• Title/Summary/Keyword: Power Control Error

Search Result 1,077, Processing Time 0.032 seconds

A Novel Rotor Position Error Calculation Method using a Rotation Matrix for a Switching Frequency Signal Injected Sensorless Control in IPMSM (스위칭 주파수 신호 주입 IPMSM 센서리스 제어를 위한 회전 행렬 기반의 새로운 위치 오차 추정 기법)

  • Kim, Sang-Il;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.402-409
    • /
    • 2015
  • This paper proposes a novel rotor position error calculation method for high-frequency signal-injected sensorless control. The rotor position error using the conventional modulation method can be only measured up to ${\pm}45^{\circ}$. In addition, when the rotor position estimation error is not sufficiently small, the small angle approximation in no longer valid. To overcome these problems, this study introduces a new rotor position error calculation method using the rotating matrix. In this study, the position error measurement range of the proposed method is extended from ${\pm}45^{\circ}$ to ${\pm}90^{\circ}$. The linearity between the real rotor position error and the estimated error is maintained by nearly $90^{\circ}$. These features of the proposed method improve the performance of the sensorless control. The validity of the proposed method is verified by simulations and experiments.

Optimal Current Detect MPPT Control of PV System for Robust with Environment Changing (환경변화에 강인한 태양광 발전의 최적전류 MPPT 제어)

  • Choi, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.47-58
    • /
    • 2011
  • This paper proposes the optimal current detect(OCD) maximum power point tracking(MPPT) control of photovoltaic(PV) system for robust with environment changing. The output characteristics of the solar cell is a nonlinear and affected by a temperature, the solar radiation and temperature. Conventional MPPT control methods are tracked the maximum power point by constant incremental value. So these methods are slow the response speed and generated the vibration in steady state and cannot track the MPP in environment condition changing. And power loss is generated because of the self-excitation vibration in MPP region. To solve this problem, this paper proposes the novel control algorithm. Proposed algorithm is detected the optimal current in two control region using the output power and current curve. Detected current is used the converter switching for tracking the MPP. Proposed algorithm is compared output power error to conventional algorithm with radiation and temperature changing. In addition, the validity of the algorithm is proved through the output error response characteristics.

The Design of the Amplitude and Phase Control Circuit for the Error Sensor Loop in Feedforward Linearizer System (Feedforward 선형화기 시스템의 오차 추출 루프를 위한 크기와 위상 제어 회로의 설계)

  • Nam, Sang-Dae;Park, Ung-Hui;Jang, Ik-Su;Yun, Sang-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.2
    • /
    • pp.91-97
    • /
    • 2000
  • Tn this paper, a novel control circuit applicable to the error sensor loop block in the feedforward linearizer system is proposed. The proposed control circuit is applied to the error sensor loop block, where in the 11dB power range, it operates stably, and makes main carrier signals to be eliminated more than 40dB below 3$\^$rd/ order IM level. In the operating point, the amplitude control error is 0.05∼0.12dB, and the phase control error is smaller than 0.02。. It is verified theoretically as well as experimentally that the control circuit can precisely compensate the variation of nonlinear characteristics in a high power amplifier, due to the variations of input power, operating temperature, humidity and the other system environments.

  • PDF

Design of the Modified PID Speed Controller to Reduce the Speed Ripple (속도 리플 억제를 위한 수정된 PID 속도 제어기의 설계)

  • Kim, Hong-Min;Choo, Young-Bae;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.135-141
    • /
    • 2012
  • PMSM(Permanent Magnet Synchronous Motor) has periodic torque ripple from the cogging torque and load conditions. This paper proposes the modified PID speed controller to reduce the speed ripple of the PMSM. The proposed modified PID controller uses a selective D(Differential) control term according to the speed error and the differential of the speed error. The proposed speed controller produces an additional torque reference such as torque compensator based on PI controller according to the speed error and the differential of the speed error, and it can reduce the vibration of the conventional D-control term with reduced speed ripple. Since the additional torque reference of the proposed speed controller is changed by the sign of the speed error and the differential of the speed error, a simple function to determine the sign of the error is used to produce the compensated torque. The proposed control scheme is verified by the computer simulation and the experiments.

Performance Analysis of D2D Power Control To Compensate Channel Estimation Error

  • Oh, Changyoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.5
    • /
    • pp.65-72
    • /
    • 2020
  • To improve the performance of D2D power control algorithm proposed in the previous work, three modified D2D power control algorithms are proposed to compensate the channel estimation error. Then, we evaluate the performance of three modified D2D power control algorithms in the channel estimation error environment. In real channel environment, the channel estimation is not perfect. To that end, the impact of imperfect channel estimation on the D2D power control algorithm, which was developed with the assumption of perfect channel estimation, has been analyzed in the previous work. Three modified D2D power control algorithms are based on 1) Retransmission, 2) SIR Margin, and 3) Retransmission and SIR Margin. Simulation results show that the Retransmission and SIR Margin approach shows best performance in the sense of the transmit power consumption and the latency.

A method and analysis of human-error management of a semiconductor industry (반도체산업에서의 인적오류제어방법 및 연구)

  • Yoon Yong-Gu;Park Peom
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.1
    • /
    • pp.17-26
    • /
    • 2006
  • Basis frame-work's base in a semiconductor industry have gas, chemical, electricity and various facilities in bring to it. That it is a foundation by fire, power failure, blast, spill of toxicant huge by large size accident human and physical loss and damage because it can bring this efficient, connect with each kind mechanical, physical thing to prevent usefully need that control finding achievement factor of human factor of human action. Large size accident in a semiconductor industry to machine and human and it is involved that present, in system by safety interlock defect of machine is conclusion for error of behaviour. What is not construing in this study, do safety in a semiconductor industry to do improvement. Control human error analyzes in human control with and considers mechanical element and several elements. Also, apply achievement factor using O'conner Model by control method of human error. In analyze by failure mode effect using actuality example.

Effects of Elastic Taping on the Power and Velocity Error of Rectus Femoris after Muscle Fatigue Occurred (탄력성 테이핑이 근 피로를 적용한 넙다리곧은근의 파워오차와 속도오차에 미치는 영향)

  • Yoon, Junggyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • Purpose : The purpose of this study was to examine the effects of elastic taping on the power and velocity error of rectus femoris after muscle fatigue occurred. Method : The subjects of this study were 15 healthy students. The Primus RS was used to measure the power and velocity error of rectus femoris after muscle fatigue occurred. The power and velocity error were measured 3 times which are consist of pre-fatigue, after-fatigue and after 24 hours applied elastic tape on rectus femoris. A elastic tape was attached to rectus femoris between the antero inferior iliac spine (AIIS) and the tibia tuberosity. The collected data was analyzed using one-way repeated-measures ANOVA for comparison of the power and velocity error according to the measured time and Pearson test for correlation between the power and velocity error according to the measured time. Level of significance was set at 0.05. Result : No significant differences of the power and velocity error were found between $1^{st}$ and 2nd, 3rd measurements (p>.05). The power and velocity error, after 24 hours, of the applied elastic tape with muscle fatigue was significantly lower than muscle fatigue with no taping(p<.05). No significant correlations were found between the power and velocity error according to the measured time(p>.05). Conclusion : After applying the elastic tape on the rectus femoris, muscle fatigue occurred, which improved proprioception by decreasing movement error. It will be an important intervention to prevent musculoskeletal injuries and to enhance the motor control in exercise.

Average Current Control of Active Power Filters Using Predictive Current Controller (예측전류제어기를 이용한 능동전력필터 시스템의 평균치 전류제어)

  • Kim, Min-Keuk;Woo, Myung-Ho;Jeong, Seung-Gi;Park, Ki-Won;Choi, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.295-299
    • /
    • 1996
  • When the current of a power converter is controlled with a digital controller, it generally shows the error due to execution time delay. The error may be considerable in such systems as active power filters wherein the current varies steeply even in steady state, as well as in transients. Therefore, it is of particular importance to compensate the time delay effect in a digitally-controlled active power filter. This paper introduces a modification of so-called predictive current control, by taking the control time delay into consideration. The results of simulation and experiment with a 10 kVA active power filter prototype show considerable improvement in current tracking capability, validating the proposed current control method.

  • PDF

A Study on LCMPPT controller for PV system (태양광 발전시스템을 위한 LCMPPT제어기에 관한 연구)

  • Kang, Tae-Kyung;Kho, Kang-Hoon;Choi, Seok-Won;Han, Ho-Dong;Lee, Hyun-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.680-683
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current-Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. Therefore, it is applied a small home power generation system that required many expenses. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF

Type I Error Rates and Power for Omnibus Tests of Repeated Measures Measn in the Split-Plot Design : F test, $\widetilde{\xi}$F test, and CIGA test

  • Kim, Hyunchul
    • Communications for Statistical Applications and Methods
    • /
    • v.4 no.1
    • /
    • pp.139-149
    • /
    • 1997
  • For split plot designs exact univariate F tests of the within-subjects main effect are based on the assumption of multisample sphericity. Type I error rates and power are reported for the F test and two tests designed for use when multisample sphericity is violated: the $\widetilde{\xi}$-adjusted test and the Corrected Improved General Approximation(CIGA) test.The results indicate that even though the F test and the $\widetilde{\xi}$-adjusted test have better power than the CIGA test in some conditions, the F test and the $\widetilde{\xi}$-adjusted test do not control Type I error rates when the design is unbalanced and the F test dose not have a good control of Type I error rates when sphericity assumption is severely violated.

  • PDF