniques with classification techniques is analyzed. Experimental results confirm that the combination of CSO with RVM yields better results than the combinations of CSO with fuzzy logic system, EPSO with RVM, and EPSO with fuzzy logic system.

Development of Algorithm and Program for the Ground Fault Detection in Ungrounded Distribution Power System (비접지 배전계통 지락고장 검출 알고리즘 및 프로그램 개발)

  • Park, So-Young;Shin, Chang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2619-2627
    • /
    • 2009
  • The ground fault is occupying 70% among the total number of faults in ungrounded distribution power system. When the ground fault occurs in ungrounded system, the fault current is so small that it is hard to detect. But fault handling is very important because to continue power supply during fault conditions may cause the fault spreading and the distribution device in trouble. This paper presents the fault line detection method by using GPT signal detecting zero sequence voltage, and the fault section detection method by detecting whether GPT signal is disappeared or not during shifting normally open switch, which is connecting switch between distribution lines with open state in order to restore the outage area under emergency situation, and during isolating each section one by one which belongs to the fault line. This method is efficient because there is no whole power interruption during the fault section detection, and it is possible to perform both the fault section detection and the service restoration for the outage area at the same time, and it can apply to various distribution system configuration. Program for the fault restoration was developed applying proposed method, and it has been validated by applying to the pilot project of distribution automation system in Vietnam which has the ungrounded distribution system.

Development of Arc Detection Algorithm for 50 kW Photovoltaic System (50kW 태양광 설비의 아크 검출 알고리즘 개발)

  • Kim, Sang-Kyu;Lee, Chang-Sung;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.27-32
    • /
    • 2018
  • In this paper, we developed an algorithm to detect arc of PV power plant through frequency analysis. For arc detection based on frequency analysis, the filter should be designed to emphasize the difference between the arc state and the normal state. Therefore, in this paper, we analyzed the arc detection performance according to various filter structures. The arc detection algorithm developed in this paper extracts the filtering signal on current by using various filters and then calculates the frequency components and total energy using the FFT. In the final step, the arc is detected using the calculated energy magnitude. In order to verify the performance of the proposed arc detection algorithm, experiments were conducted on 51 kW solar inverters connected to power line. Through various experiments, it was confirmed that the proposed method effectively detects the arc.

A Conflict Detection Method Based on Constraint Satisfaction in Collaborative Design

  • Yang, Kangkang;Wu, Shijing;Zhao, Wenqiang;Zhou, Lu
    • Journal of Computing Science and Engineering
    • /
    • v.9 no.2
    • /
    • pp.98-107
    • /
    • 2015
  • Hierarchical constraints and constraint satisfaction were analyzed in order to solve the problem of conflict detection in collaborative design. The constraints were divided into two sets: one set consisted of known constraints and the other of unknown constraints. The constraints of the two sets were detected with corresponding methods. The set of the known constraints was detected using an interval propagation algorithm, a back propagation (BP) neural network was proposed to detect the set with the unknown constraints. An immune algorithm (IA) was utilized to optimize the weights and the thresholds of the BP neural network, and the steps were designed for the optimization process. The results of the simulation indicated that the BP neural network that was optimized by IA has a better performance in terms of convergent speed and global searching ability than a genetic algorithm. The constraints were described using the eXtensible Markup Language (XML) for computers to be able to automatically recognize and establish the constraint network. The implementation of the conflict detection system was designed based on constraint satisfaction. A wind planetary gear train is taken as an example of collaborative design with a conflict detection system.

A Novel Fault Detection Scheme for Voltage Fed PWM Inverter (전압형 PWM 인버터의 새로운 고장 검출 기법)

  • Yu, Ok-Sun;Park, Nam-Ju;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • This paper presents a new fault detection scheme for voltage fed inverter to improve the reliability of power electronic system, which is of paramount importance in the wide industrial applications. The proposed method is achieved by using voltage across lower switches in each phase under the switch fault condition. The reconfiguration method is achieved by the four-switch topology connecting a faulty leg to the middle point of DC-link using bidirectional switches. The proposed method has a simple algorithm and fast fault detection time. Therefore, normal operation of the system after faults is continuously achieved by reconfiguration of system topology. The superior performance of the proposed fault detection and tolerance method are proved by simulation.

Detection Performance and THD Analysis of Active Frequency Drift for Anti-Islanding (단독운전 방지를 위한 능동적 주파수 변환 기법의 검출 성능 및 THD 분석)

  • Jo, Yeong-Min;Choi, Ju-Yeop;Song, Seung-Ho;Choy, Ick;Lee, Young-Kwoun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.11-19
    • /
    • 2015
  • Islanding is a phenomenon that EPS(Electric Power System) is continuously energized by PV PCS(Photovoltaic Power Conditioning System) even when EPS is isolated from the grid. Unintentional islanding will result in safety hazard, power quality degradation and many other issues. So, islanding protection of grid-connected PV PCS is a key function for standards compliance. Nowadays, many anti-islanding schemes are researched. But existing anti-islanding schemes used in PV PCS have power quality degradation and non-detection zone issues. This paper analyses not only detection performance of existed anti-islanding schemes using active frequency drift but also THD of PCS output current according to each value disturbance for anti-islanding. In addition, the lowest value of disturbance in each scheme was tabulated under guarantee of anti-islanding condition.