• 제목/요약/키워드: Photovoltaic power plants

검색결과 76건 처리시간 0.019초

태양광발전 시스템을 이용한 전력품질 보상시스템 (Power Quality Compensate System Using Photovoltaic System)

  • 한석우;최규하;장도현;신우석;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.76-80
    • /
    • 2001
  • Voltage harmonics resulting from current harmonies produced by the nonlinear loads have become a serious problems in many systems. Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. In this paper, proposed power quality compensate system using photovoltaic system is not only for harmonic compensation but also for harmonic isolation between supply and load, and for voltage regulation and unbalance compensation. Through computer simulations, we have verified the effectiveness of the proposed system.

  • PDF

GIS를 활용한 수상 태양광 발전소 입지 분석 (Floating Photovoltaic Plant Location Analysis using GIS)

  • 이기림;이원희
    • 대한공간정보학회지
    • /
    • 제24권1호
    • /
    • pp.51-59
    • /
    • 2016
  • 전 세계 화석 에너지의 사용량은 지속적으로 증가하고 있다. 기존의 화석 에너지 사용 국가뿐만 아니라 개발도상국의 화석 에너지 사용량 또한 증대되면서 유한한 화석 에너지의 고갈에 대한 불안감은 커지고 있다. 또한 화석에너지로 인한 환경오염, 경제적 사회적 문제는 해결해야 할 과제로 남아있다. 태양광은 환경을 해치지 않는 청정에너지이지만, 태양광 발전소를 설치하는 과정에서 여러 문제가 발생한다. 이러한 문제점들을 해결하기 위해 수상 태양광 발전소가 대안으로 떠오르고 있다. 하지만 아직까지 수상 태양광 발전소에 대한 입지 분석이 이루어지지 않고 있다. 본 연구에서는 수상 태양광 발전소의 입지 조건을 지형 및 기후 인자를 이용한 계층분석법을 통해 결과를 분석하였다. 그리고 적합분류표에 따라 각각 인자들의 속성정보에 점수를 부여하고, 여기에 가중치를 곱한 뒤 점수를 시각화하여 분석하였다. 그 결과 경상북도 북부지역의 점수 분포가 남부지역보다 높게 나왔다. 특히 안동시의 안동호와 영양군의 저수지가 최적입지로 추출되었다. 낮은 점수가 나온 곳은 강, 하천의 중심부가 아닌 하천의 경계면이었다. 본 연구를 통해 더욱 정확한 수상 태양광 발전소 입지 분석이 될 것이라고 기대한다.

실측데이터 기반 소규모 태양광발전소 연계용 ESS 효율 분석에 관한 연구 (A study on the efficiency of ESS installed in a small solar power plant based on actual data)

  • 윤금란;이태규;김정욱
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.350-357
    • /
    • 2019
  • 본 연구에서는 전체 태양광발전소의 80%를 차지하고 있는 소규모 태양광발전소의 에너지저장장치 연계에 따른 시스템 효율을 분석하였다. 설치용량이 100kW인 태양광발전소의 데이터를 수집하고 각 발전소의 PCS와 배터리의 용량에 따른 ESS 효율의 상관관계를 도출하였으며 결론적으로 배터리의 방전속도에 영향을 미치는 C-Rate의 수치가 높을수록 ESS의 방전효율이 높아지는 것으로 나타난다.

방위각과 초친수코팅에 따른 태양광발전량 시뮬레이션과 하수처리장 에너지자립율 산정 (Estimation of energy self-sufficiency in municipal wastewater treatment plant using photovoltaic power simulated by azimuth and hydrophilic coating)

  • 안영섭;김성태;강지훈;채규정;윤종호
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.133-138
    • /
    • 2011
  • This paper presents energy self-sufficiency simulated in municipal wastewater treatment plants (WWTPs) by adopting solar energy production systems that were simulated by varying azimuth and super-hydrophilic coating on the surface of photovoltaic (PV). Relative to the national average energy consumption in WWTPs, the employment of 100 kW PV system was simulated to achieve 2.75% of energy self-sufficiency. The simulated results suggested that the installation of PVs toward South or Southwest would produce the highest energy self-sufficiency in WWTPs. When super-hydrophilic coating was employed in the conventional PV, 5% of additional solar energy production was achievable as compared to uncoated conventional PV. When 100 kW of PV system was installed in a future test-bed site, Kihyeung Respia WWTP located in Yongin, South Korea, the energy self-sufficiency by solar power was simulated to be 1.77%. The simulated solar power production by azimuth and super-hydrophilic coating will be useful reference for practitioners in designing the solar PV systems in the WWTPs.

임차공간 설치 태양광 발전시스템 경제성 평가에 관한 연구 (A Study on leasing space to install solar power systems Economic Evaluation)

  • 서미자;이재환;서태원;한명희;우제택
    • 한국전자통신학회논문지
    • /
    • 제10권12호
    • /
    • pp.1373-1380
    • /
    • 2015
  • 태양광발전소의 급속한 보급과 다양한 설계, 개발, 시공, 유지보수 관련 기술과 기업이 다양하게 공존하며 2010년 초반부터 구축된 최근의 태양광발전소는 발전단가의 하락에도 불구하고 주요 설비의 단가하락과 기술의 안정화로 발전소의 구축이 지속적으로 추진되고 있다. 최근에는 한정된 지상공간을 대체하는 지붕과 구조물 상단을 임차하여 시공하는 형태의 태양광발전소의 건립이 늘어나고 있다. 공장의 지붕, 창고나 물류센터의 지붕 등의 임차공간 설치 태양광발전소의 현황과 기술을 연구하고, 구축 시뮬레이션을 통하여 경제성을 분석하기 위한 검토와 연구를 진행 하였다.

The Analysis of Active Power Control Requirements in the Selected Grid Codes for Wind Farm

  • Kim, Mi-Young;Song, Yong-Un
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1408-1414
    • /
    • 2015
  • The renewable energies such as photovoltaic power, wind power and biomass have grown to a greater extent as decarbonization techniques. The renewable energies are interconnected to power systems (or electrical grids) in order to increase benefits from economies of scale, and the extra attention is focused on the Grid Code. A grid code defines technical parameters that power plants must meet to ensure functions of power systems, and the grid code determined by considering power system characteristics is various across the country. Some TSO (Transmission System Operator) and ISO (Independent System Operator) have issued grid code for wind power and the special requirements for offshore wind farm. The main purpose of the above grid code is that wind farm in power systems has to act as the existing power plants. Therefore wind farm developer and wind turbine manufacturer have great difficulty in grasping and meeting grid code requirements. This paper presents the basic understanding for grid codes of developed countries in the wind power and trends of those technical requirements. Moreover, in grid code viewpoint, the active power control of wind power is also discussed in details.

INTEGRATED SOCIETAL RISK ASSESSMENT FRAMEWORK FOR NUCLEAR POWER AND RENEWABLE ENERGY SOURCES

  • LEE, SANG HUN;KANG, HYUN GOOK
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.461-471
    • /
    • 2015
  • Recently, the estimation of the social cost of energy sources has been emphasized as various novel energy options become feasible in addition to conventional ones. In particular, the social cost of introducing measures to protect power-distribution systems from power-source instability and the cost of accident-risk response for various power sources must be investigated. To account for these risk factors, an integrated societal risk assessment framework, based on power-uncertainty analysis and accident-consequence analysis, is proposed. In this study, we applied the proposed framework to nuclear power plants, solar photovoltaic systems, and wind-turbine generators. The required capacity of gas-turbine power plants to be used as backup power facilities to compensate for fluctuations in the power output from the main power source was estimated based on the performance indicators of each power source. The average individual health risk per terawatt-hours (TWh) of electricity produced by each power source was quantitatively estimated by assessing accident frequency and the consequences of specific accident scenarios based on the probabilistic risk assessment methodology. This study is expected to provide insight into integrated societal risk analysis, and can be used to estimate the social cost of various power sources.

A Review on Floating Photovoltaic Technology (FPVT)

  • Yousuf, Hasnain;Khokhar, Muhammad Quddamah;Zahid, Muhammad Aleem;Kim, Jaeun;Kim, Youngkuk;Cho, Eun-Chel;Cho, Young Hyun;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • 제8권3호
    • /
    • pp.67-78
    • /
    • 2020
  • A novel energy production system which has fascinated a wide consideration because of its several benefits that are called floating photovoltaic technology (FPVT). The FPVT system that helps to minimize the evaporation of water as well as an increase in energy production. For the research purposes, both electrical and mechanical structure requires studying of these systems for the development of FPVT power plants. From different points of views, numerous researches have been directed on FPVT systems that have evaluated these systems. The present research article give a logical investigation and up to date review that shows the different features and components of FPVT systems as an energy production system is offered. This articles reviewing the FPVT that gets the attention of the scientists who have the investigational stage and involuntary inspection of FPVT systems in addition to influence of implementing these systems on the water surface. Also, a comprehensive comparison has been constructed that shows the cons and pros of various types of solar systems that could be installed in various locations. In this review, it has been found that solar energy on the roof of a dwelling house generally has a power of 5 to 20 kW, while the inhabitants of commercial buildings generally have a power of 100 kW or more. The average power capacity of a floating solar panel is 11% more of the average capacity of a solar panel installed on the ground. Studies show that 40% of the water in open reservoirs is lost through evaporation. By covering only 30% of the water surface, evaporation can be reduced by 49%. The global solar panel market exceeds 100 GW and the capacity of 104 GW will bring the annual growth rate to 6%. In 2018, the world's total photovoltaic capacity reached 512 GW, an increase of 27% compared to the total capacity and about 55% of the renewable resources newly created that come from photovoltaic systems. It has been also predicted by this review that in 2025 the Solar technology including the FPVT system will increase by 7.38% that is 485.4 GW more of today installed power worldwide.

GIS를 이용한 태양광시설 설치를 위한 적정지역 선정에 관한 연구 (A Study for Planning Optimal Location of Solar Photovoltaic Facilities using GIS)

  • 윤성욱;백이;장재경;최덕규;강동현;손진관;박민정;강석원;권진경
    • 생물환경조절학회지
    • /
    • 제28권3호
    • /
    • pp.243-254
    • /
    • 2019
  • 본 연구에서는 전국을 대상으로 태양광에너지와 관련된 기상 및 지형 대리변수를 고려하여 태양광발전 시설에 대한 취약지역을 분석하였으며, GIS를 이용하여 공간분석을 통해 태양광발전 시설의 적정입지에 대한 평가용 지도를 개발하였다. 본 연구에서 최종적으로 개발된 태양광발전 시설에 대한 취약지도에서는 '취약단계 5(매우 취약)' 지역과 '취약단계 1(매우좋음)' 지역은 나타나지 않았다. '취약단계 4(취약)' 지역은 전라남도가 가장 크게 나타났으며, '취약단계3(보통)' 지역은 광주광역시, 전라북도, 충청북도 및 강원도 등 다수의 행정구역에서 높은 것으로 나타났다. '취약단계 2(좋음)' 지역은 대구광역시, 울산광역시 및 인천광역시 등이 높은 것으로 나타났다. 현재 운영되고 있는 태양광발전소 30곳을 비교 검토한 결과, 대부분 취약단계 2 및 3단계 지역에 위치하며, 상대적으로 태양광에너지가 적합한 지역에 위치함을 나타냈다. 하지만 본 연구의 한계점인 태양광발전소의 제한적인 자료량으로 인해 본 연구결과의 정확성을 명확하게 평가하기는 어렵다. 그럼에도 불구하고 본 연구에서는 GIS 공간분석 기법을 이용하여 다양한 기상 및 지형요소들을 고려하여 전국을 대상으로 태양광발전시설에 대한 취약지도 평가를 시도하였으며, 국내 전 지역에 대한 자료를 제시함으로써 태양광발전과 관련된 부분에 기초자료로 활용할 수 있을 것이다.

태양광 발전소와 부동산 자산 운용 수익의 경제성 평가에 대한 연구 (Study on Economic Evaluation of Solar Power Plant and Real Estate Asset Management Revenues)

  • 우제택;서미자;이재환
    • 한국전자통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.633-642
    • /
    • 2018
  • 태양광발전소는 급속한 보급을 거듭하며 민간 중심의 부동산 개발과 함께 건물의 부대시설 및 토지, 산악지역과 염전 부지 등 다양한 형태로 수익화 운영을 지속하고 있다. 최근의 태양광발전소는 발전단가의 하락에도 불구하고 주요 설비의 가격 대중화와 기술의 안정화로 발전소 구축이 다시 활발해지고 있다. 그러나 시공에 대한 비용투자와 발전소 운영 수익의 손익분기를 바탕으로 전통적인 부동산 자산 운용과의 수익성 비교검토는 부족한 실정으로 본 논문에서는 부동산 자산운용의 보편화된 형태로 오피스텔과 상가 투자를 바탕으로 태양광 발전시스템의 경제성을 분석하기 위한 검토와 연구를 진행 하였다.