• 제목/요약/키워드: Potential Shock

Search Result 292, Processing Time 0.025 seconds

Analysis of the Electric Potential distribution and Evaluation of Electric Shock Risk in Bathtub (욕조에서의 전위분포 해석 및 전격재해 위험성 평가)

  • Kim, Chong-Min;Kim, Han-Sang;Jung, Jong-Wook;Jung, Jin-Soo;Kim, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.37-40
    • /
    • 2006
  • This paper presents the evaluation electric shock risk In bath so that we made and designed a bathtub which is the same size in real public bath. and then we did an experiment, provided of electric leakage in various conditions so, we measured how to form an electric potential and knew the electric potential is formed variously under exposed conductor in bath. also we made certain that electric shock risk is down if we insert an insulated pipe in bathtub pipe which is prevent from being formed the electric field sharply.

  • PDF

A Study on the Electric Shock due to Submerged Power Source (침수 상용전원에 의한 감전위험성 검토)

  • Jung, Jong-Wook;Jung, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.71-76
    • /
    • 2007
  • This paper describes a risk assessment of electric shock based on a experiment which demonstrates a submerged commercial power source. For the experiment a water tank was made and an outlet was installed on an interior wall. After filling the tank with a conductive water solution, the electric potential was measured with the distance, the direction from the power source, the conductivity and the level of the water solution. As a result, the potential distribution due to the outlet energized and exposed to the water solution depends on the distance from the submerged power source, however, the direction from the power source, the conductivity and the level of the water solution seemed to scarcely affected on the electrical shock risk.

Heat Shock Responses for Understanding Diseases of Protein Denaturation

  • Kim, Hee-Jung;Hwang, Na Rae;Lee, Kong-Joo
    • Molecules and Cells
    • /
    • v.23 no.2
    • /
    • pp.123-131
    • /
    • 2007
  • Extracellular stresses induce heat shock response and render cells resistant to lethal stresses. Heat shock response involves induction of heat shock proteins (Hsps). Recently the roles of Hsps in neurodegenerative diseases and cancer are attracting increasing attention and have accelerated the study of heat shock response mechanism. This review focuses on the stress sensing steps, molecules involved in Hsps production, diseases related to Hsp malfunctions, and the potential of proteomics as a tool for understanding the complex signaling pathways relevant to these events.

A Study on Development of the Hybrid Shock Absorber for Lunar Lander (달 착륙선 하이브리드 충격 흡수장치의 개발에 관한 연구)

  • Lee, Jaehyeong;Hwang, Jai-hyuk;Bae, Jae-sung;Lim, Jaehyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.81-86
    • /
    • 2012
  • The shock absorber is very important in various mechanical field. Without the shock absorber, the structure might be broken. For lunar lander, honeycomb shock absorber to absorber the shock by using plastic deformation of honeycomb has been used. It is cheap and simple to use but impossible using again without changing the honeycomb. The oleo-pneumatic type shock absorber is not able to use in the cosmos because it is vacuum and its temperature. This study suggests the hybrid shock absorber combined spring-ratchet mechanical shock absorber and eddy current electromagnetic damper. The ratchet restricts rebound of lunar lander and the spring converts the impact energy to the potential energy of the spring. The eddy current damper dissipates the impact energy by eddy current force without contact between the parts. This hybrid shock absorber is reusable while the honeycomb shock absorber isn't. The impact absorbing test of the hybrid shock absorber was carried out. This paper shows that the compared results the hybrid shock absorber with ratchet and without ratchet and evaluates the possibility of using for lunar lander.

  • PDF

A FE Transient Response Analysis of a Flexible Rotor-Bearing System with Mount System to Base Shock Excitation (마운트 시스템을 갖는 유연 로터-베어링 시스템의 기초전달 충격에 대한 유한요소 과도응답 해석)

  • Lee, An-Sung;Kim, Byung-Ok;Kim, Young-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.387-392
    • /
    • 2007
  • Turbomachinery such as turbines, pumps and compressors, which are installed in transportation systems such as warships, submarines and space vehicles, etc., often perform crucial missions and are exposed to potential dangerous impact environments such as base-transferred shock forces. To protect turbomachinery from excessive shock forces, it may be needed to accurately analyze transient responses of rotors, considering the dynamics of mount designs to be applied with. In this study a generalized FE transient response analysis model, introducing relative displacements, is firstly proposed to accurately predict transient responses of a flexible rotor-bearing system with mount systems to base-transferred shock forces. In the transient analyses the state-space Newmark method of a direct time integration scheme is utilized, which is based on the average velocity concept. Results show that for the identical mount systems considered, the proposed FE-based detailed flexible rotor model yields more reduced transient vibration responses to the same shocks than a conventional simple model or a Jeffcott rotor. Hence, in order to design a rotor-bearing system with a more compact light-weighted mount system, preparing against any potential excessive shock, the proposed FE transient response analysis model herein is recommended.

  • PDF

FE Modeling for the Transient Response Analysis of a Flexible Rotor-bearing System with Mount System to Base Shock Excitation (마운트 시스템을 갖는 유연 로터-베어링 시스템의 기초전달 충격 과도응답 해석을 위한 유한요소 모델링)

  • Lee, An-Sung;Kim, Byung-Ok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1208-1216
    • /
    • 2007
  • Turbomachinery such as turbines, pumps and compressors, which are installed in transportation systems, including aircrafts, ships, and space vehicles, etc., often perform crucial missions and are exposed to potential dangerous impact environments such as base-transferred shock forces. To protect turbomachinery from excessive shock forces, it may be needed to accurately analyze transient responses of their rotors, considering the dynamics of mount designs to be applied. In this study a generalized FE transient response analysis model, introducing relative displacements, is proposed to accurately predict transient responses of a flexible rotor-bearing system with mount systems to base-transferred shock forces. In the transient analyses the state-space Newmark method of a direct time integration scheme is utilized, which is based on the average velocity concept. Results show that for the identical mount systems considered, the proposed FE-based detailed flexible rotor model yields more reduced transient vibration responses to the same shocks than a conventional simple model, obtained by treating a rotor as concentrated lumped mass, equivalent spring and a damper or Jeffcott rotor model. Hence, in order to design a rotor-bearing system with a more compact light-weighted mount system, preparing against any potential excessive shock, the proposed FE transient response analysis model herein is recommended.

The Experimental Study on the Electric Potential Distribution by Electric Leakage in Street Lamp (가로등설비 누전시 전위분포에 대한 실험연구)

  • Park, Sang-Tae;Lee, Bok-Young;Hong, Sung-Ho;Choi, Chung-Suk;Gil, Hyung-Jun;Han, Woon-Ki
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.222-227
    • /
    • 2005
  • This paper presents study on the electric potential distribution when have a short in skeet lamp. In order to measure electric potential testing ground is built in. A experiment is conducted to simulate dry and submerged situation of street lamp. The street lamp is leaked by artificial means. And electric potential is measured in grounded street lamp and street lamp alone. The results show that touch voltage of grounded street lamp is possible to more high than street lamp alone. And the electric shock hazard is high because high electric potential is distributed near submerged street lamp. Also if street lamp is submerged ground is not useful to decrease electric shock hazard.

  • PDF

Shock Simulation and Experimental Verification of HDD (하드디스크 드라이브의 충격해석 및 실험적 검증)

  • Kim, Jin-Gon;Lee, Jae-Kon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2583-2588
    • /
    • 2009
  • This study deals with the shock response analysis of HDD subjected to a half-sine shock pulse and its experimental verification. Comparatively, accurate computer simulation allows designers to determine complete mechanical information during the product impact time period, compared with only segmental messages by sensors in a test, to predict potential failures. But, impact/shock simulation technology is rather sensitive to various factors to predict the shock behavior without validation. In our shock simulation, the methodology of analysis with LS-DYNA3D and test validation is adopted to predict the shock behavior of HDD. We can confirm the soundness of the present shock simulation through the comparison with electromagnetic shock test(200G/1ms) and linear drop test(300G/2ms).

The Effects of Urinary Trypsin Inhibitor on Hemorrhagic Shock (오줌 유래 Trypsin 억제제가 출혈성쇼크에 미치는 영향)

  • 권오경;김종민;이희천;정언승;양한석;변종환;송동호;조명행
    • Biomolecules & Therapeutics
    • /
    • v.5 no.3
    • /
    • pp.223-227
    • /
    • 1997
  • The protective effect of human urinary trypsin inhibitor(UTI) on acute hemorrhagic shock in beagle dog was studied. Hemorrhagic shock was experimentally induced in thoracotomized beagle dogs by removing blood and maintaining low arterial blood pressure for 30 min, and then blood removed was entirely transfused back into the dogs within one hour. When the blood was transfused, UTI was administered together to check the potential protective effect of UTI on hemorrhagic shock. The arterial blood pressure recovery was accelerated slightly by UTI treatment. Blood pH and $P_{a co2}$ returned to normal level in shorter time in the UTI treatment group. These data suggest that UTI may have protective effects on experimentally induced hemorrhagic shock.

  • PDF

Impact of External Temperature Environment on Large FCBGA Sn-Ag-Cu Solder Interconnect Board Level Mechanical Shock Performance

  • Lee, Tae-Kyu
    • Journal of Welding and Joining
    • /
    • v.32 no.3
    • /
    • pp.53-59
    • /
    • 2014
  • The mechanical stability of solder joints in electronic devices with Sn-Ag-Cu is a continuous issue since the material was applied to the industry. Various shock test methods were developed and standardized tests are used in the industry worldwide. Although it is applied for several years, the detailed mechanism of the shock induced failure mechanism is still under investigation. In this study, the effect of external temperature was observed on large Flip-chip BGA components. The weight and size of the large package produced a high strain region near the corner of the component and thus show full fracture at around 200G level shock input. The shock performance at elevated temperature, at $100^{\circ}C$ showed degradation based on board pad designs. The failure mode and potential failure mechanisms are discussed.