• Title/Summary/Keyword: Plate and screw

Search Result 182, Processing Time 0.026 seconds

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

Two Part Triplane Fracture with Extention through Medial Malleolus (Four Cases Report) (족관절 내과를 침범한 두 부분 삼면 골절(4예 보고))

  • Cha, Seung-Do;Kim, Hyung-Soo;Chung, Soo-Tae;Yoo, Jeong-Hyun;Park, Jai-Hyung;Kim, Joo-Hak;Kim, Yong-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.179-183
    • /
    • 2009
  • The triplane fracture has been described as a fracture of the distal tibial epiphysis occurring across three planes-sagittal, transverse and coronal. The characteristic pattern of fusion of distal tibial epiphysis explains the special configuration of the fragments in the triplane fracture. According to Dias-Tachdjian classification, triplane fracture is classified two part fracture, three part fracture, four part fracture and two part fracture with extension to the medial malleolus. Among four types, two part triplane fracture with extension to the medial malleolus is a relatively rare injury and generally is not treated by closed reduction. Such fractures should have an anatomic reduction and adequate fixation to restore the joint congruity and obtain an anatomic reduction of the growth plate to prevent a future growth deformity. This is usually best accomplished with an open reduction and screw fixation or k-wire fixation. We experienced two part triplane fracture with extension to medial malleolus and check the CT to define the extent of the injury completely. And then we underwent open reduction and screw fixation for the fracture. As a result, we present four cases of two part triplane fracture with extension with review of related literatures.

  • PDF

Orthognathic surgery for patients with fibrous dysplasia involved with dentition

  • Udayakumar, Santhiya Iswarya Vinothini;Paeng, Jun-Young;Choi, So-Young;Shin, Hong-In;Lee, Sung-Tak;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.37.1-37.7
    • /
    • 2018
  • Background: Fibrous dysplasia (FD) is characterized by the replacement of normal bone by abnormal fibro-osseous connective tissue and typically treated with surgical contouring of the dysplastic bone. When dysplastic lesions involve occlusion, not only is surgical debulking needed, orthognathic surgery for correction of dentofacial deformity is mandatory. However, the long-term stability of osteotomized, dysplastic bone segments is a major concern because of insufficient screw-to-bone engagement during surgery and the risk of FD lesion re-growth. Case presentation: This case report reviewed two patients with non-syndromic FD that presented with maxillary occlusal canting and facial asymmetry. Le Fort I osteotomy with recontouring of the dysplastic zygomaticomaxillary region had been performed. The stability of osseous segments were favorable. However, dysplastic, newly formed bone covered the previous plate fixation site and mild bony expansion was observed, which did not influence the facial profile. Including the current cases, 15 cases of orthognathic surgery for FD with dentition have been reported in the literature. Conclusion: The results showed that osteotomy did not appear to significantly reduce the long-term stability of the initial fixation insufficiency of the screw to the dysplastic bone. However, based on our results and those of the others, long-term follow-up and monitoring are needed, even in cases where the osteotomized segment shows stable results.

Fatigue Characterization of Glass/Polypropylene Composite Bone Plates Locked with an Artificial Tibia under Moisture Environment (인조골에 체결된 유리섬유/폴리프로필렌 복합재료 고정판의 수분 환경 피로 특성)

  • Han, Min-Gu;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.26 no.5
    • /
    • pp.328-333
    • /
    • 2013
  • In this study, bone plate made of glass/polypropylene composite material which was applied to an artificial bone was tested to check the service ability under fatigue loading. To check serviceability of composite bone plates fatigue test was carried out considering changes in the moisture absorption rate, locking position of screws and loading condition. Test results showed that all the tested specimens had the fatigue life more than one million cycles which was much higher fatigue life than the expected value of 650,000 cycles. Screw position was not critical impact on the deformation of the fracture site. In this paper, the mechanical performance of the glass/polypropylene composite was verified by fatigue test under various water absorption conditions, and this result may give useful information on the design of composite bone plate.

The Analysis of the Treatment Outcomes of Proximal Humeral Fractures with Locking Plates

  • Lee, Kwang-Won;Hwang, Yoon-Sub;Kim, Choon-Myeon;Yang, Dae-Suk;Park, Tae-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • Background: The aim of this study was to assess the clinical outcomes after treatment of proximal humeral fractures with locking plates, and to determine which factors influence the clinical and radiological outcomes. Methods: Fifty six patients who were treated with locking plates for proximal humeral fractures and had been followed for more than 1 year were enrolled in this study. We performed functional evaluation using the Constant score and analyzed radiographic results. The following factors that may potentially influence the clinical outcomes were assessed: age, gender, type of fracture, presence of medial metaphyseal comminution, bone mineral density, anatomical reduction, restoration of medial mechanical support, and postoperative complications. Results: The mean Constant score was 70.1 points at the final follow-up. Female gender, 4-part fractures, AO type-C fractures, and fractures with medial metaphyseal comminution were associated with a poor clinical outcome. On the other hand, restoration of medial mechanical support and accurate anatomical reduction had a positive influence on clinical outcomes. Postoperative complications resulted in 3 patients (intra-articular screw perforation: 1 patient, varus deformity with screw loosening: 1 patient, nonunion: 1 patient). Conclusions: When treating proximal humeral fractures with locking plate fixation, following factors: a female gender, Neer type 4-part fracture, AO type C fracture, and medial metaphyseal comminution are important risk factors that surgeons should take into consideration. Factors that contribute to better clinical outcomes of operative treatment for humeral fractures are accurate anatomical reduction and restoration of medial mechanical support.

Effective Reduction of the Frontal Process of the Maxillary Fracture Segment Using Intermaxillary Fixation Screw (악간고정용 스크류를 이용한 위턱뼈 이마돌기 골절편의 효과적인 정복)

  • Moon, Suk-Ho;Lee, Woo-Sung;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae;Oh, Deuk-Young
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.555-558
    • /
    • 2011
  • Purpose: It is relatively unusual that infraorbital rim fracture is accompanied by nasal bone fracture. In order to correct effectively, subciliary approach and intranasal manipulation are applied simultaneously. But if reduction is not successful, intranasal manipulation may become aggressive and this often causes complications. We introduce a method using intermaxillary fixation screws for decreasing such complications and effective reduction of fracture. Methods: Total seven patients with fracture of frontal process of maxilla were treated with this method. The fracture site was exposed through the subciliary approach, and one or two screws were inserted into the displaced fracture fragment. During the traction of the screws using the wire, the fracture fragment was pushed upward from the intranasal side using an elevator supplementarily and fixed with a plate and the screws. Results: In all patients, the fracture fragment was reduced successfully and no complication occurred during one year's postoperative follow-up. Conclusion: When reduction cannot be attained through a bone hook or an elevator alone, reduction of fracture fragment can be done easily using intermaxillary fixation screws. This method is less likely to cause a mucosal injury because intranasal manipulation is not aggressive. Furthermore, as the screw can be inserted and removed easily, this method is considered effective not only for fracture of frontal process of maxilla but also for fractures in other regions.

Arthroscopic Cannulated Screw Fixation Technique for Avulsion Fracture of the Intercondylar Eminence of the Tibia (삽관 나사못(Cannulated screw)을 사용한 경골 과간 융기부 견열 골절의 관절경적 치료 기법)

  • Lee, Kee-Byoung;Chang, Ho-Guen;Lee, Seok-Beom;Moon, Young-Wan;Kang, Ki-Hoon;Lee, Wook-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.127-131
    • /
    • 1999
  • Avulsion fractures of the intercondylar eminence of the tibia are not uncommon. In the displaced avulsion fracture, anatomical reduction and firm fixation of fracture fragments are needed but the most of the conventional operative techniques including arthroscopic technique are relatively complex and need. The results were not always satisfactory due to the risk of postoperative complications such as wound infection, premature epiphyseal closure and loss of fixation after early motion etc. So we describe a simple and safe modified method of arthroscopic reduction and fixation for avulsion fractures of the intercondylar eminence of the tibia. In our thirteen cases, we achieved anatomical reduction and secure fixation using cannulated screw through the three arthroscopic portals (anterolateral, medial mid-patellar and central). Postoperatively, immediate limited range of motion of the knee and partial weight bearing were possible. Additional use of the washer afforded safe fixation of comminuted avulsion fracture. The advantage of this technique includes its technical simplicity, easy removal of hardware, ability to treat comminuted type IV fracture with washer, no additional skin incision, no damage to growing plate in growth children and less morbidity.

  • PDF

Cephalometric evaluation of skeletal stability and pharyngeal airway changes after mandibular setback surgery: Bioabsorbable versus titanium plate and screw fixation

  • Phu Hnin Thet;Boosana Kaboosaya
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.181-190
    • /
    • 2024
  • Purpose: This study compared sequential changes in skeletal stability and the pharyngeal airway following mandibular setback surgery involving fixation with either a titanium or a bioabsorbable plate and screws. Materials and Methods: Twenty-eight patients with mandibular prognathism undergoing bilateral sagittal split osteotomy by titanium or bioabsorbable fixation were randomly selected in this study. Lateral cephalometric analysis was conducted preoperatively and at 1 week, 3-6 months, and 1 year postoperatively. Mandibular stability was assessed by examining horizontal (BX), vertical (BY), and angular measurements including the sella-nasion to point B angle and the mandibular plane angle (MPA). Pharyngeal airway changes were evaluated by analyzing the nasopharynx, uvula-pharynx, tongue-pharynx, and epiglottis-pharynx (EOP) distances. Mandibular and pharyngeal airway changes were examined sequentially. To evaluate postoperative changes within groups, the Wilcoxon signed-rank test was employed, while the Mann-Whitney U test was used for between-group comparisons. Immediate postoperative changes in the airway were correlated to surgical movements using the Spearman rank test. Results: Significant changes in the MPA were observed in both the titanium and bioabsorbable groups at 3-6 months post-surgery, with significance persisting in the bioabsorbable group at 1 year postoperatively (2.29°±2.28°; P<0.05). The bioabsorbable group also exhibited significant EOP changes (-1.21±1.54 mm; P<0.05) at 3-6 months, which gradually returned to non-significant levels by 1 year postoperatively. Conclusion: Osteofixation using bioabsorbable plates and screws is comparable to that achieved with titanium in long-term skeletal stability and maintaining pharyngeal airway dimensions. However, a tendency for relapse exists, especially regarding the MPA.

PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT (인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석)

  • Park, Sang-Kyu;Lee, Baek-Soo;Engelke, W;Kim, Boo-Dong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.

Preventing Varus Deformity in Senile Patients with Proximal Humerus Fractures and Poor Medial Support

  • Kim, Young-Kyu;Kang, Suk-Woong;Kim, Jin-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.216-222
    • /
    • 2016
  • Background: We investigated the effectiveness of fibular strut allograft augmentation of proximal humerus fractures to prevent varus deformity in patients over the age of 65 years with insufficient medial support. Methods: We analyzed the clinical and radiological outcomes of locking plate fixation with adjunct fibular strut allograft augmentation in 21 patients with proximal humeral fractures. The inclusion criteria were age (65-year-old or older); presence of severe medial comminution; inadequate medial support; and those who could participate in at least a one year follow-up. The average age was 76.4 years. We analyzed each patient's Constant score, our indicator of clinical outcome. As radiological parameters, we analyzed time-to-bone union; restoration of the medial hinge; difference between the immediately postoperative and the last follow-up humeral neck-shaft angles;; and anatomical reduction status, which was assessed using the Paavolainen method. Results: A successful bone union was achieved in all patients at an average of 11.4 weeks. We found that the average Constant score was 74.2, showing a satisfactory outcome. The average difference in the humeral neck-shaft angles between the immediately postoperative time-point and at the final follow-up was $3.09^{\circ}$. According to the Paavolainen method, the anatomical reduction was rated excellent. The medial hinge was restored in 14 of 21 patients. Although we did not find evidence for osteonecrosis, we found that a single patient had a postoperative complication of screw cut-out. Conclusions: Fibular strut allografting as an adjunct treatment of proximal humeral fractures may reduce varus deformity in patients with severe medial comminution.