DOI QR코드

DOI QR Code

Suggestion of the Domestic CCTV Inspection Sewer Pipe Defect Codeby Sewer Defect Frequency Analysis

국내 하수관로 결함빈도 분석을 통한 CCTV 조사 결함항목 코드 제안

  • Son, Jooyoung (School of Civil & Environmental Engineering, Urban Design and Studies, Chung-Ang University) ;
  • Lee, Jaehyun (School of Civil & Environmental Engineering, Urban Design and Studies, Chung-Ang University) ;
  • Kim, Jungryul (School of Civil & Environmental Engineering, Urban Design and Studies, Chung-Ang University) ;
  • Oh, Jeill (School of Civil & Environmental Engineering, Urban Design and Studies, Chung-Ang University) ;
  • Yoon, Sungsoo (Bluefox Systems Inc.)
  • 손주영 (중앙대학교 사회기반시스템공학부) ;
  • 이재현 (중앙대학교 사회기반시스템공학부) ;
  • 김정률 (중앙대학교 사회기반시스템공학부) ;
  • 오재일 (중앙대학교 사회기반시스템공학부) ;
  • 윤성수 ((주)블루폭스시스템즈)
  • Received : 2016.10.12
  • Accepted : 2016.10.30
  • Published : 2016.12.23

Abstract

Sewer condition assessment involves the determination of defective points and status of aged sewers by a CCTV inspection according to the standard manual. Therefore, it is important to establish a reliable and effective standard manual for identifying the sewer defect. In this study, analytic reviews of the CCTV inspection manuals of the UK, New Zealand, Canada and South Korea were performed in order to compare the defect codes and the protocols of condition assessment. Through this, we also established the standardized method for defect code and revised the calculation method of assigning the condition grade. Analyses of the types and frequencies of sewer defects that obtained by CCTV inspection of 7000 case results, showed that the joint defect and lateral defect were the most frequent defects that occurred in Korea. Some defect codes are found to be modified because those did not occur at all. This study includes a proposed new sewer defect codes based on sewer characteristics.

Keywords

References

  1. Chughtai, F., & Zayed, T. (2011). Integrating WRc and CERIU condition assessment models and classification protocols for sewer pipelines. Journal of Infrastructure Systems, 17(3), 129-136. https://doi.org/10.1061/(ASCE)IS.1943-555X.0000052
  2. Dirksen, J., Clemens, F. H. L. R., Korving, H., Cherqui, F., Le Gauffre, P., Ertl, T., & Snaterse, C. T. M. (2013). The consistency of visual sewer inspection data. Structure and infrastructure engineering, 9(3), 214-228. https://doi.org/10.1080/15732479.2010.541265
  3. EPA, (2009), Condition assessment of wastewater collection systems EPA/600/R-09/049
  4. EPA, (2015), Condition assessment of underground pipes - with excerpts from: condition assessment of wastewater collection systems, EPA/600/R-09/049
  5. G. Kley, I. Kropp, T. Schmidt, & N. Caradot. (2013). Review of available technologies and methodologies for sewer condition evaluation, Project acronym: SEMA. Kompetenzzentrum Wasser Berlin
  6. Han, S., Shin, H., & Hwang, H. (2013). Failure risk assessment of reinforced concrete sewer pipes on crack-related defects. Journal of Korean Society of Water and Wastewater, 27(6), 731-741. https://doi.org/10.11001/jksww.2013.27.6.731
  7. Han, S., Shin, H., & Hwang, H. (2013). Failure risk assessment of reinforced concrete sewer pipes on joint-related defects. Journal of Korean Society of Water and Wastewater, 27(6), 787-796. https://doi.org/10.11001/jksww.2013.27.6.787
  8. Khazraeializadeh, S. (2012). A Comparative Analysis on Sewer Structural Condition Grading Systems Using Four Sewer Condition Assessment Protocols. In Masters Abstracts International (Vol. 51, No. 03). ISO 690
  9. Khazraeializadeh, S., Gay, L. F., & Bayat, A. (2014). Comparative analysis of sewer physical condition grading protocols for the City of Edmonton. Canadian Journal of Civil Engineering, 41(9), 811-818. https://doi.org/10.1139/cjce-2014-0077
  10. KWWA(Korea water and wastewater works association). (2015). Sewer construction standard specification
  11. Lee, J. (2015). Sewer O&M importance in the old sewer detail inspection process. Water Journal(in December)
  12. Ministry of Environment. (2010). Sewer CCTV inspection.judgment standardization and maintenance and repair criteria research
  13. Ministry of Environment. (2011). Standard Manual of Sewer CCTV Inspection and Renovation Criteria, ROK.
  14. Ministry of Environment. (2014). Statistics of sewerage, ROK.
  15. Ministry of Environment. (2015). Standard Manual of Sewer detail Inspection for ground subsidence, ROK.
  16. NASSCO. (2013). Infrastructure Condition Assessment and Certification Programs(PACP/MACP/LACP), National Association of Sewer Service Companies, USA, 2012 and 2013 Trainer of the Year
  17. NZWWA. (2006). New Zealand pipe inspection manual, 3rd Ed., NZWWA, Wellington, New Zealand.
  18. Opila, M. C., & Attoh-Okine, N. (2011). Novel approach in pipe condition scoring. Journal of pipeline systems engineering and practice, 2(3), 82-90. https://doi.org/10.1061/(ASCE)PS.1949-1204.0000081
  19. Rahman, S., & Vanier, D. J. (2004). An evaluation of condition assessment protocols for sewer management.
  20. Thornhill, R., and Wildbore, P. (2005). Sewer defect codes: Origin and destination.
  21. WRc. (2001). Manual of Sewer Condition Classification, 4th edn., Water Research Centre, UK
  22. Young, O. C., & O'Reilly, M. P. (1983). A guide to design loadings for buried rigid pipes (No. Monograph). HM Stationery Office.

Cited by

  1. 하수관로 결함 점수 및 상태 등급 판정 방법 제안 vol.31, pp.1, 2017, https://doi.org/10.11001/jksww.2017.31.1.021
  2. 대형 하수박스암거의 속성 데이터베이스 구축을 위한 결함유형 평가 vol.31, pp.6, 2017, https://doi.org/10.11001/jksww.2017.31.6.619