A Study on Filed Application of Electro-Osmosis Soil Improvement Method with Nano-Coated Plastic Drain Baord (나노 코팅된 PDB를 이용한 동전기 지반개량 공법의 현장 적용성에 관한 연구)

  • Ahn, Sangro;Ahn, Kwangkuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.10
    • /
    • pp.5-11
    • /
    • 2018
  • The PBD (Plastic Board Drain) method is one of effective ground improvement methods on the soft dredging reclamation ground. This method has outstanding economic efficiency and constructability, and it is widely used for the soft ground improvement. However, the PBD method reduces permeability and drainage capacity of the ground due to the long construction period. Therefore, the nano coated Plastic drain board (PDB) was developed to solve problems. It is the non-metallic electrode and improves the weakness of the PBD method by using electric force of the electro-osmosis method. Various researches have been conducted to apply the nano coated PDB, but these researches were limited to model tests in laboratory. In this study, model and field tests were conducted to assess field applicability of the nano coated PDB. The result showed that the nano coated PDB had the better effect on the ground improvement compared to the normal PDB.

The Application to the New Drain Materials for Soft Ground Improvement (연약지반 개량을 위한 신배수재의 적용성에 관한 비교 실험)

  • 김병일;이동현;양상호;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.761-766
    • /
    • 2003
  • In environmental and economical views Plastic Board Drain(PBD) has many problems which is generally used in improving soft grounds. In order to improve these, Rags drain and Sponge drain are developed in this study, and the application to drains is presented though comparing with PDB and Sand drain In consolidation effects. Test results show that the consolidation effects, including consolidation rate and stregth, increase in order of Sand and Rags, PDB and Sponge drain.

  • PDF

Soil Improvement using Vertical Natural Fiber Drains (연직천연섬유배수재를 이용한 연약지반 개량)

  • Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.4
    • /
    • pp.37-45
    • /
    • 2008
  • A pilot test using environmentally friendly drains, was carried out to evaluate their applicability potential in the field. The pilot test site was divided into 5 different areas, with several combinations of vertical and horizontal drains installed for evaluation. Conventional natural fiber drains (FDB), new developed straw drain board (SDB) and plastic drain board (PDB) were used as vertical drains, while sand and fiber mats were used as horizontal drains. Surface settlement rates and excess pore pressure generation/dissipation tendency of PDB and FDB are almost identical except those of SDB. Cone tip resistance obtained from cone penetration test measured at the end of 1st consolidation stage for upper soft layer definitely increased irrespective of types of vertical drains. The monitoring and site investigation test data obtained at the pilot test site prove the vertical natural fiber drains can be used as substitutes of conventional plastic and sand material.

  • PDF

A Pilot Test of Various Vertical Drains and its Initial Monitoring Results (다양한 연직배수재의 시험시공 및 초기현장 계측)

  • Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.2
    • /
    • pp.45-50
    • /
    • 2006
  • Although the discharge capacity of the natural fiber drains are very low compared to that of plastic drain board (PDB), it is found that the conventional fiber drains and the new developed straw drain boards have great potential for use as a substitute for conventional plastic drain boards through several model tests. To verify their field application, a pilot test using environmentally friendly drains is also being carried out to prove their effective discharge capacity in the field. The pilot test site was divided into 5 different areas, with various combinations of vertical and horizontal drains installed for evaluation. Definite characteristics of various drains are still to be found due to the delay in construction of embankment. Consolidation behavior of three types of vertical drains and two types of horizontal drains will be analyzed after the completion of the embankment in the near future.

  • PDF

Finite element analysis for the difference of displacement behavior developed from suction drain method and vertical drain method (Suction 연직배수 공법과 PDB 공법의 변위거동 차이에 대한 유한 요소 해석)

  • Kim, Ki-Nyeon;Ahan, Dong-Wook;Han, Sang-Jae;Jung, Seung-Yong;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1165-1172
    • /
    • 2006
  • In this study, an aspect of settlement, developed from different ground improvement method like suction drain method using vacuum pressure and vertical drain method using overburden pressure, was compared each other. In order to analyze settlement tendency of each method exactly, the finite element analysis program was used. The analyses of vertical settlement and lateral displacement for suction drain method and vertical drain method were conducted independently during the solving stage. The initial condition of drainage zone was fixed with 25m depth and 21m width. After the program analyses, the settlement condition had a different tendency with the ground improvement method. Especially, in the results of vertical drain method, the disparity of settlement between the middle of improved zone and unimproved zone. In the case of suction drain method, however, the difference of settlement was smaller than that of vertical drain method.

  • PDF

중금속으로 오염된 사격장토의 동전기 정화 -실내 파일롯 실험 중심으로-

  • 한상재;김병일;이정철;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.69-72
    • /
    • 2003
  • The purpose of this study is the development of hybrid horizontal electrokinetic(EK) remediation system on rifle range soil under unsaturated conditions. In order to remediate soil polluted by multi-species heavy metals, in pi]of scale, a series of EK remediation tests are carried out. PVC and PDB(Plastic Drain Board) electrode systems that connected with the power supply of constant voltage and vacuum pressure of 0.5kgf/$\textrm{cm}^2$ are installed, The test results showed that the pH distribution in the sample is below 8, which is maintained until the test is finished, because of the injection of flushing solution. The final concentration, which is normalized by initial concentration, is ranged about 50 to 90%.

  • PDF

Improvement Effect and Electrical Characteristics of Soft Ground with Plastic Electrode Spacing (전극간 거리에 따른 연약지반의 지반개량 효과와 전기적 특성)

  • Byeon, Inseong;Kang, Hongsig;Sun, Seokyoun;Han, Jeonghoon;Ahn, Kwangkuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Soft ground stabilization is needed to construct large civil facilities on the soft clay ground. Pre-loading method, which is accelerating consolidation method, is generally used to stabilize the soft ground. However, pre-loading method is required long construction period and quantities of fill material. Therefore, electro-osmosis method is used to replace pre-loading method for stabilizing the soft ground. Electro-osmosis method is disadvantageous in constructive and economic aspects because it is needed a metallic electrode. So, in order to solve the those disadvantages, plastic electrode was developed to replace metallic electrode. Plastic electrode, which is made by using nano-technology on existing Plastic Drain Board (PDB), was used to supply the electric power. In this study, therefore, the model test was conducted to confirm the effect of improvement and electrical characteristics of soft ground by spacing of plastic electrode. The result shows that the effect of improvement of soft ground was decreased up to 45% by increasing electrode spacing and electrical characteristics on the soft ground were influenced by consolidation settlement with electrode spacing.

Study of the Influence of Mandrels on the Smear Zone and the Variation of Permeability (스미어존 형성과 투수성 변화에 미치는 멘드럴의 영향에 관한 연구)

  • Kim, Su-Sam;Jang, Yeon-Su;Go, Gyeong-Hwan
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.45-58
    • /
    • 1997
  • In this paper the factors developing ground disturbance with the penetration of PDB mandrels are analysed by using field reconnaissance and laboratory test. In the laboratory tests, the amount of smear zones around the PDB mandrels is compared with respect to the shape and the size of mandrels by penetrating model mandrels of various shapes into the reconstituted clay. The shapes of mandrels selected are circular, oval and rectangular. It was recognized from the field reconnaissance that the size and shape, driving techniques of mandrels, as well as the size and shape of anchor shoe could develop ground disturbance. The mandrels that would reduce the smear effect of clay is oval and rectangular shapes rat her than circular one. It was found that the smear effect becomes smaller as the ratio of the long and short edge of the rectangular shape mandrel becomes larger.

  • PDF