• Title/Summary/Keyword: Plane of motion

Search Result 785, Processing Time 0.034 seconds

Optimal Design of 3D Printer based Piezo-driven Vertical Micro-positioning Stage (3D 프린터 기반 수직형 마이크로 모션 스테이지의 최적설계)

  • Kim, Jung Hyun
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.1
    • /
    • pp.78-85
    • /
    • 2017
  • This paper presents the development of a 3D printer based piezo-driven vertical micro-positioning stage. The stage consists of two flexure bridge structures which amplify and transfer the horizontal motion of the piezo-element into vertical motion of the end-effector. The stage is fabricated with ABS material using a precision 3D printer. This enables a one-body design eliminating the need for assembly, and significantly increases the freedom in design while shortening fabrication time. The design of the stage was optimized using response surface analysis method. Experimental results are presented which demonstrate 100nm stepping in the vertical out-of-plane direction. The results demonstrate the future possibilities of applying 3D printers and ABS material in fabricating linear driven motion stages.

Motion of a Cylindrical Object due to Seabed Soil Friction (해저면 토양마찰력에 의한 원통형 물체의 운동)

  • 최경식;강신영;곽한우
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.19-28
    • /
    • 1992
  • The motion of a cylindrical object resting on shallow seabed due to wave forces and soil friction is studied. Given environmental conditions such as wave characteristics and seabed soil properties, the equations of motion are derived and the corresponding reponses of the cylinder in two dimensional plane, i.e., translational and rotational displacements, accelerations, are calculated. The motion is substantially restrained by the penetration of a cylinder into seabed and the parametric study focuses on finding out a minimum penetration depth which makes the cylinder motionless.

  • PDF

CALOS : Camera And Laser for Odometry Sensing (CALOS : 주행계 추정을 위한 카메라와 레이저 융합)

  • Bok, Yun-Su;Hwang, Young-Bae;Kweon, In-So
    • The Journal of Korea Robotics Society
    • /
    • v.1 no.2
    • /
    • pp.180-187
    • /
    • 2006
  • This paper presents a new sensor system, CALOS, for motion estimation and 3D reconstruction. The 2D laser sensor provides accurate depth information of a plane, not the whole 3D structure. On the contrary, the CCD cameras provide the projected image of whole 3D scene, not the depth of the scene. To overcome the limitations, we combine these two types of sensors, the laser sensor and the CCD cameras. We develop a motion estimation scheme appropriate for this sensor system. In the proposed scheme, the motion between two frames is estimated by using three points among the scan data and their corresponding image points, and refined by non-linear optimization. We validate the accuracy of the proposed method by 3D reconstruction using real images. The results show that the proposed system can be a practical solution for motion estimation as well as for 3D reconstruction.

  • PDF

In-Plane and Out-of-Plane Vibration Analysis of Uniformly Curved Pipes Conveying Fluid (내부 유동이 있는 곡선 파이프의 면내 및 면외 진동 해석)

  • Lee, Soo-Il;Chung, Jin-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.649-654
    • /
    • 2000
  • The non-linear differential equations of motion of a fluid conveying curved pipe are derived by making use of Hamiltonian approach. The extensible dynamics of the pipe is based on the Euler-Bernoulli beam theory. Some significant differences between linear and nonlinear equations and the basic analysis results are discussed. Using eigenfrequency analysis, it can be shown that the natural frequencies are changed with flow velocity.

  • PDF

Spacecraft Formation Reconfiguration using Impulsive Control Input

  • Bae, Jonghee;Kim, Youdan
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.2
    • /
    • pp.183-192
    • /
    • 2013
  • This paper presents formation reconfiguration using impulsive control input for spacecraft formation flying. Spacecraft in a formation should change the formation size and/or geometry according to the mission requirements and space environment. To modify the formation radius and geometry with respect to the leader spacecraft, the follower spacecraft generates additional control inputs; the two impulsive control inputs are general control type of the spacecraft system. For the impulsive control input, Lambert's problem is modified to construct the transfer orbit in relative motion, given two position vectors at the initial and final time. Moreover, the numerical simulation results show the transfer trajectories to resize the formation radius in the radial/along-track plane formation and in the along-track/cross-track plane formation. In addition, the maneuver characteristics are described by comparing the differential orbital elements between the reference orbit and transfer orbit in the radial/along-track plane formation and along-track/cross-track plane formation.

3D Target Tracking System using Adaptive Disparity Motion Vector (프레넬 렌즈의 영상 왜곡 보정을 위한 최적의 광학설계)

  • Ko, Jung-Hwan;Lee, Jung-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1205-1206
    • /
    • 2008
  • In the conventional floating display system some image distortions might be occurred in the floating image plane, in which a flat screen has been mostly used for providing an adequate input image plane. In this paper, as a new approach to alleviate image distortion problem in a floating display system, a curved screen is suggested by through some computer simulation using an optics design program of Light Tools.

  • PDF

The Effects of Maintained Muscle Contraction of Abdominal and Pelvic Floor Muscles on 3D Pelvic Stability in Individuals with Chronic Low Back Pain During Gait

  • Yu, Min;Choi, Yu-Ri;Choi, Jeong-Eun;Jeon, Seong-Yeon;Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.3
    • /
    • pp.23-30
    • /
    • 2022
  • PURPOSE: This study was designed to investigate the effects of keeping contraction of abdominal and pelvic floor muscles on 3D pelvic stability in individuals with nonspecific chronic low back pain (CLBP) during normal speed walking. METHODS: The subjects were 20 adults with CLBP deformity and had moderate pain intensity of the visual analog scale. A three-dimensional camera capture system was used to collect kinematic pelvic motion data with and without contraction of the abdominal and pelvic floor muscles during gait. The subjects were asked to walk on a walkway in the lab room and they were attached 40 reflective markers to their pelvic segment and lower extremities. A Visual3D Professional V6 program and Vicon Nexus software were used to analyze 3D pelvic kinematic data. RESULTS: There were significant differences between with and without contraction of the abdominal and pelvic floor muscles of the pelvic depression and the total pelvic motion in coronal plane during gait (p < .05). However, there were no significant differences in any of the maximal motion of the pelvic segment in sagittal and transverse motion plane according to the different muscle contraction conditions (p > .05). CONCLUSION: The results of this study suggest that maintaining co-contraction of the abdominal and pelvic floor muscles in individuals with CLBP increased pelvic stability and contributed to preventing excessive pelvic movements during gait.

Evaluation of Accuracy and Inaccuracy of Depth Sensor based Kinect System for Motion Analysis in Specific Rotational Movement for Balance Rehabilitation Training (균형 재활 훈련을 위한 특정 회전 움직임에서 피검자 동작 분석을 위한 깊이 센서 기반 키넥트 시스템의 정확성 및 부정확성 평가)

  • Kim, ChoongYeon;Jung, HoHyun;Jeon, Seong-Cheol;Jang, Kyung Bae;Chun, Keyoung Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.228-234
    • /
    • 2015
  • The balance ability significantly decreased in the elderly because of deterioration of the neural musculature regulatory mechanisms. Several studies have investigated methods of improving balance ability using real-time systems, but it is limited by the expensive test equipment and specialized resources. Recently, Kinect system based on depth data has been applied to address these limitations. Little information about accuracy/inaccuracy of Kinect system is, however, available, particular in motion analysis for evaluation of effectiveness in rehabilitation training. Therefore, the aim of the current study was to evaluate accuracy/inaccuracy of Kinect system in specific rotational movement for balance rehabilitation training. Six healthy male adults with no musculoskeletal disorder were selected to participate in the experiment. Movements of the participants were induced by controlling the base plane of the balance training equipment in directions of AP (anterior-posterior), ML (medial-lateral), right and left diagonal direction. The dynamic motions of the subjects were measured using two Kinect depth sensor systems and a three-dimensional motion capture system with eight infrared cameras for comparative evaluation. The results of the error rate for hip and knee joint alteration of Kinect system comparison with infrared camera based motion capture system occurred smaller values in the ML direction (Hip joint: 10.9~57.3%, Knee joint: 26.0~74.8%). Therefore, the accuracy of Kinect system for measuring balance rehabilitation traning could improve by using adapted algorithm which is based on hip joint movement in medial-lateral direction.

Joint moments and muscle forces during walking with sided load as one of activities of daily living (편향하중 조건 보행시 인체의 적응 작용에 대한 분석)

  • Kim, Hyun-Dong;Son, Jong-Sang;Kim, Han-Sung;Kim, Young-Ho;Lim, Do-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1709-1712
    • /
    • 2008
  • The trunk is inclined to the loaded side when carrying an object as one of activities of daily living. As the reaction to this behavior the human body may be inclined to his/her trunk to unloaded side. The present study investigated the biomechanical effects of weight variation for sided load carriage during walking upon joint moments and muscle torques, through the tracker agent and joint driving dynamic analysis. To perform the experiment one male was selected as subject for the study. Gait analysis was performed by using a 3D motion analysis system. Thirty nine 14mm reflective markers, according to the plug-in marker set, were attached to the subject. We used BRG.LifeMOD(Biomechanics Research Group, Inc., USA), for skeletal modeling and inverse and joint driving dynamic simulation during one gait cycle. In walking with a sided load carriage, the subject modeled held the carriage with the right hand, which weighed 0, 5, 10, 15kg, 20kg respectively. The result of this simulation showed that knee and hip in the coronal plane were inclined to the loaded side and loaded side had larger moments as the sided load carriage was increased. On the other hand thoracic and lumbar in the coronal plane had larger negative values as the sided loaded carriage was increased. The thoracic and lumbar in the transverse plane also had larger values as the sided load was increased. And the several muscles of loaded side were increased as increasing sided load. It could be concluded that human body is adopted to side loaded circumstances by showing more biologic force. These results could be very useful in analysis for delivery motion of daily life.

  • PDF

A Study on Motion Estimator Design Using Bit Plane (비트 플레인을 이용한 움직임 추정기 설계에 관한 연구)

  • 박종진;이권철;김은원;조원경
    • The Journal of Information Technology
    • /
    • v.3 no.2
    • /
    • pp.39-47
    • /
    • 2000
  • Among the compression methods of moving picture information, a motion estimation method is used to remove time-repeating. The Block Matching Algorithm in motion estimation methods is the commonest one. In recent days, it is required the more advanced high quality in many image processing fields, for example HDTV, etc. Therefore, we have to accomplish not by means of Partial Search Algorithm, but by means of Full Search Algorithm in Block Matching Algorithm. In this paper, it is suggested a structure that reduce total calculation quantity and size, because the structure using Bit Plane select and use only 3bit of 8bit luminance signal.

  • PDF