• Title/Summary/Keyword: Post-Hoc

Search Result 1,279, Processing Time 0.038 seconds

Statistical Analysis of Water Flow and Water Quality Data in the Imjin River Basin for Total Pollutant Load Management (임진강 유역 오염물질 총량관리를 위한 유량-수질 자료의 통계분석)

  • Cho, Yong-Chul;Choi, Hyeon-Mi;Lee, Young Joon;Ryu, Ingu;Lee, Myung-Gu;Gu, Donghoi;Choi, Kyungwan;Yu, Soonju
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.4
    • /
    • pp.353-366
    • /
    • 2018
  • The purpose of this study was assessment the quality of water by using the statistical analysis technique of the Water flow and water quality from January 2012 to December 2016 at the unit basin for total pollutant load management system (TPLMS) in the Imjin River. Water flow and water quality were monitored at an average of 8 day intervals, 11 parameters were used for correlation analysis, principal component analysis (PCA), factor analysis (FA), and cluster analysis (CA). The Hierarchical CA was classified into three according to the change of space, such as natural rivers, urban rivers, point with large influence of point pollution source, it was found that the type of contamination source the similarity of water quality affected the classification of cluster. Using one-way analysis of variance (ANOVA) and post-hoc Analysis, there were statistically significant differences between mean values among the clusters. Correlation analysis showed the correlation coefficient between $COD_{Mn}$ and TOC was 0.951 (p<0.01) and the correlation was statistically significantly higher. According to the result PCA and FA, 3 principal components can explaining 72% of the total variations in water quality characteristics and main factor was EC, $BOD_5$, $COD_{Mn}$, TN, TP and TOC indirect indicators of organic matter and nutrients were influenced. This study presented the regression equation obtained by applying the factor scores to the multiple linear regression analysis and concluded that the management Indirect indicators of organic matter and nutrients is important for water quality management in the Imjin River basin.

A Study on the Measurement of the Pollution Level of Bacteria and Disinfection of Table and IP Cassette (촬영 테이블과 IP Cassette의 세균 오염도 측정 및 소독에 관한 연구)

  • Bae, Seok-Hwan;Lee, Moo-Sik;Lim, Chang-Seon;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.229-237
    • /
    • 2008
  • Purpose : For the number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories, after identifying the bacteria before and after using alcohol and tissue including disinfectant and statistically testing, this research was intended to provide the basic data for the prevention and the right disinfection guideline for infection management of hospitals in diagnostic radiology. Subject and Method : The subject of this research was the general room of diagnostic radiology of a university hospital in Daejeon City. The research was conducted from Apr 5 to Apr 12, 2007. The number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories were tested before and after using alcohol and tissue for disinfection including disinfectant. In order to collect specimens exactly, they were collected with the nurse who specialized in infection management of the hospital, and statistical processing was done with SPSS V13.0. To compare the results before and after using alcohol and tissue, T-test was implemented, and post-hoc test was conducted. Results : Bacteria were detected in 19 cases of 24 subjects(79.2%), however, they were not detected in 5 cases(20.8%). 7kinds of bacteria were detected as isolated bacteria, of which Methicillin Resistant coagulase-negative Staphylococci(MRCNS) were detected in 15 cases(62.5%), which was most, Methicillin Resistant Staphylococcus Aureus(MRSA) in 6 cases(16.7%), Enterococcus Faecium(EFM) in 5 cases(20.8%), Acinetobacter baumannii(ABA) in 2 cases(8.3%), and Bacillus sp, Coagulase-negative Staphylococci(CNS), and Enterococcus sp(ENT) in 1 case, respectively(4.2%). In all bacteria except ABA, Gram positive bacillia were detected in 30 cases(97%), and Gram negative bacilli were detected only in 1 case(3%). As for the kinds of bacteria and the number of groups before and after using 70% Alcohol by Groups, when the bacteria were identified after disinfecting IP Cassette and Table with 70% Alcohol, all the bacteria became extinct in both IP Cassette and Table Group(100%). As for the kinds and number of bacteria before and after using Tissue Cleaner by Groups, the bacteria in Tissue Cleaner Group became completely extinct only in 10 Groups(71.2%), and in 4 Groups, there was much decrease in bacteria, however, they were still detected. The extinction rate of all the bacteria was 91.5%. That is, though the other bacteria became extinct(100%), that of MRCNS bacteria was lowest(83.6%), followed by MRSA(95%). Conclusion : As a result of comparing the mean of the bacteria which were detected before and after using 70% Alcohol and Tissue Cleaner, there was statistically significant in the significant level of 5% in both of them.

  • PDF

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

Effect of internal gap on retentivity in implant fixed prosthesis with lingual slot (설측 슬롯을 부여한 임플란트 고정성 보철물에서 내면 간격이 유지력에 미치는 영향)

  • Kim, Tae-Kyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.206-211
    • /
    • 2018
  • Purpose: Recently, a method of forming a slot in the prosthesis lingual has been introduced to solve the occlusal and aesthetic disadvantages of screw-retained prosthesis in the manufacture of implant-fixed prosthesis and to ensure retrievability in cement retained prostheses. The purpose of this study is to investigate the effect of the internal gap on the removal of the prosthesis in the preparation of cement-retained implant prostheses with lingual slots. Materials and methods: Titanium abutment and internal gap of the zirconia prosthesis to be attached to the upper part were set to 30, 35, and $50{\mu}m$, respectively. Three for each type total 15 were produced for each type. The zirconia prosthesis formed a retrievable cement-type slot with a space of 1 mm at the location where the titanium abutment meets the shelf area. Autocatalytic resin cement was used for bonding of abutment and zirconia prosthesis, and the maximum removal stress value was measured in units of Ncm by using the customized equipment of the cemented specimen. The Kruskal-Wallis test was used to compare the three groups by statistical analysis (${\alpha}=.05$), modified by post hoc test the Mann-Whitney U-test and the Bonferroni correction method were used to compare the two methods (${\alpha}=.017$). Results: There was no statistically significant difference in removal stress between the $30{\mu}m$ group and the $35{\mu}m$ group in the internal gap (P = .032), and there was a significant difference between the $30{\mu}m$ group and the $50{\mu}m$ group, between the $35{\mu}m$ group and the $50{\mu}m$ group (P < .017). Conclusion: Thus, the internal gap of computer-aided design affected the retention between the zirconia prosthesis and the titanium abutment.

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.

Effects of Foot Baths on Stress and exhaustion for high school senior students -A comparative study on the aroma oil and fermentation extract- (족욕이 수험생의 스트레스 및 피로에 미치는 효과 -아로마 오일과 발효추출물의 비교연구-)

  • Oh, Hee-Sun;Gang, Gyeong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.402-408
    • /
    • 2010
  • In the twenty first century, people experience a lot of stresses by psychological, social and environmental impetus. If the stress is excessive, it can become a problem and finally lead to diseases. Foot bath makes the body warm starting with the feet, controls the blood circulations and autonomic nervous systems. This study aims at examining the effects of stress and fatigue of senior students preparing for college entrance examination by foot bath with the aroma essential oil and the fermentation extracts. The experimental period was from March 30 to April 18, 2009. The study objects were 21 senior students of C Girls' High School in Cheonan. They were divided into 3 groups and treated 20 times. The first group was a foot bath group with Artemisia Herbal fermentation extracts. The second group was a foot bath group with the blending aroma essential oil of grapefruit, cypress and cedarwood. The third group was not treated. In the case of difference of physical and psychological stress, there was a reduction of 18.43 and 16.71 for the fermented extract group and 10.71 and 9.43 for the aroma group, while a reduction of 0.43 and 0.29 for the control group, respectively. This shows that foot baths using fermented extracts and aroma had lower physical stress compared to the control group (p<.01). For the difference of fatigue, there was a reduction of 19.14 for the fermented extract group, 11.57 for the aroma group and 0.07 for the control group, showing that foot baths accompanied by fermented extracts and aroma used in this study having lower fatigue compared to the control group (p<.01). The fermented extract group (M=55.71) had the highest level of satisfaction after foot baths, followed by the aroma group (M=49.14) and the control group (M=33.29). Duncan's post hoc test showed that there was a statistically considerable difference between the tests groups and control groups (p<.01). Through the results of this study, it was found that foot baths using bathing supplements were very effective for reducing stress and fatigue.

Alexithymia in Major Depressive Disorder and Subclinical Depression (주요 우울장애와 준임상적 우울증에서의 감정표현불능증)

  • Kim, Seog-Ju;Yu, Seung-Hee;Kim, Seong-Youn;Kim, Dong-Wook;Cho, In-Hee;Cho, Seong-Jin
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.15 no.2
    • /
    • pp.100-106
    • /
    • 2007
  • Objectives : The objective of the present study was to investigate alexithymia in major depressive disorder(MDD) and subclinical depression(SCD). Methods : Three hundred eighty-six community-dwelling adults(238 females and 148 males, age 19-79; mean age $43.0{\pm}13.9$) were recruited. Structured clinical Interview for DSM-IV(SCID) was conducted for the diagnosis of MDD or other Axis I psychiatric disorders. The Center for Epidemiological Studies for Depression Scale(CES-D) and the Totonto Alexithymia Scale(TAS) were administered to assess depressive symptom and alexithymia, respectively. Among subjects without MDD, those who had minor depressive disorder on the SCID or high scores(i.e. over 16) on the CES-D were defined as subjects with SCD. TAS total score and factor I, II, III scores of TAS in MDD, SCD, and non-depressive controls were compared. Results : Among 386 subjects, 38 subjects(9.8%) were diagnosed as MDD by DSM-IV criteria, while 57 subjects(14.8%) were classified into SCD group. There were significant differences between 3 groups(MDD, SCD and non-depressive controls) in total score($F_{2,383}=14.0$, p<0.01), factor I(difficulty in identifying feeling)($F_{2,383}=23.4$, p<0.01) and factor II(difficulty in describing feeling)($F_{2,383}=7.8$, p<0.01), but not factor III(external oriented thinking)($F_{2,383}=1.8$, p=0.16) of TAS. In post-hoc analysis, both MDD subjects and SCD subjects had higher scores in TAS total, factor I and factor II, compared to non-depressive controls(all p<0.01). In contrast, there were no significant differences between MDD subjects and SCD subjects in any TAS factor. Conclusion : In this study, both MDD subjects and SCD subjects were more alexithymic than non-depressive control subjects. These findings suggest that SCD, as well as MDD, is also related to alexithymia.

  • PDF

Effect of Fabric Sensor Type and Measurement Location on Respiratory Detection Performance (직물센서의 종류와 측정 위치가 호흡 신호 검출 성능에 미치는 효과)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Hyeok-Jae;Lee, Jeong-Hwan;Kwak, Hwi-Kuen;Ko, Yun-Su;Chae, Je-Wook;Oh, Su-Hyeon;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.22 no.4
    • /
    • pp.97-106
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the type and measurement location of a fabric strain gauge sensor on the detection performance for respiratory signals. We implemented two types of sensors to measure the respiratory signal and attached them to a band to detect the respiratory signal. Eight healthy males in their 20s were the subject of this study. They were asked to wear two respiratory bands in turns. While the subjects were measured for 30 seconds standing comfortably, the respiratory was given at 15 breaths per minute were synchronized, and then a 10-second break; subsequently, the entire measurement was repeated. Measurement locations were at the chest and abdomen. In addition, to verify the performance of respiratory measurement in the movement state, the subjects were asked to walk in place at a speed of 80 strides per minute(SPM), and the respiratory was measured using the same method mentioned earlier. Meanwhile, to acquire a reference signal, the SS5LB of BIOPAC Systems, Inc., was worn by the subjects simultaneously with the experimental sensor. The Kruskal-Wallis test and Bonferroni post hoc tests were performed using SPSS 24.0 to verify the difference in measurement performances among the group of eight combinations of sensor types, measurement locations, and movement states. In addition, the Wilcoxon test was conducted to examine whether there are differences according to sensor type, measurement location, and movement state. The results showed that the respiratory signal detection performance was the best when the respiratory was measured in the chest using the CNT-coated fabric sensor regardless of the movement state. Based on the results of this study, we will develop a chest belt-type wearable platform that can monitor the various vital signal in real time without disturbing the movements in an outdoor environment or in daily activities.

Shear bond strength of Universal bonding systems to Ni-Cr alloy (니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도)

  • Song, So-Yeon;Son, Byung-Wha;Kim, Jong-Yeob;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the shear bond strength between Ni-Cr alloy and composite resin using universal adhesive systems coMPared to conventional method using metal primers. Materials and methods: For this study, a total of 120 cast commercial Ni-Cr alloy (Vera Bond 2V) disks were embedded in acrylic resin, and their surfaces were smoothed with silicon carbide papers and airborne-particle abrasion. Specimens of each metal were divided into 6 groups based on the combination of metal primers (Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer) and universal adhesive systems (Single Bond Universal, All Bond Universal). All specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strength testing was performed with a universal testing machine at a cross head speed of 1 m/min. Data (MPa) were analyzed using one-way ANOVA and the post hoc Tukey's multiple comparison test (${\alpha}$=.05). Results: There were significant differences between Single Bond Universal, All Bond Universal, Metal Primer II and Alloy Primer, MKZ Primer, Metal & Zirconia Primer (P<.001). Conclusion: Universal Adhesive system groups indicated high shear bond strength value bonded to Ni-Cr alloy than that of conventional system groups using primers except Metal Primer II. Within the limitations of this study, improvement of universal adhesive systems which can be applied to all types of restorations is recommended especially non-precious metal alloy. More research is needed to evaluate the effect of silane inclusion or exclusion in universal adhesive systems.

MICROTENSILE BOND STRENGTH ACCORDING TO DIFFERENT DENTIN WALL POSITIONS AND CURING LIGHTS IN CLASS I CAVITY OF PRIMARY MOLAR (유구치 I급 와동에서 와동벽 위치와 중합광원에 따른 Microtensile Bond Strength 비교 연구)

  • Lee, Hyeon-Heon;Jang, Chul-Ho;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.62-72
    • /
    • 2007
  • The purpose of present study was to determine whether different kinds of curing lights can alter microtensile bond strength(MTBS) of class I cavity pulpal and axial wall specimens in primary molar. Thirty clean mandibular 2nd primary molar's occlusal enamel were removed and class I cavity, size of $2{\times}4{\times}2mm$ was prepared. Dentin bonding agent was applied according to manufacturer's manual. Each group was cured with Halogen Curing Unit, Plasma Curing Unit and LED Curing Unit. Composite resin was bulk filled and photo cured with same curing unit. MTBS specimens which size is $0.7{\times}0.7{\times}4mm$ were prepared with low speed saw. Specimens were coded by their curing lights and wall positions (Halogen - Axial wall group, Halogen - Pulpal wall group, Plasma - Axial wall group, Plasma - Pulpal wall group, LED - Axial wall group, LED - Pulpal walt group). MTBS were tested at 1 mm/min cross Head speed by Universal Testing Machine. Fractured surface and bonding surface was observed with SEM. T-test between axial and pulpal specimens in each curing lights, one-way ANOVA among different curing light specimens in each wall positions were done. Weibull distribution analysis was done. The results were as follows : Mean MTBS of pulpal wall specimens were significantly greater than that of axial wall specimens at each curing units(p<.05). There was no significant difference in the MTBS among three curing units at axial wall and pulpal wall. In Weibull distribution, pulpal wall specimens were more homogeneous than axial wall specimens.

  • PDF