• 제목/요약/키워드: Pollutant distribution

검색결과 295건 처리시간 0.025초

김해지방의 대기오염 특성 (Characteristics of Air Pollution at Kimhae)

  • 박종길;김종필;김지형
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.33-43
    • /
    • 1999
  • This paper aims to describe the characteristics of air pollution using air pollutants concentration and meteorological data observed at Kimhae from December 1996 to November, 1997. The results are as follows : The concentration distribution of sulfur dioxide($SO_2$), carbon monoxide(CO), particulate matter(PM-10), and nitrogen dioxide($NO_2$) is high during the late fall and winter and low during the summer, but ozone concentration is low during the winter season and high during summer season except Jangma period and these distributions appear to be closely connected with insolation and the number of clear day. Diurnal variation of concentrations for sulfur dioxide, particulate matter, and carbon monoxide are high during the rush hours and nighttime and low during the daytime and these variations are distinct toward the winter season. And diurnal variation of nitrogen dioxide concentration has also same pattern and these patterns are closely related to the increasing traffic volume at rush hours. Diurnal variation of ozone concentration is generally increase for daytime and decrease for the late afternoon and are closely related to the insolation and photochemical reaction. The 24 hour average concentrations of air pollutant observed at Kimhae represented a positive correlation and a negative correlation for $O_3$ and also a negative correlation for the meteorological elements such as wind speed and cloud cover.

  • PDF

환경에너지시설내 화격자식 소각로 수치해석 연구 (Numerical research for Gate Type Waste Incinerators In Environment energy facilities)

  • 김종윤;전용한
    • 대한안전경영과학회지
    • /
    • 제19권4호
    • /
    • pp.149-155
    • /
    • 2017
  • This study is analyzed combustion phenomena based on the environmental energy facility incinerator. It is assumed that combustible components of waste are composed of carbon and hydrogen, and the combustion process of fuel is by setting as multi-component / multistage reaction. As the combustion chamber is burned, the high temperature environment is achieved, also the heat transfer accompanied by the turbulent flow and the generation of NOx, a pollutant, are interpreted to predict the thermal and fluid characteristics and pollution emissions of the grate incinerator. As the result of internal flow analysis, the slow flow around the ash chute and the mixing effect due to the complicated turbulence around the combustion chamber were predicted to show excellent performance. It is shown to the internal average temperature was about $1024^{\circ}C$, around the about $1000^{\circ}C$ homogeneous temperature distribution. Due to the sudden temperature decrease in the boiler, the flue gas temperature at the outlet was estimated to be about $220^{\circ}C$.

어자원 보호육성을 위한 생육환경 개선에 관한 연구- I - 소형저인망에 채집된 진해만 저서어류의 분포 - (Studies on the Growth and Environmental Development for the Protection-Nourishment of Fisheries Resources - 1. Distribution of Demersal Fishes in the Chinhae Bay. Korea -)

  • 김삼곤;김종화;박창두
    • 수산해양교육연구
    • /
    • 제11권1호
    • /
    • pp.98-113
    • /
    • 1999
  • Demersal fishes as second study for the protection-nourishment of fisheries resources in Chinhae Bay were analysed using fish samples collected by a small otter trawler at bimonthly-interval from August, 1997 to June, 1998. Of the 55 species identified, Hexagrammos otakii, Pleuronichthys cornutus, Leiognathus nuchalis, Thrissa koreana, Callionymous lunatus, Acanthogobius flavimanus and Trachurus japonicus predominated in abundance. Especially, Hexagrammos otakii, Pleuronichthys cornutus and Leiognathus nuchalis were always collected at anywhere around a year in the bay. The seasonal fluctuation of number of species is very large as the ranging from 14 species in August to 25, December. The diversity index of individual number and biomass by month and station is 0.68(February)~1.13(October), 0.38(February)~1.06(October) respectively. The indices above mean that the number of species were not distributed broadly over the bay and also concentrated in several species only owing to the local pollutant extent.

  • PDF

금호강 유역에서의 4-nitrophenol 배출 특성과 오염원 기여도 모의 연구 (Study on the simulation of emission characteristics and sources contribution of 4-nitrophenol in the Geumho River)

  • 박경덕;양득석;이인정;김일규
    • 상하수도학회지
    • /
    • 제33권1호
    • /
    • pp.43-53
    • /
    • 2019
  • In the Geumho River, 4-nitrophenol has been detected, thus it is necessary to investigate the contamination sources in order to prevent the release of this compound. However, the research to estimate the potential source is regarded as complicated research. In this study, the distributions of 4-nitrophenol were simulated and the contribution of the potential sources was estimated using a numerical model(HydroGeoSphere; HGS) and the measuring data of 4-nitrophenol from 2013 to 2017. The altitude data, the land cover data, the flow rates of the tributaries and wastewater treatment plants, and the decay rate of 4-nitrophenol was used as the input data. The results of this research showed that the contribution rates of potential contamination sources in the upstream area were higher than that of the downstream area. Most of the upstream area is the agricultural area, it seemed that 4-nitrophenol was originated from the pesticides. In order to achieve more specific location of sources, an intensive investigation in the upstream is required.

전해 산화제에 의한 악취 원인 VOCs 제거 특성 (Characteristics of odorous VOCs removal by using electrolytic oxidant)

  • 이태호;류희욱
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.381-388
    • /
    • 2018
  • In this study, various conditions and phenomena that occur in the process of removing odorous VOCs by using electrolyzed oxidant were examined. The formation of hypochlorous acid, which is an oxidant produced by electrolysis, was investigated and the properties of the oxidizing agent used to decompose toluene, xylene, and cyclohexane were investigated. As a result, it was found that the production rate and the final concentration of the oxidizing agent increased with the current density. It was found that the degree of removal varies depending on the property of each pollutant. Interestingly, in the batch experiments in which the pH of the produced oxidant was controlled, it was found that the degree of elimination varied depending on the pH of the substance. These results suggest that the difference in the concentration and distribution of hypochlorous acid (HOCl) and hypochlorite ($OCl^-$) due to the pH change leads to the difference in oxidizing power on the oxidation characteristics of each substance. Styrene and terpineol showed better degradation characteristics than toluene and xylene in odorous VOC removal experiments by spraying electrolytic oxidant using a lab-scale continuous reactor. In conclusion, the removal of odorous VOCs by the electrolytic oxidant can have various applications in that it can oxidize pollutants of various spectra.

식품표면에 부착된 미세먼지의 정량법 (An automated determination method of particulate matter on food surface)

  • 박선영;방봉준;임다영;정동화;이동언
    • 식품과학과 산업
    • /
    • 제54권1호
    • /
    • pp.29-33
    • /
    • 2021
  • Particulate matter (PM) is an air pollutant that causes serious environmental problems in Korea and other countries. The annual average PM10 concentration in Korea is around 40 ㎛/㎥, which is more than twice as high as the WHO recommended standard. When consumed with food, fine PM can pose a risk to humans. However, the risk of fine PM has been focused on the risk of fine PM introduced through the respiratory system. We investigated the quantitative measuring methods of PM10 on food surface to identify possible risk analysis of fine PM. The surfaces of food with artificially contaminated PM10 were observed with a scanning electron microscope(SEM). An automatic object-based image analysis was used to analyze the amount and size distribution of particulate matter contained in SEM micrographs.

산업단지 및 주거지역에 대한 환경대기 중 주요 악취물질의 농도특성에 관한 연구 - 안산시 반월공단을 중심으로 - (Odorous Pollutant Concentration Levels in the Ban-Wall Industrial Area and Its Surrounding Regions)

  • 최여진;김기현;전의찬
    • 한국지구과학회지
    • /
    • 제27권2호
    • /
    • pp.209-220
    • /
    • 2006
  • 본 연구에서는 악취민원이 빈발한 경기도 안산시에 위치한 반월공단의 주거지역과 공단지역 등을 중심으로 주요 관리대상으로 설정된 악취성분들에 대한 환경대기 중 농도분포 특성을 2년여 기간동안 6차례에 걸쳐 조사하였다. 이들의 거동을 이해하기 위해, 시간적(오전과 오후) 및 공간적(공단 내외부의 위치) 기준으로 분포특성에 대한 비교를 시도하였다. 그 결과, 오전시간대에 비해 오후시간대에 고농도 분포가 현저하게 높은 것으로 나타났다. 이와 유사하게 공간적인 기준으로 비교한 결과도 공단 내부에서 관측한 결과에서 대부분의 성분들이 고농도를 유지하는 것을 확인할 수 있었다. 본 연구의 결과는 안산시 주변 및 공단지역의 환경대기 중에 존재하는 악취성분들이 시간적 및 공간적 기준으로 다양한 분포특성을 취한다는 것을 보여주었다.

낙동강 하구지역의 식물플랑크톤 극대역 변동에 관한 수직시뮬레이션 -II. 식물플랑크톤 극대역 변동의 수치시뮬레이션- (The numerical simulation on variation of phytoplankton maximum region in the estuary of Nakdong river -II. The numerical simulation on variation of phytoplankton maximum region-)

  • 이대인
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.375-384
    • /
    • 2000
  • It is very important to interprete and simulate the variation of phytoplankton maximum region for the prediction and control of red tide. This study was composed of two parts first the hydrodynamic simulation such as residual current and salinity diffusion and second the ecological simulation such as phytoplankton distribution according to freshwater discharge and pollutant loads. Without the Nakdong river discharge residual current was stagnated in inner side of this estuary and surface distribution of salinity was over 25psu. On the contrary with summer mean discharge freshwater stretched very far outward and some waters flowed into Chinhae Bay through the Kadok channel and low salinity extended over coastal sea and salinity front occurred. From the result of contributed physical process to phytioplankton biomass the accumulation was occurred at the west part of this estuary and the Kadok channel with the Nakdong river discharge. When more increased input discharge the accumulation band was transported to outer side of this estuary. The frequently outbreak of red tide in this area is caused by accumulation of physical processes. The phytoplankton maximum region located inner side of this estuary without the Nakdong river discharge and with mean discharge of winter but it was moved to outer side when mean discharge of the Nakdong river was increased. The variation of input concentration from the land loads was not largely influenced on phytoplankton biomass and location of maximum region. When discharge was increased phytoplankton maximum region was transferred to inner side of the Kadok channel. ON the other hand when discharge was decreased phytoplankton maximum region was transferred to inner side of this estuary and chlorophyll a contents increased to over 20$\mu\textrm{g}$/L Therefore if any other conditions are favorable for growth of phytoplankton. decreas of discharge causes to increase of possibility of red tide outbreak.

  • PDF

아산만해역 어류체내와 퇴적물중의 PCB와 유기염소계농약 분포 (On the Distribution of PCBs and Organochlorine Pesticides in Fish and Sediment of the Asan Bay)

  • 최진영;이성규;방재현;양동범;홍기훈;신경훈
    • Ocean and Polar Research
    • /
    • 제33권1호
    • /
    • pp.45-53
    • /
    • 2011
  • Distribution of Polychlorinated biphenyls (PCBs) and organochlorine pesticides in sediments, seawater and fish tissues were examined. Concentrations of ${\Sigma}PCBs$ and ${\Sigma}DDTs$ in the intertidal sediments of Asan Bay ranged from $1.90{\sim}3.27\;ng\;g^{-1}$ dw (dry weight) and $0.51{\sim}1.26\;ng\;g^{-1}$ dw, respectively. ${\Sigma}PCBs$ concentrations in the tissue of greenling (Hexagrammos otakii), olive flounder (Paralichthys olivaceus) and finespotted flounder (Pleuronichthys cornutus) were $1.27{\pm}0.55$, $1.30{\pm}0.71$ and $1.19{\pm}0.43\;ng\;g^{-1}$ ww (wet weight), respectively. The profile of PCBs in the sediments and the 3 species of fish differed as witnessed by the dominance of tetra- to penta-chlorinated congeners in sediments while penta- to hexa-chlorinated congeners dominated in fish. ${\Sigma}DDTs$ concentrations were $0.67{\pm}0.52$, $0.79{\pm}0.61$, $1.58{\pm}1.05\;ng\;g^{-1}$ ww respectively in the tissue of greenling, olive flounder and finespotted flounder. The p,p'-DDE appeared to be the most important metabolite of DDT in studied fishes. The concentrations of PCBs and organochlorine pesticides measured in this study for fish were generally lower than those of previous studies. Compared to the pollutant concentration quality guidelines in marine fish, the environment of Asan Bay appears to be in a healthy state.

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • 유통과학연구
    • /
    • 제17권7호
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.