• Title/Summary/Keyword: Pipe defects

검색결과 172건 처리시간 0.022초

펄스와전류를 이용한 보온재 비해체식 배관감육 평가기술 (Nondestructive evaluation of wall thinning covered with insulation using pulsed eddy current)

  • 박덕근;;이덕현
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.90-95
    • /
    • 2014
  • Local wall thinning is a point of concern in almost all steel structures such as pipe lines covered with a thermal insulator made up of materials with low thermal conductivity(fiberglass or mineral wool); hence, Non Destructive Technique(NDT) methods that are capable of detecting the wall thinning and defects without removing the insulation are necessary. In this study we developed a Pulsed Eddy Current(PEC) system to detect the wall thinning of Ferro magnetic steel pipes covered with fiber glass thermal insulator and shielded with Aluminum plate. The developed system is capable of detecting the wall thickness change through an insulation of thickness 10cm and 0.4mm aluminum shielding. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and coil sensor were used as a detecting element. In both cases, the results show a very good change corresponding to the thickness change of the test specimen. During these experiments a carbon steel tube of diameter 210mm and a length of 620mm, which is covered with insulator of 95mm thickness was used. To simulate the wall thinning, the thickness of the tube is changed for a specified length such as 2.5mm, 5mm and 8 mm from the inner surface of the tube. A 0.4mm thick Aluminum plate was covered on the Test specimen to simulate the shielding of the insulated pipelines. For both hall sensor and coil detection methods Fast Fourier transform(FFT) was calculated using window approach and the results for the test specimen without Aluminum shielding were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra. The PEC system can detect the wall thinning under the 95 mm thickness insulation and 0.4 mm Al shielding, and the output signal showed linear relation with tube wall thickness.

소듐냉각고속로 원형로 중간열전달계통 고온배관의 파단전누설 예비평가 (Preliminary Leak-before Break Assessment of Intermediate Heat Transport System Hot-Leg of a Prototype Generation IV Sodium-cooled Fast Reactor)

  • 이사용;김낙현;구경회;김성균;김윤재
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.126-133
    • /
    • 2016
  • Recently, the research and development of Sodium-cooled Fast Reactors (SFRs) have made progresses. However, liquid sodium, the coolant of an SFR, is chemically unstable and sodium fire can be occurred when liquid sodium leaks from sodium pipe. To reduce the damage by the sodium fire, many fire walls and fire extinguishers are needed for SFRs. LBB concept in SFR might reduce the scale of sodium fire and decrease or eliminate fire walls and fire extinguishers. Therefore, LBB concept can contribute to improve economic efficiency and to strengthen defense-in depth safety. The LBB assessment procedure has been well established, and has been used significantly in light water reactors (LWRs). However, an LBB assessment of an SFR is more complicated because SFRs are operated in elevated temperature regions. In such a region, because creep damage may occur in a material, thereby growing defects, an LBB assessment of an SFR should consider elevated temperature effects. The procedure and method for this purpose are provided in RCC-MRx A16, which is a French code. In this study, LBB assessment was performed for PGSFR IHTS hot-leg pipe according to RCC-MRx A16 and the applicability of the code was discussed.

배관 진단을 위한 배열형 유도초음파 검사시스템 개발 (A Development of an Array Guided Wave Ultrasonic Testing System for pipe inspection)

  • 조현준;이동훈;강토;박진호;한성진
    • 한국가스학회지
    • /
    • 제19권5호
    • /
    • pp.29-35
    • /
    • 2015
  • 국내 에너지, 석유화학 산업분야에서 주로 사용되는 배관은 다양한 요인에 의해 발생하는 결함들에 대한 검출과 평가가 상시적으로 이슈화되곤 한다. 에너지와 석유화학 배관은 특성상 비교적 긴 거리에 걸쳐 시공되는 경우가 많고 다양한 부위에 여러 형태의 결함이 존재하게 되는데, 본 연구를 통해 국내 배관에 주로 발생하는 보온재 아래의 부식을 보다 효율적으로 검출하기 위한 방법으로 유도초음파 검사기법을 활용하는 시스템과 신호개선방법을 개발했다. 배관 내 결함의 검출능을 높일 수 있는 수단으로 초음파 탐촉자를 배열화하여 유도초음파를 발생시키고 신호대잡음비를 개선할 목적으로 송신 집속기법이 가능하도록 했다. 본 논문에서는 배열 유도초음파 검사시스템의 개발과 송신 집속을 통한 신호대잡음비 개선에 관해 기술한다.

적외선열화상을 이용한 원자력발전소 감육 배관의 결함 검출 (Defect Detection of the Wall Thinning Pipe of the Nuclear Power Plant Using Infrared Thermography)

  • 김경석;장호섭;홍동표;박찬주;나성원;김경수;정현철
    • 비파괴검사학회지
    • /
    • 제30권2호
    • /
    • pp.85-90
    • /
    • 2010
  • 절대온도(OK) 이상의 온도를 가지고 물체는 표면온도에 대응하는 적외선 파장대역에서 적외선 에너지를 방출하게 된다. 적외선열화상은 적외선 파장대역에 반응하는 검출기를 이용하여 검출된 적외선 량을 온도로 변환하고 사용자에게 적외선영상을 실시간으로 제공하는 비파괴검사 방법이다 원자력발전소의 배관은 부식, 피로 등으로 인해 두께가 얇아져 큰 사고로 이어질 수 있는 결함이 발생하므로 이를 위한 효율적인 비파괴검사 시스템이 요구되고 있다. 따라서 본 연구에서는 적외선열화상 카메라로 측정한 온도와 배관의 결함 깊이 및 크기와의 상관관계를 알아보고 이를 원자력발전소 배관에 적용하여 결함을 검출하는 연구를 수행하였다.

지역난방 냉각수 배관의 용접부 파손 분석 (Failure Analysis of Welded type 304 in Cooling Water Pipeline of District Heating System)

  • 정준철;김우철;김경민;손홍균;김정구;이수열;김희산
    • Corrosion Science and Technology
    • /
    • 제19권6호
    • /
    • pp.296-301
    • /
    • 2020
  • Failure analysis on the welded type 304 pipe used for cooling water piping in the district heating primary side was conducted. Inorganic elements and bacteria in the cooling water and in corrosion products were analyzed, and the weldment was inspected by microscopy and a sensitization test. Corrosion damages were observed in the heat-affected zone, on weld defects such as incomplete fusion or excessive penetration caused by improper welding, or/and at the 6 o'clock position along the pipe axial direction. However, the level of concentration of chloride in the cooling water as low as 80 ppm has been reported to be not enough for even a sensitized type 304 steel, meaning that the additional corrosive factor was required for these corrosion damages. The factor leading to these corrosion damages was drawn to be the metabolisms of the types of bacteria, which is proved by the detection of proton, sulfur containing species, biofilms, and both bacteria and corrosion product analyses.

원전 배관 루프시스템의 냉각 위상잠금 적외선열화상을 이용한 결함 검출에 관한 연구 (A Study about Detection of Defects in the Nuclear Piping Loop System Using Cooling Lock-in Infrared Thermography)

  • 김상채;강성훈;윤나연;정현철;김경석
    • 비파괴검사학회지
    • /
    • 제35권5호
    • /
    • pp.321-331
    • /
    • 2015
  • 냉각 위상잠금 적외선열화상 기법을 이용하여 원전 배관 루프시스템의 가열결함 검출의 선행연구를 통하여 냉각결함 검출조건의 적용에 관한 연구를 수행하였다. 배관의 결함가공은 감육 길이, 감육 깊이를 변화시켜 결함조건을 가공하여 루프시스템을 제작하였다. 사용된 장비는 적외선열화상 카메라와 냉각장치를 사용하였으며 냉각장치와 대상 루프시스템과의 거리는 2m로 고정시켜 실험을 수행하였다. 실험 결과의 분석을 위하여 냉각온도 분포, 위상데이터를 확보하고, 이를 분석하여 결함 길이를 측정하였다. 냉각결함 검출조건은 적외선열화상 데이터보다 위상잠금 적외선열화상 데이터가 측정 결과의 신뢰도가 높았다.

국내 하수관로 결함빈도 분석을 통한 CCTV 조사 결함항목 코드 제안 (Suggestion of the Domestic CCTV Inspection Sewer Pipe Defect Codeby Sewer Defect Frequency Analysis)

  • 손주영;이재현;김정률;오재일;윤성수
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.623-634
    • /
    • 2016
  • Sewer condition assessment involves the determination of defective points and status of aged sewers by a CCTV inspection according to the standard manual. Therefore, it is important to establish a reliable and effective standard manual for identifying the sewer defect. In this study, analytic reviews of the CCTV inspection manuals of the UK, New Zealand, Canada and South Korea were performed in order to compare the defect codes and the protocols of condition assessment. Through this, we also established the standardized method for defect code and revised the calculation method of assigning the condition grade. Analyses of the types and frequencies of sewer defects that obtained by CCTV inspection of 7000 case results, showed that the joint defect and lateral defect were the most frequent defects that occurred in Korea. Some defect codes are found to be modified because those did not occur at all. This study includes a proposed new sewer defect codes based on sewer characteristics.

마르코프 연쇄 모델을 이용한 하수관로의 구조적 노후도 추정 (Estimation of Structural Deterioration of Sewer using Markov Chain Model)

  • 강병준;유순유;장전리;박규홍
    • 대한토목학회논문집
    • /
    • 제43권4호
    • /
    • pp.421-431
    • /
    • 2023
  • 하수관로 열화모델은 하수관망을 관리하는 의사결정자에게 자산의 미래 상태 예측에 대한 중요한 정보를 제공할 수 있다. 본 연구에서는 CCTV 조사를 통해서 확보한 구조적 상태평가 이력자료를 기반으로 마르코프 연쇄 모델을 이용하여 하수관로의 노후도를 추정하였다. A시의 3개 배수분구에서 1998-1999년과 2010-2011년에 CCTV 조사에 의해 수집된 관경 450 mm와 600 mm의 흄관 자료를 이용하여 분석하였다. EM 배수분구의 450 mm 관로와 600 mm 관로에서 주요 결함 발생이 다른 두 배수분구보다 빠르게 발생하는 것으로 나타났다. 관로 설치 이후 35년이 지난 시점에는 450 mm 관로의 약 29%, 600 mm 관로의 약 38%가 주요 결함이 발생했으며, 100년 후에는 각각 62%와 74%의 관로가 주요 결함으로 관로 기능을 상실하는 수준으로 나타났다. 관로설치 35년 후, SN 배수분구는 450 mm 관로의 약 26%, 600 mm 관로에서 약 35%, HK 배수분구에서는 450 mm 관로의 약 27%, 600 mm 관로에서 약 37%의 주요 결함이 발생한 것으로 예측되었다. 또한 600 mm 관로가 450 mm 관로보다 평균 12년 정도 빨리 기능 저하가 일어나는 것으로 나타났다. 한편, 관로의 주요 결함등급 비율을 40%로 설정하여 관로의 유효사용수명으로 적용할 경우, 450 mm 관로는 SN배수분구에서 60년, EM배수분구에서 42년, HK배수분구 59년이며, 600 mm 관로에서는 각각 43년, 34년 39년으로 나타났다.

깊이 인자를 고려한 매설배관의 사고피해영향 비교 분석에 관한 연구 (A Study for Comparison of Consequence Analysis for Buried Pipeline Considering the Depth Factor)

  • 한승훈;설지우;류병태;태찬호;고재욱
    • 한국가스학회지
    • /
    • 제20권5호
    • /
    • pp.9-16
    • /
    • 2016
  • 매설배관은 내부 또는 외부의 결함으로 인하여 leak나 rupture가 발생 할 수 있으며, 가스가 누출 시 큰 사고가 발생할 수 있기 때문에 정량적 위험성평가를 통한 분석이 필요하다. 하지만 현재 매설배관에 대한 위험성 평가시 매설을 고려하지 않거나, 매설 깊이를 고려하지 않고 무조건 배관압력의 1/10으로 가정하는 OGP기준을 사용하고 있는 실정이다. 이에 본 연구에서는 여러 기관의 매설배관 ETA분석자료를 통하여 발생가능 사고 중 Jet fire의 사고피해영향을 분석하였으며, Jet fire의 복사열 계산에 있어서 배관의 매설깊이 인자를 고려한 매설모델을 수립하였다. 사례연구는 New Jersey의 Edison지역에서 발생한 사고를 이용하여 본 모델과 OGP모델을 비교 분석하였다. 연구결과 화염원으로부터 10m거리를 기준으로 매설모델의 복사열 값이 OGP모델에 비해 실제 사례와 비슷한 값을 얻을 수 있었다.

토양 특성 및 전기방식에 따른 연료 가스용 강관의 부식 차이에 관한 연구 (A Study on the Corrosivity according to Soil Characteristics and Electrolytic Protection for the Materials of Fuel Gas Pipe)

  • 임상식;김지선;류영돈;이진한
    • 한국가스학회지
    • /
    • 제20권6호
    • /
    • pp.16-22
    • /
    • 2016
  • 연료가스용 탄소강관이 지하에 매설되는 경우 부식을 방지하기 위해 피복강관을 사용하고 있으며, 피복강관의 결함, 타공사, 시공시 피복의 손상에 대비하여, 방식전위를 이용하여 환원 분위기를 강제로 조성한다. 일반적으로 연료가스용 탄소강관이 지하에 매설된 경우 두 방법이 병행되어 사용되지만, 토양환경의 변화를 예측 할 수 없는 불확실성과 부식 정도 또는 피복의 손상 등 배관의 결함에 대해 육안으로 직접 관찰하기 어려운 문제가 공존한다. 매설배관의 부식이 발생하는 것을 직접적으로 관찰하기 어렵기 때문에, 이를 직접적으로 관찰하기 위한 방법 중 하나가 부식쿠폰을 이용한 방법이다. 본 연구에서는 3가지 토양(마사토, 진흙, 모래)과 방식전위 사용 여부에 따라 작성된 6가지의 시나리오를 토대로 약 1년간 부식쿠폰의 부식 정도를 파악하였다. 그 결과 방식전위가 흐르는 환경의 부식쿠폰은 부식이 전혀 발생하지 않았으며, 미방식 부식쿠폰은 모두 부식이 발생하였다. 토양에 따라서는 진흙에서 가장 적은 부식속도를 보였으며, 모래와 마사토는 유사한 경향을 갖는 것으로 확인되었다. 진흙의 경우 높은 함수량에 의해 국부부식이 발생하였으며, 모래에서 부식이 발생한 것은 모래에 함유된 화학적 성분에 기인한 것으로 확인되었다.