DOI QR코드

DOI QR Code

Cephalometric evaluation of skeletal stability and pharyngeal airway changes after mandibular setback surgery: Bioabsorbable versus titanium plate and screw fixation

  • Phu Hnin Thet (Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University) ;
  • Boosana Kaboosaya (Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University)
  • Received : 2023.12.14
  • Accepted : 2024.03.23
  • Published : 2024.06.30

Abstract

Purpose: This study compared sequential changes in skeletal stability and the pharyngeal airway following mandibular setback surgery involving fixation with either a titanium or a bioabsorbable plate and screws. Materials and Methods: Twenty-eight patients with mandibular prognathism undergoing bilateral sagittal split osteotomy by titanium or bioabsorbable fixation were randomly selected in this study. Lateral cephalometric analysis was conducted preoperatively and at 1 week, 3-6 months, and 1 year postoperatively. Mandibular stability was assessed by examining horizontal (BX), vertical (BY), and angular measurements including the sella-nasion to point B angle and the mandibular plane angle (MPA). Pharyngeal airway changes were evaluated by analyzing the nasopharynx, uvula-pharynx, tongue-pharynx, and epiglottis-pharynx (EOP) distances. Mandibular and pharyngeal airway changes were examined sequentially. To evaluate postoperative changes within groups, the Wilcoxon signed-rank test was employed, while the Mann-Whitney U test was used for between-group comparisons. Immediate postoperative changes in the airway were correlated to surgical movements using the Spearman rank test. Results: Significant changes in the MPA were observed in both the titanium and bioabsorbable groups at 3-6 months post-surgery, with significance persisting in the bioabsorbable group at 1 year postoperatively (2.29°±2.28°; P<0.05). The bioabsorbable group also exhibited significant EOP changes (-1.21±1.54 mm; P<0.05) at 3-6 months, which gradually returned to non-significant levels by 1 year postoperatively. Conclusion: Osteofixation using bioabsorbable plates and screws is comparable to that achieved with titanium in long-term skeletal stability and maintaining pharyngeal airway dimensions. However, a tendency for relapse exists, especially regarding the MPA.

Keywords

Acknowledgement

This research was supported by the Chulalongkorn University Graduate Scholarship Program for ASEAN and Non-ASEAN Countries.

References

  1. Kasahara K, Shin M, Katou Y, Koyachi M, Sugahara K, Bessho H, et al. Clinical study on removal of metal osteosynthesis material after orthognathic surgery. Int J Oral Med Sci 2021; 20: 175-83. 
  2. Luo M, Yang X, Wang Q, Li C, Yin Y, Han X. Skeletal stability following bioresorbable versus titanium fixation in orthognathic surgery: a systematic review and meta-analysis. Int J Oral Maxillofac Surg 2018; 47: 141-51. 
  3. Park YW. Bioabsorbable osteofixation for orthognathic surgery. Maxillofac Plast Reconstr Surg 2015; 37: 6. 
  4. On SW, Cho SW, Byun SH, Yang BE. Bioabsorbable osteofixation materials for maxillofacial bone surgery: a review on polymers and magnesium-based materials. Biomedicines 2020; 8: 300. 
  5. Haas Junior OL, Guijarro-Martinez R, de Sousa Gil AP, da Silva Meirelles L, Scolari N, Munoz-Pereira ME, et al. Hierarchy of surgical stability in orthognathic surgery: overview of systematic reviews. Int J Oral Maxillofac Surg 2019; 48: 1415-33. 
  6. Shin JH, Kim MA, Park IY, Park YH. A 2-year follow-up of changes after bimaxillary surgery in patients with mandibular prognathism: 3-dimensional analysis of pharyngeal airway volume and hyoid bone position. J Maxillofac Surg 2015; 73: 340.e1-9. 
  7. Tseng YC, Hsiao SY, Cheng JH, Hsu KJ, Chen CM. Postoperative skeletal stability and pharyngeal airway: counterclockwise versus clockwise rotation during mandibular setback surgery. Biomed Res Int 2020; 2020: 3283080. 
  8. Sahoo NK, Agarwal SS, Datana S, Bhandari SK. Effect of mandibular setback surgery on tongue length and height and its correlation with upper airway dimensions. J Maxillofac Oral Surg 2021; 20: 628-34. 
  9. Landes CA, Ballon A, Tran A, Ghanaati S, Sader R. Segmental stability in orthognathic surgery: hydroxyapatite/poly-l-lactide osteoconductive composite versus titanium miniplate osteosyntheses. J Craniomaxillofac Surg 2014; 42: 930-42. 
  10. Chanachol P, Chongruangsri NN, Arunjaroensuk S, Rochanavibhata S, Siriwatana K, Pimkhaokham A. Comparative study of stability between two different fixation systems after orthognathic surgery in mandibular prognathism skeleton. J Stomatol Oral Maxillofac Surg 2023; 124: 101431. 
  11. Park YW, Kang HS, Lee JH. Comparative study on long-term stability in mandibular sagittal split ramus osteotomy: hydroxyapatite/poly-l-lactide mesh versus titanium miniplate. Maxillofac Plast Reconstr Surg 2019; 41: 8. 
  12. Sukegawa S, Kanno T, Katase N, Shibata A, Takahashi Y, Furuki Y. Clinical evaluation of an unsintered hydroxyapatite/poly-l-lactide osteoconductive composite device for the internal fixation of maxillofacial fractures. J Craniofac Surg 2016; 27: 1391-7. 
  13. Rao SH, Selvaraj L, Lankupalli AS. Skeletal stability after bilateral sagittal split advancement and setback osteotomy of the mandible with miniplate fixation. Craniomaxillofac Trauma Reconstr 2014; 7: 9-16. 
  14. Ueki K, Moroi A, Yoshizawa K, Hotta A, Tsutsui T, Fukaya K, et al. Comparison of skeletal stability after sagittal split ramus osteotomy among mono-cortical plate fixation, bi-cortical plate fixation, and hybrid fixation using absorbable plates and screws. J Craniomaxillofac Surg 2017; 45: 178-82. 
  15. Enacar A, Aksoy AU, Sencift Y, Haydar B, Aras K. Changes in hypopharyngeal airway space and in tongue and hyoid bone positions following the surgical correction of mandibular prognathism. Int J Adult Orthodon Orthognath Surg 1994; 9: 285-90. 
  16. On SW, Han MW, Hwang DY, Song SI. Retrospective study on change in pharyngeal airway space and hyoid bone position after mandibular setback surgery. J Korean Assoc Oral Maxillofac Surg 2015; 41: 224-31. 
  17. Choi SK, Yoon JE, Cho JW, Kim JW, Kim SJ, Kim MR. Changes of the airway space and the position of hyoid bone after mandibular set back surgery using bilateral sagittal split ramus osteotomy technique. Maxillofac Plast Reconstr Surg 2014; 36: 185-91. 
  18. Kim H, Lee KC. Sequential changes in pharyngeal airway dimensions after mandibular setback surgery and its correlation with postsurgical stability in patients with mandibular prognathism. J Oral Maxillofac Surg 2021; 79: 2540-7. 
  19. Eppley BL. Bioabsorbable plate and screw fixation in orthognathic surgery. J Craniofac Surg 2007; 18: 818-25. 
  20. Stanton DC, Liu F, Yu JW, Mistretta MC. Use of bioresorbable plating systems in paediatric mandible fractures. J Craniomaxillofac Surg 2014; 42: 1305-9. 
  21. Singh M, Singh RK, Passi D, Aggarwal M, Kaur G. Management of pediatric mandibular fractures using bioresorbable plating system - efficacy, stability, and clinical outcomes: our experiences and literature review. J Oral Biol Craniofac Res 2016; 6: 101-6. 
  22. Rha EY, Paik H, Byeon JH. Bioabsorbable plates and screws fixation in mandible fractures: clinical retrospective research during a 10-year period. Ann Plast Surg 2015; 74: 432-6. 
  23. Joss CU, Vassalli IM. Stability after bilateral sagittal split osteotomy setback surgery with rigid internal fixation: a systematic review. J Oral Maxillofac Surg 2008; 66: 1634-43. 
  24. Hoffmannova J, Foltan R, Vlk M, Klima K, Pavlikova G, Bulik O. Factors affecting the stability of bilateral sagittal split osteotomy of a mandible. Prague Med Rep 2008; 109: 286-97. 
  25. Mobarak KA, Krogstad O, Espeland L, Lyberg T. Long-term stability of mandibular setback surgery: a follow-up of 80 bilateral sagittal split osteotomy patients. Int J Adult Orthodon Orthognath Surg 2000; 15: 83-95. 
  26. de Villa GH, Huang CS, Chen PK, Chen YR. Bilateral sagittal split osteotomy for correction of mandibular prognathism: long-term results. J Oral Maxillofac Surg 2005; 63: 1584-92.