• Title/Summary/Keyword: Power/Ground Noise

Search Result 172, Processing Time 0.027 seconds

Design of the Ground Resistance Measuring System to the Earth-Noise

  • Jung Min-Jae;Joo Hyung-Jun;Lee Ki-Hong;Oh Sung-Up;Jung Jae-Ki;Seong Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.566-570
    • /
    • 2001
  • Generally, grounding systems are responsible for the safe operation of a power system. Their performance guarantees equipment protection and personnel safety under condition of the limited ground potential rise and touch voltages as well as step voltages under ground fault conditions. Therefore, it is necessary to measure the ground resistance frequently for checking the performance of grounding system, In this paper the ground resistance measuring system using digital signal processor and high-performance L-C resonant band pass filter is presented. The signal current magnitude for measuring ground resistance in this system is $10^{-1}[A]\;to\;5\times10^{-2}[A]$ and the current frequency is 30[Hz].

  • PDF

A Study on a Shielding Effect of the Messenger Wires in Distribution Lines (배전선로에서의 조가선 차폐 효과 연구)

  • Kim, In-Soo;Han, Woong;Yeo, Sang-Min;Kim, Chul-Hwan;Weon, Bong-Ju;Lim, Yong-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems (측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정)

  • Lee, Bok-Hui;Eom, Ju-Hong;Kim, Seong-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.

eLoran Signal Strength and Atmospheric Noise Simulation over Korea

  • Rhee, Joon Hyo;Seo, Jiwon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.2
    • /
    • pp.101-108
    • /
    • 2013
  • GPS is the most widely-used Positioning, Navigation, and Timing (PNT) system. Since GPS is an important PNT infrastructure, the vulnerability of GPS to signal jamming has received significant attention. Especially, South Korea has experienced intentional high-power jamming from North Korea for the past three years, and thus realized the necessity of a complementary PNT system. South Korea recently decided to deploy a high-power terrestrial navigation system, eLoran, as a complementary PNT system. According to the plan, the initial operational capability of the Korean eLoran system is expected by 2016, and the full operational capability is expected by 2018. As a necessary research tool to support the Korean eLoran program, an eLoran performance simulation tool for Korea is under development. In this paper, the received signal strength, which is necessary to simulate eLoran performance, from the suggested Korean eLoran transmitters is simulated with the consideration of effective ground conductivities over Korea. Then, eLoran signal-to-noise ratios are also simulated based on atmospheric noise data over Korea. This basic simulation tool will be expanded to estimate the navigation performance (e.g., accuracy, integrity, continuity, and availability) of the Korean eLoran system.

Effect of the Signal-to-Noise Power Spectra Ratio on MTF Compensated EOC Images

  • Kang, Chi-Ho;Choi, Hae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.1
    • /
    • pp.43-52
    • /
    • 2003
  • EOC (Electro-Optical Camera) of KOMPSAT-1 (Korea Multi-Purpose SATellite) has been producing land imageries of the world since January 2000. After image data are acquired by EOC, they are transmitted from satellite to ground via X-band RF signal. Then, EOC image data are retrieved and pass through radiometric and geometric corrections to generate standard products of EOC images. After radiometric correction on EOC image data, Modulation Transfer Function (MTF) compensation is applicable on EOC images with user's request for better image quality. MTF compensation is concerned with filtering EOC images to minimize the effect of degradations. For Image Receiving and Processing System (IRPE) at KOMPSAT Ground Station (KGS), Wiener filter is used for MTF compensation of EOC images. If the Pointing Spread Function (PSF) of EOC system is known, signal-to-noise (SNR) power spectra ratio is the only variable which determines the shape of Wiener filter In this paper, MTF compensation in IRPE at KGS is briefly addressed, and MTF compensated EOC images are generated using Wiener filters with various SNR power spectra ratios. MTF compensated EOC images are compared with original EOC 1R images to observe correlations between them. As a result, the effect of SNR power spectra ratio on MTF compensated EOC images is shown.

Engineering Practice for ESS Protection by means of One Point Grounding System (일점접지방식을 이용한 전자교환기 방호의 실제)

  • Kim, Soo-Hyung;Seo, Jung-Uck
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.502-505
    • /
    • 1988
  • This paper is to demonstrate the effectiveness of one point grounding in support of ESS protection. One point grounding provides for the dispatching of excess energy for protection of switching equipment and personnel from lightning discharge hazards and for a natural sink for noise from atmospheric lightning and power transients. In most ESS installations there are a number of different items that must be maintained at a common ground potential for safety, fault protection or noise reduction. The items typically consist of power systems, heating and ventilating systems, distributing frames, repeating equipmets, switching equipments, etc. Grounding system of an ESS Office is most effective when all the ground points are connected to a single, common earth. The one point grounding prvides a common reference potential, keeping all the items of telecommunications facility free from the earth current and voltage hazards.

  • PDF

Low-Phase Noise Dual-band VCO Using PBG Structure (Photonic Bandgap 구조를 이용한 저 위상잡음 듀얼밴드 VCO에 관한 연구)

  • 조용기;서철헌
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.2
    • /
    • pp.53-58
    • /
    • 2004
  • In this paper, the low-phase dual-band VCO, by adding switching circuit with PIN diode at feedback loop of the oscillation part having negative-resistance, is realized. In order to reduce the phase noise of the VCO, PBG structure applied to the ground plane of the resonator. When applying for PBG structure, output power is -9.17㏈m and phase noise is -102㏈c/Hz at 5.25㎓, output power is -5.17㏈m and phase noise is -101㏈c/Hz at 1.8㎓, respectively.

Analysis of SMPS Characteristics applying Ground Plane Layer (Ground Plane레이어를 적용한 SMPS 특성분석)

  • Park, Jin-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.436-440
    • /
    • 2014
  • To verity the effect of PCB plane layer to the output characteristics of the Switched Mode Power Supply (SMPS), this paper compared with a generic one-layer PCB and a double-side PCB. This paper specially focused on the voltage, the current and the high frequency noise of the output characteristic of the SMPS, using a double-side PCB which has same layout and was installed a ground plane on the opposite side. This double-side PCB was assembled by all same components which used on the SMPS using the single-side PCB. The experiment results show the SMPS using the ground plan PCB can efficiently reduce the high frequency noise to 50mV at 100MHz from 150mV in the single-side PCB. And the results also show the high harmonics frequency was reduced as well.

A Novel Hexagonal EBG Power Plane for the Suppression of GBN in High-Speed Circuits (초고속 디지털 회로의 GBN 억제를 위한 육각형 EBG 구조의 전원면 설계)

  • Kim, Seon-Hwa;Joo, Sung-Ho;Kim, Dong-Yeop;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.199-205
    • /
    • 2007
  • In this paper, a novel hexagonal-shaped electromagnetic bandgap(EBG) power plane for the suppression of the ground bounce noise(GBN) in high-speed circuits is proposed. The proposed structure consists of hexagonal-shaped unit cells and detoured bridges connecting the unit cells. The hexagonal-shaped unit cells could omni-directionally suppress the GBN in digital circuits. The fabricated power plane's omni-directional -30 dB suppression bandwidth is from 330 MHz to 5.6 GHz. Then the proposed structure suppresses electromagnetic interference(EMI) caused by the GBN within the stopband. As a result, the proposed structure is expected to be conducive solving EMI problem in high-speed circuits.

Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise (고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터)

  • Lee, Sung-Ho;Kwon, Jung-Min;Kwon, Bong-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.