• 제목/요약/키워드: Photovoltaic performance

검색결과 860건 처리시간 0.029초

중규모 태양광발전시스템 장기 실증운전 평가 (The long-term operating evaluation of the grid connected photovoltaic system)

  • 김의환;안교상;임희천
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.14-19
    • /
    • 2009
  • The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 10 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 41.9 MWh in 2008. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 9.6% in 2008. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 10 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

Enhanced Photovoltaic Performance of Perovskite Solar Cells by Copper Chloride (CuCl2) as an Additive in Single Solvent Perovskite Precursor

  • Kayesh, Md. Emrul;Matsuishi, Kiyoto;Chowdhury, Towhid H.;Kaneko, Ryuji;Noda, Takeshi;Islam, Ashraful
    • Electronic Materials Letters
    • /
    • 제14권6호
    • /
    • pp.712-717
    • /
    • 2018
  • In this letter, we have introduced copper chloride ($CuCl_2$) as an additive in the $CH_3NH_3PbI_3$ precursor solution to improve the surface morphology and crystallinity of $CH_3NH_3PbI_3$ films in a single solvent system. Our optimized perovskite solar cells (PSCs) with 2.5 mol% $CuCl_2$ additive showed best power conversion efficiency (PCE) of 15.22%. The PCE of the PSCs fabricated by $CuCl_2$ (2.5 mol%) additive engineering was 56% higher than the PSC fabricated with pristine $CH_3NH_3PbI_3$.

플럭스가 점착된 솔라 리본 건조 연구 (A Study on the Drying Performance of the Flux Adhered to Photovoltaic Ribbon)

  • 조남철;전용한;한상필;김동춘;이채문;전택종
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.29-34
    • /
    • 2015
  • The photovoltaic ribbon attached the flux reduces the solar module manufacturing process and the pollution. This paper presents an analytical method for solving the continuous flux drying system of photovoltaic ribbon. Also, some experiments of the drying of photovoltaic ribbon are carried out in order to design the drying system. Numerical results indicate the air temperature, the air velocity, the air pressure and the timewise temperature variation of ribbon during drying process. In case of the drier process length is short, 400mm, the photovoltaic ribbon is wet. Thus, another study of drying system is necessary to improve the drying ability. As a result, multi-stage drier system is proposed and shown to be good drying ability.

태양전지모듈 고장 진단 알고리즘을 적용한 모니터링시스템 (The Monitoring System with PV Module-level Fault Diagnosis Algorithm)

  • 고석환;소정훈;황혜미;주영철;송형준;신우균;강기환;최정내;강인철
    • 한국태양에너지학회 논문집
    • /
    • 제38권3호
    • /
    • pp.21-28
    • /
    • 2018
  • The objects of PV (Photovoltaic) monitoring system is to reduce the loss of system and operation and maintenance costs. In case of PV plants with configured of centralized inverter type, only 1 PV module might be caused a large loss in the PV plant. For this reason, the monitoring technology of PV module-level that find out the location of the fault module and reduce the system losses is interested. In this paper, a fault diagnosis algorithm are proposed using thermal and electrical characteristics of PV modules under failure. In addition, the monitoring system applied with proposed algorithm was constructed. The wireless sensor using LoRa chip was designed to be able to connect with IoT device in the future. The characteristics of PV module by shading is not failure but it is treated as a temporary failure. In the monitoring system, it is possible to diagnose whether or not failure of bypass diode inside the junction box. The fault diagnosis algorithm are developed on considering a situation such as communication error of wireless sensor and empirical performance evaluation are currently conducting.

3톤급 연안어선용 태양광 발전장치의 전원공급 성능 (Power supply performance photovoltaic (PV) system for 3-ton class fishing vessel)

  • 정성재;이동길;박성욱;김희진
    • 수산해양기술연구
    • /
    • 제50권4호
    • /
    • pp.487-494
    • /
    • 2014
  • This study describes the result on PV system for evaluating the performance of small fishing boats. Photovoltaic system with 200 watts power generation facilities on the 3-ton fishing boat was carried. Load test was performed on the condition that the work lamps lit during night operations. As a result the performance can be used for more than two hours at 60 watt work lamps. The load test was performed on the condition that fishing vessels are on the cruising condition at sea. The solar power systems have been investigated as a power generation efficiency of about 36.55%. Additional tests show that the power generation efficiency is difficult to expect a maximum of 50% or more. Fuel consumption of fishing boats by installing a solar power system is reduced. Also the PV system is useful for the verification of their availability for fishing vessels as well as the satisfaction of the fishermen. The results for the durability of the photovoltaic device is acceptable, including a solar panel, controller and the performance exhibited no breakage in the harsh marine environment or failure so far. The installed PV system was confirmed that the durability with at least 2 years.

Performance Analysis of Cost Effective Portable Solar Photovoltaic Water Pumping System

  • Parmar, Richa;Banerjee, Chandan;Tripathi, Arun K.
    • Current Photovoltaic Research
    • /
    • 제9권2호
    • /
    • pp.51-58
    • /
    • 2021
  • Solar water pumping system (SWPS) is reliable and beneficial for Indian farmers in irrigation and crop production without accessing utility. The capability of easy installation and deployment, makes it an attractive option in remote areas without grid access. The selection of portable solar based pumps is pertaining to its longer life and economic viability due to lower running cost. The work presented in this manuscript intends to demonstrate performance analysis of portable systems. Consequent investigation reveals PSWS as the emerging option for rural household and marginal farmers. This can be attributed to the fact that, a considerable portion (around 45.7%) of the country's land is farmland and irrigation options are yet to reach farmers who entirely rely on rain water at present for harvesting of the crops. According to census 2010-2011 tube wells are the main source for irrigation amongst all other sources followed by canals. Out of the total 64.57-million-hectare net irrigation area, 48.16% is accounted by small and marginal holdings, 43.77% by semi-medium and medium holdings, and 8.07% by large holdings. As per 2015-16 census data, nearly 100 million farming households would struggle to make ends meet. The work included in this manuscript, presents the performance of different commercial brands and different technologies of DC surface solar water micro pumping systems have been studied (specifically, the centrifugal and reciprocating type pumps have been considered for analysis). The performance of the pumping systems has been analyzed and data is evaluated in terms of quantity of water impelled for specific head. The reciprocating pump has been observed to deliver the best system efficiency.

현장 실험을 통한 Sputter Coating 컬러 BIPV 모듈의 발전성능 평가 (Performance Assessment of Sputter-Coating-Colored BIPV Modules Through Field Test)

  • 이효문;윤종호;김현일;이건환
    • 한국태양에너지학회 논문집
    • /
    • 제40권5호
    • /
    • pp.1-12
    • /
    • 2020
  • To assess the performance and characteristics of colored building-integrated photovoltaic (BIPV) modules, a comparative assessment of empirical performance was conducted on colored BIPV modules (gray, blue, and orange) and general BIPV module. These modules were installed on the south-facing slope (30°) for comparative assessment through a field test. Monitoring data were collected every 10 min from December 20, 2019 to January 21, 2020 and used to performance and characteristics analysis. Performance ratio and module efficiency were utilized during performance indexing for comparative assessment. For general BIPV modules, the operational efficiency was analyzed at 16.63%, whereas for colored BIPV modules, 13.70% (gray), 15.12 % (blue), and 14.49% (orange) were analyzed. It was discovered that the efficiency reduction caused by transmission losses owing to the application of colored cover glasses were 17.74% (gray), 9.05% (blue), and 9.86 % (orange), under field testing conditions. These values turned on an additional 7% reduction in efficiency for gray BIPV modules, compared to the degradation resulting from transmission drop (gray: 10.87%, blue: 8.99%, and orange: 9.02%) calculated using the efficiency of each module in standard test conditions (STC). Performance ratio analysis resulted in the following values: 0.92 for general BIPV modules, and 0.85 (gray), 0.91 (blue), and 0.91 (orange) for colored BIPV modules. As demonstrated by the above results, modules with a colored cover glass may differ in their operational performance depending on their color, unlike general modules. Therefore, in addition to the performance evaluation under STC, additional factors of degradation require consideration through field test.

고주파 절연 모듈형 Photovoltaic PCS (Modular Photovoltaic PCS with High-frequency Isolation)

  • 권정민;권봉환
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.11-18
    • /
    • 2005
  • A modular photovoltaic PCS with high-frequency isolation is proposed. The proposed system consists of a SEPIC converter and a full-bridge inverter Using the power slope versus voltage of the PV array, the MPPT controller is proposed that produces a smooth transition to the maximum power point. The dc current of the PV array is estimated without using a dc current sensor The disturbance of the line voltage is detected using a fast sensing technique. Experimental results obtained on a 500W prototype show high performance such as almost unity power factor, $90\%$ power efficiency, $3.6\%$ THD.

  • PDF

발코니 거치 태양광 발전장치의 구조적 안전성에 관한 연구 (A Study on the Structural Safety of Photovoltaic System Mounted on Balcony Railing)

  • 조정제;정유근
    • KIEAE Journal
    • /
    • 제12권2호
    • /
    • pp.33-38
    • /
    • 2012
  • This study aims to evaluate the structural safety of the balcony photovoltaic systems easily installed or moved on the buildings. Also, the systems are controlled by solar altitudes focused on its mobility rather than high efficiency generation performance thereof. The results of the study are as follows. Two types of typical photovoltaic systems which can be mounted on the balcony are proposed, and, the sizes of the systems are designed to be adjusted within certain ranges of the frames in order to attach the various rail sizes. To evaluate the structural safety of the proposed systems, several simulation evaluations are performed on the safety evaluation standards by the Ministry of Construction-Transportation and KCI 2007. The results are that the proposed plans are reasonable in terms of stress and deflection in the structural aspects at the wind pressures of $1,907(N/m^2)$ of external wall surface under the condition of wind velocity higher than 25(m/s).

이중 나노 계면층을 적용한 고효율 고분자 태양 전지 소자 연구 (Nanoscale Double Interfacial Layers for Improved Photovoltaic Effect of Polymer Solar Cells)

  • 이영인;박병주
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.70-75
    • /
    • 2011
  • We introduced nanoscale interfacial layers between the PV layer and the cathode in poly (3-hexylthiophene):methanofullerene bulk-heterojunction polymer photovoltaic (PV) cells. The nanoscale double interfacial layers were made of ultrathin poly (oxyethylenetridecylether) surfactant and low-work-function alloy-metal of Al:Li layers. It was found that the nanoscale interfacial layers increase the photovoltaic performance, i.e., increasing short-circuit current density and fill factor with improved device stability. For PV cells with the nanoscale double interfacial layers, an increase in power conversion efficiency of $4.18{\pm}0.24%$ was achieved, compared to that of the control devices ($3.89{\pm}0.08%$) without the double interfacial layers.