Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant (원자력발전소 직류전원계통용 축전지 성능시험 분석)

  • Kim, Daesik;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

The effect of plant spacing on several agronomic traits of a soybean variety under the tropical environment (열대환경하에 있어서 대두재식밀도가 각종형질에 미치는 영향)

  • Kwon, Shin-Han;Quyen, Nguyen H.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.7 no.1
    • /
    • pp.133-137
    • /
    • 1969
  • This experiment was conducted to determine the optimum row width and plant spacing within row under the tropical environment for a leading soybean variety Palmetto and it was carried out at Eakmat Experiment Station in Vietnam. The experiments were arranged in a split plot design with four replications and the test was repeated twice in two years. Variations for seed yield due to the distance between rows were significant at 1 per cent level in 1967 test(dry season growing) and at 5 per cent level in 1968 test. Significant differences for plant height, lodging, maturity, number of branches per plant, and number of pods per plant due to the row width were not found in both tests, while significant differences in difference spacing within row was found in all traits studied. Interaction between width of row and spacing within row for seed yield and plant height were found at five percent level in 1967 test. These results indicate that close planting may increase in seed yield and plant height in both seasons, and decrease in loadging. From these studies, one could be understood that the plant population, particularly in dry season, plays decisive roles on seed yield in soybean culture, and the maximum plant height and minimum value of lodging index were also observed in closest spacing plots. The highest soybean yield in late planting would be expected by a combinations of 30 cm(between rows)${\times}$5cm(between hills) plot, while 40cm ${\times}$ 5cm planting method would be suggested for rainy season growing. Highest seed yield was obtained at closet spacing in both dry and rainy season, and these results led to drilling method in seeding where about 20 seeds per meter of row could be recommended. Besides the seed yield, the close planting may produce some advantages, such as increase plant height and decrease lodging, weeds and erosion of surface soil.

  • PDF

Evaluation on diagnostic efficiency of the standard tube agglutination test for bovine brucellosis (소 브루셀라병 표준시험관응집반응법 진단효율 평가)

  • Sung, So-Ra;Kim, Ji-Yeon;Her, Moon;Lee, Kichan;Gu, Jeong-Hui;Kang, Sung-Il;Lee, Hyang-Keun;Kim, Suk-Mi;Jung, Suk-Chan
    • Korean Journal of Veterinary Service
    • /
    • v.35 no.4
    • /
    • pp.269-273
    • /
    • 2012
  • A confirmatory serological test, the standard tube agglutination test (STAT) is evaluated for the diagnostic efficiency in brucellosis Korea. A total of 345 bovine samples were collected from regional veterinary branch under national brucellosis monitoring program from January 2010 to June 2012 in Korea. These samples were diagnosed as suspected serum and brucellosis positive by the Rose Bengal test (RBT) and the STAT, respectively. The STAT was compared and evaluated with three serological test such as the indirect-enzyme linked immunosorbent assay (I-ELISA), competitive-enzyme linked immunosorbent assay (C-ELISA) and fluorescence polarisation assay (FPA) prescribed for international trade by OIE. Among the 345 bovine serum samples, 302 (87.5%) were diagnosed as positive in the STAT, while 215 (62.3%), 223 (64.6%) and 194 (56.2%) serum samples were diagnosed as positive for brucellosis in the I-ELISA, C-ELISA and FPA, respectively. The STAT showed quite high positive results as compared with three prescribed tests of OIE. FPA, I-ELISA and C-ELISA have shown 60.6%, 64.9% and 67.2% correlation, respectively as compared to the STAT. However correlations of three prescribed tests ranged high 84.1~97.7%. Especially, correlation between I-ELISA and C-ELISA is quite high, 97.7%. These results suggest that the STAT has shown many false-positive reactions. Therefore, additional serological test, such as ELISAs and FPA, would be necessary to adopt as a confirmatory test in the national surveillance program of bovine brucellosis in Korea.

Development of Automatic Data Acquisition & Remote Diagnostic System for Improving Efficiency of High-Voltage Motors Off-Line Insulation Diagnostic Test (고압전동기 Off-Line 절연진단시험 효율개선을 위한 데이터자동취득 및 원격진단시스템 구축)

  • Kang, Sang-Mu;Kang, Dae-Jeong;Han, Hyun-Seok;Kim, Won-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.707-708
    • /
    • 2015
  • This paper proposes a method for improving efficiency of high-voltage motors off-line insulation diagnostic test. The conventional manual test method has measurement errors and excessive processing time. We developed the KITAS system and solved these problems by using the instrument remote control and communication technology. The result of proficiency testing by interlaboratory comparisons using Power Factor Tip-Up test was '${\mid}E_n{\mid}$ < 1'. It was possible to confirm the validity of acquired data from the KITAS and establish a remote diagnostic system for easy access without physical limitations.

  • PDF

Research on the on-site Seat Test Technology for the nuclear safety related valves (원전용 안전등급 밸브의 현장 폐쇄기밀시험 기술에 대한 연구)

  • Jung Hwan Seok;Kim Tae Sung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.8-17
    • /
    • 2021
  • The seat leakage test is required after the maintenance work on the valve seat. Either the test has been performed outside of the plant after cutting the valve from the pipe system or the simplified test has been performed so far. It was unable to perform the test at the plant site because it is hard to make a steady pressure on the valve inlet when it is installed in the pipe. This research aims to perform the leakage test in the nuclear power plant while it is installed in the pipe system. The mock-up test is performed by pressurizing the leak-off pipe on the valve body. The result is compared with traditional test result by pressurizing the valve inlet. Furthermore the chamber mock-up tests are performed under various conditions. The leak rate by the developed test using the leak-off pipe is found to be similar but greater than the leak rate by the existing test method. It implies that the test using the leak-off pipe is more conservative than the existing test. The methodology and the equipment which this paper suggests that on-site seat test is possible and the application of the technology could reduce the time and cost for the valve maintenance work significantly.

Loss of a Main Feedwater Pump Test at 100% Power Simulation using Korean Standard Nuclear Plant Analyzer (KSNPA)

  • Jeong, Won-Sang;Kim, Shin-Whan;Sung, Kang-Sik;Seo, Jong-Tae;Lee, Sang-Keun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.296-302
    • /
    • 1996
  • The Loss of a Main Feedwater Pump test at 100% Power for YGN 4 was simulated in order to verify and validate the KSNPA. The comparison of the test data with the KSNPA prediction results showed reasonable agreement in the trends of the major plant parameters. All plant control systems including NSSS and T/G control systems are properly actuated and stabilized the plant conditions to a new steady state conditions in the KSNPA. From the comparison results, the KSNPA showed its capability to simulate the LOMFP event for the Korean Standard Nuclear Power Plant.

  • PDF

Nutrient Utilisation and Growth Performance of Broiler Rabbits Fed Oat Plant Meal and Tall Fescue Hay

  • Bhatt, R.S.;Sharma, S.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.9
    • /
    • pp.1228-1232
    • /
    • 2001
  • Forty five Soviet Chinchilla rabbits weaned at 35 d of age were fed 5 experimental diets prepared by using oat plant meal ($T_2,\;T_4$) and tall fescue hay ($T_3,\;T_5$) at 25% and 50% level along with control ($T_1$). The gain in body weight at 84 d of age decreased with test material substitution, however, the differences were non significant when compared with oat plant meal and were significant (p<0.05) with tall fescue hay at both the levels. Feed conversion ratio also deteriorated with test material and its increasing proportion and the differences were significant (p<0.05). The performance-index calculated were 42.1, 36.7, 29.4, 33.3 and 18.8 in $T_1,\;T_2,\;T_3,\;T_4$ and $T_5$, respectively. Digestibility of all the organic nutrients decreased significantly (p<0.05) with test material incorporation, as a result nutritive value of the test diets decreased linearly. Nitrogen balance as per cent of intake was higher in oat plant meal substituted diet compared to tall fescue substituted diet. Cost per kg live weight gain was lowest with 50% oat plant meal followed by 25% oat plant meal incorporation. It was highest with tall fescue hay substitution. Nutritive value of oat plant meal as calculated was DCP 5.1%, TDN 35.8% and that of tall fescue hay was DCP 6.5%, TDN 30.8%. Thus, oat plant meal can be substituted safely up to 25% in the feeding regime of weaner rabbits whereas, for tall fescue hay the safe limit is below 25% level and needs to be ascertained.

The Improvement of Flocculation Basin in Water Treatment Process (정수처리공정에서 플록형성지의 효율향상 연구)

  • Gang, Chang-Ho;Lee, Hyeon-Dong;Yu, Jae-O
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.3
    • /
    • pp.231-240
    • /
    • 2001
  • The problem of the flocculation basin was induced by installing the pilot plant using tracer test at Yang-Duck water treatment plant in Pohang cite. The flocculation basin model downscaled as 1/20 was made of acryl and evaluated hydraulically by transforming the section of the effluent in the flocculation basin. The optimum section of the effluent was suggested and applied to the plant. The efficiency of the flocculation basin according to improvement was evaluated by the particle counter which can count the number of particles each size fraction. The results of this study are as follows : First, it was desirable to make the retention time as short as possible because the flow and the index value were similar regardless of the retention time. Second, after the modification in Yang-Duck water treatment plant, the problem of destruction of floe was improved and the plant was operated satisfactorily. The hydraulic experiment with tracer test can be applied to the performance evaluation as well as improvement of facility in unit process of existing water treatment plant. Additionally, it can be used to find a design factor in the new water treatment plant.

  • PDF

Seismic performance of emergency diesel generator for high frequency motions

  • Jeong, Young-Soo;Baek, Eun-Rim;Jeon, Bub-Gyu;Chang, Sung-Jin;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1470-1476
    • /
    • 2019
  • The nuclear power plants in South Korea have been designed in accordance with the U.S. Regulatory Guide 1.60 (R.G 1.60) design spectrum of which the peak frequency range is 2-10 Hz. The characteristics of the earthquakes at the Korea nuclear power plant sites were observed to be closer to that of Central and Eastern United States (CEUS) than the R.G 1.60, which is a lower amplification in a low frequency range, and a higher amplification in a high frequency range. The possibility of failure for sensitive power plant components in the high frequency range has been considered and evaluated. In this study, in order to improve the reliability of nuclear plant and administrative control procedures, seismic tests of an emergency diesel generator (EDG) were conducted using a shaking table under both high and low frequency ranges. From the tests, oil/lubricant leaks from the bolt connections, the fuel filter and the fuel inlet were observed. Therefore, the check list of nuclear plant components after an earthquake should include bolt connections of EDG as well as anchor bolts.

Load Test Simulator Development for Steam Turbine-Generator System of Nuclear Power Plant

  • Jeong, Chang-Ki;Kim, Jong-An;Kim, Byung-Chul;Choi, In-Kyu;Woo, Joo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1384-1386
    • /
    • 2005
  • This paper focuses on development of load test simulator of a steam turbine-generator in a nuclear power plant. When load is taken off from electrical power network, it is very difficult to effectively control the steam flow to turbine of the nuclear turbine-generator, because of disturbances, such as electrical load and network unbalance on electrical network. Up to the present time, the conventional control system has been used for the load control on nuclear steam generator, owing to the easy control algorithms and the advantage which have been proven on the nuclear power plant. However, since there are problems with stability control during low power and start-up, only a highly experienced operator can operate during those procedures. Also, a great deal of time and an expensive simulator is needed for the training of an operator. The KEPRI is developed simulator for 600MW nuclear power plant to take a test of generator load rejection, throttle valve, and turbine load control. Total load test is implemented before start up.

  • PDF