• Title/Summary/Keyword: Plastic tube

Search Result 385, Processing Time 0.025 seconds

The Effects of Aprotinin Addition and Plastic Tube Usage for Glucagon Test Results (Glucagon 검사시 Aprotinin 첨가와 Plastic tube 사용이 미치는 영향)

  • Cho, Youn-Kyo;Choi, Sam-Kyu;Seo, So-Yeon;Shin, Yong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.117-120
    • /
    • 2011
  • Purpose: There are 3 warnings for Glucagon tests. First, EDTA tubes that already contain Aprotinin must be used for plasma collection. Second, for freezer storage of centrifuged plasma, glass tubes must be used. Last, glass tubes must be used for testing procedure. So we compared the glucagon results of next 3 situation to those of control group. First, We compared to results by tubes without Aprotinin and with aprotinin. Second, we compared to results by tubes(plastic vs glass) for plasma storage. Third, we compared to results by tubes(plastic vs glass) for testing. We tried to evaluate the results of the 3 different condition. Materials and Methods: 40 healthy adults were studied with normal results on the general medical check up and laboratory tests. We compared the results of 3 different condition belows: Blood were collected in EDTA tube containing aprotinin and plasma was stored in the glass tube for 3 days in a freezer and results were obtained by tests in the glass tubes. Results from EDTA plasma without aprotinin, results from platic tubes for freezer stroage, results from plastic tube when testing. Simple linear regression analysis and paired t-test using SPSS were done for statistical analysis. Commercial glucagon kit(RIA-method)which made by Siemens company were used. Results: Correlation coefficient between results of EDTA tubes with Aprotinin vs without Aprotinin was r=0.783 (p=0.064). Result of specimen in plastic tubes stored 3 days in a freezer showed lower value compared to those in glass tube(r=0.979, p=0.005). Also, results of testing in plastic tubes showed lower values than those testing in glass tubes. (r=0.754, p<0.001). Conclusion: It is recommended for glucagon determination to use EDTA tube with Aprotinin which is a inhibitor of protein breakdown enzyme. Results of plastic tube when storage and testing showed lower value than those of glass tubes, so it is recommended to store and test in glass tubes.

  • PDF

A Study on the Post Deformation According to an Environmental Temperature of the Plastic Fuel Tube for Automobile (자동차용 플라스틱 연료튜브의 환경온도에 따른 후변형에 관한 연구)

  • Park, J.S.;Moon, C.Y.;Jeong, Y.D.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.56-60
    • /
    • 2003
  • Recently the plastic fuel tube is usually used to reduce production cost and weight in automobiles. These days, material used to plastic fuel tube is the polyamide12. The fuel tube is made of the PA12. Post deformation of the tube has been changed by environmental temperature. So, it is important to prevent post deformation. The experiment is performed to investigate post deformation of the tube produced by each bending process. In this study, the results we obtained are used to bending process system for post deformation as the environmental temperature of the tube. It turned out that the method of steam heating and air cooling was shown less deformation than other methods.

  • PDF

Study on the Plastic Buckling of Thin Rectangular Tubes under Compression (압축하중을 받는 박판 4각튜브의 소성좌굴 연구)

  • Kim, C.W.;Han, B.K.;Kim, J.M.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.357-362
    • /
    • 2000
  • In the present paper the plastic buckling of thin-walled rectangular tube is analyzed. The stress-strain relations of the plates of the tube are idealized into nonlinear material of Ramberg and Osgood. Computing elastic moduli of the nonlinear material a precise plastic buckling stress has determined. The plastic buckling stress of the wider plate of the tube is considered as the crippling strength of the tube. The present theory is in good agreement with the experiments in various thickness-width ratios and materials.

  • PDF

Effect of the yield criterion on the strain rate and plastic work rate intensity factors in axisymmetric flow

  • Lyamina, Elena A.;Nguyen, Thanh
    • Structural Engineering and Mechanics
    • /
    • v.58 no.4
    • /
    • pp.719-729
    • /
    • 2016
  • The main objective of the present paper is to study the effect of the yield criterion on the magnitude of the strain rate and plastic work rate intensity factors in axisymmetric flow of isotropic incompressible rigid perfectly plastic material by means of a problem permitting a closed-form solution. The boundary value problem consisting of the axisymmetric deformation of a plastic tube is solved. The outer surface of the tube contracts. The radius of the inner surface does not change. The material of the tube obeys quite a general yield criterion and its associated flow rule. The maximum friction law is assumed at the inner surface of the tube. Therefore, the velocity field is singular near this surface. In particular, the strain rate and plastic work rate intensity factors are derived from the solution. It is shown that the strain rate intensity factor does not depend on the yield criterion but the plastic work rate intensity factor does.

Heat Transfer Characteristics of Plastic Particle Slurry in a Circular tube Flow (관내 유동 플라스틱 슬러리의 열전달 특성)

  • 김명환;김명준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.451-456
    • /
    • 2004
  • This present experimental study has dealt with the heat transfer characteristics of plastic particle slurry which flows in a circular tube. This type of slurry is suggested for heat transfer enhancement effect cause by random and vortex effect of plastic particle dispersed in water. As a result, the thermal boundary layer becomes thin so the heat transfer coefficient on the tube wall more increase compare to pure water flow. This experimental test section was composed with stainless pipe which has the length of 2000mm, inner pipe diameter of 14mm and outer pipe diameter of 60mm. The most effective and important parameter of this experiment is plastic packing factor(PPF). The focuses of these results are pressure drop and heat transfer coefficient. As results, the friction factor of plastic particle slurry becomes higher at laminar flow region than pure water because of buoyancy effect of plastic particle but the local heat transfer coefficient becomes higher.

Spring Back on the Compound Bending of the Plastic Fuel Tube for Automobile (자동차용 플라스틱 연료튜브의 복합 벤딩에 대한 스프링백)

  • Moon, C.Y.;Park, J.S.;Jeong, Y.D.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.51-55
    • /
    • 2003
  • Recently the requirements for light weight and high performance of the automobile have increased. Especially, the plastic fuel tube makers have made their efforts to dove]op the various plastic fuel tube module with not only dimensional accuracy but also cost competitiveness. The experiment is performed to investigate spring backs for PA12 plastic fuel tubes in case of compound bending. In the experiment, steam bending process is adopted as bending method. In this study, the results we obtained are used to design the bending fixtures and the compound bending system.

  • PDF

Effects of Plastic Deformation on Surface Properties and Microstructure of Alloy 690TT Steam Generator Tube (증기발생기 전열관 Alloy 690TT의 소성변형이 표면특성 및 미세조직에 미치는 영향)

  • Soon-Hyeok Jeon;Ji-Young Han;Hee-Sang Shim;Sung-Woo Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.20 no.1
    • /
    • pp.16-24
    • /
    • 2024
  • Denting of steam generator (SG) tube is defined as the reduction in tube diameter due to the stresses exerted by the corrosion products formed on the outer diameter surface. This phenomenon is mostly observed in the crevices between SG tube and the top-of tubesheet or tube support plate. Despite the replacement of SG tube with Alloy 690, which has better corrosion resistance than Alloy 600, the denting of SG tube still remains a potential problem that could decrease the SG integrity. Deformation of SG tube by denting phenomenon can affect the surface properties and microstructure of SG tube. In this study, the effects of plastic deformation on surface properties and microstructure of Alloy 690 thermally treated (TT) tube was investigated by using the various analysis techniques. The plastic deformation of Alloy 690 increased the surface roughness and area. Many surface defects such as ripped surface and micro-cracks were observed on the deformed Alloy 690TT specimen. Based on the electron backscatter diffraction analysis, the dislocation density of deformed SG tube increased compared to non-deformed SG tube. In addition, the effects of changes in surface properties and microstructure of SG tube on general corrosion behavior were discussed.

An Analytical Investigation on the Ultimate Strength of Concrete-Filled Steel Tube Columns using Elasto-Plastic Large Deformation Analysis (탄소성 대변형 해석을 이용한 콘크리트 충전강관(CFT) 기둥의 극한강도에 관한 해석적 연구)

  • Jang, Gab-Chul;Chang, Kyong-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.6
    • /
    • pp.69-74
    • /
    • 2007
  • Recently, to improve performance and strength of circular steel columns, application of concrete-filled steel tube(CFT) type are gradually increased. To accurately predict the plastic design of concrete-filled steel tube columns, a plasticity model is required which can be describe large deformation behavior of concretes and steels. In this study, elastic-plastic large deformation analysis is developed by using the plasticity model of structural steels, and accurate and validity of the developed program is verified by comparing between the experiment and the analysis for concrete-filled steel tube column. In concrete-filled steel tube columns, influence of initial deflection on ultimate strength behavior is investigated by using developed program.

  • PDF

Numerical Analysis of Responses of a Elasto-plastic Tube under Kerosene-air Mixture Detonation (케로신-공기 혼합물의 비정상연소 모델과 탄소성 관의 동적 거동 수치해석)

  • Lee, Younghun;Gwak, Min-cheol;Yoh, Jai-ick
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.169-172
    • /
    • 2015
  • This paper presents a numerical investigation on kerosene-air mixture detonation and behaviors of thermal elasto-plstic thin metal tube under detonation loading based on multi-material analysis. The detonation loading is modeled by the kerosene-air mixture detonation which is compared with CJ condition and experimental cell size. And the thermal softening effect on elasto-plstic model of metal tube is indicated by different dynamic response of detonation loaded tube in various temperature and tube thickness.

  • PDF

Comparison of Glass CTAD Tube and Plastic Sodium Citrate Tube for Coagulation Test (혈액응고 검사용 유리 CTAD 채혈관와 플라스틱 Sodium Citrate 채혈관의 비교)

  • Kang, Su-Jin;Park, Jeong-Su;Song, Yoon-Kyung;Kong, Sun-Yong;Lee, Do-Hoon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.3
    • /
    • pp.156-160
    • /
    • 2007
  • We evaluated the newly developed plastic sodium citrate tubes for routine coagulation test by direct comparison with glass citrate theophylline adenosine dipyridamole (CTAD) tubes. Blood was drawn from 100 patients into glass CTAD tubes and plastic sodium citrate tubes. After collection, samples were centrifuged at 1500 ${\times}$g for 15 min at $22^{\circ}C$. Prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen were measured by using the Coagrex-800 (IRC, Japan). We used comparison plot by linear regression model and difference plot graphs to compare the results of the independent measurements of PT, aPTT, fibrinogen between glass CTAD tubes and plastic sodium citrate tubes. On the comparison study between glass CTAD tubes and plastic sodium citrate tubes, the correlation coefficients (R) were 0.99 for PT, 0.97 for aPTT and 0.97 for fibrinogen. This results implicated good correlation of each parameter between two tubes. Although the difference plot graph analysis showed statistically significant differences between glass and plastic tubes for PT, aPTT and fibrinogen, the range of difference was acceptable according to the CLSI/NCCLS guideline. The plastic sodium citrate tubes showed good correlation with the glass CTAD tubes, so it can substitute glass citrate tube for routine coagulation tests.

  • PDF