• 제목/요약/키워드: Photoacoustic technique

검색결과 20건 처리시간 0.026초

Review of Photoacoustic Imaging for Imaging-Guided Spinal Surgery

  • Han, Seung Hee
    • Neurospine
    • /
    • 제15권4호
    • /
    • pp.306-322
    • /
    • 2018
  • This review introduces the current technique of photoacoustic imaging as it is applied in imaging-guided surgery (IGS), which provides the surgeon with image visualization and analysis capabilities during surgery. Numerous imaging techniques have been developed to help surgeons perform complex operations more safely and quickly. Although surgeons typically use these kinds of images to visualize targets hidden by bone and other tissues, it is nonetheless more difficult to perform surgery with static reference images (e.g., computed tomography scans and magnetic resonance images) of internal structures. Photoacoustic imaging could enable real-time visualization of regions of interest during surgery. Several researchers have shown that photoacoustic imaging has potential for the noninvasive diagnosis of various types of tissues, including bone. Previous studies of the surgical application of photoacoustic imaging have focused on cancer surgery, but photoacoustic imaging has also recently attracted interest for spinal surgery, because it could be useful for avoiding pedicle breaches and for choosing an appropriate starting point before drilling or pedicle probe insertion. This review describes the current instruments and clinical applications of photoacoustic imaging. Its primary objective is to provide a comprehensive overview of photoacoustic IGS in spinal surgery.

관절염 진단용 광음향 이미징 시스템 개발을 위한 선행 연구 (A Preliminary Study on Developing a Photoacoustic Imaging System for Inflammatory Arthritis Diagnosis)

  • 윤종인;박지원
    • The Journal of Korean Physical Therapy
    • /
    • 제22권4호
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The goal of this study was to investigate the feasibility for the early diagnosis of inflammatory arthritis by the reconstruction of three-dimensional photoacoustic imaging with a tissue phantom. Methods: Q-switched Nd:YAG laser (l = 532 nm) was applied to a tissue phantom to generate photoacoustic waves, and the acquired photoacoustic signals at different positions around the sample were used to recombine the distribution of the optical absorption and the images were subsequently generated through a reconstruction algorithm. Results: From the acquired photoacoustic signals, the surface andinner core of the phantom was clearly distinguished. Furthermore, the back-projection algorithm was able to reconstruct two-dimensional and three-dimensional photoacoustic images that contained the optical absorption property information of the tissue phantom. Conclusion: The results indicate that the photoacoustic imaging technique has many advantages such as high optical contrast and high acoustic resolution. The acquired images can be used for the early diagnosis of inflammatory arthritis by the structural information obtained from the region of interest.

금속에서의 광음향 신호 분석 (An Analysis of The Photoacoustic Signal in Metals)

  • 이종호;전계석
    • 한국음향학회지
    • /
    • 제13권6호
    • /
    • pp.24-30
    • /
    • 1994
  • 본 논문에서는 금속에서의 광음향신호를 분석하기 위해 CW $CO_{2}$ 레이저를 사용하여 광음향 신호검출 시스템을 구성하였으며 알루미늄, 탄소강 및 활동을 샘플로 선택하고 레이저 변조주파수, 록인앰프의 시정수를 변화시키면서 샘플의 종류 및 두께에 따른 수 nA정도의 광음향 신호를 검출하여 신호처리 기법에 의해 금속에서의 광음향 신호의 특성을 분석하였다. 실험결과 시정수를 조정하여 광음향 신호를 안정화시킬 수 있었고 광음향 신호는 금속고유의 열팽창계수에 대한 열용량에 비례하여 증가하고 샘플두께 및 변조주파수에 대하여 지수함수적으로 감소함을 확인하였다.

  • PDF

In situ Photoacoustic Study of Water Gas Shift Reaction over Magnetite/Chromium Oxide and Copper/Zinc Oxide Catalysts

  • Byun, In-Sik;Choi, Ok-Lim;Choi, Joong-Gill;Lee, Sung-Han
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권11호
    • /
    • pp.1513-1518
    • /
    • 2002
  • Kinetic studies on the water-gas shift reaction catalyzed by magnetite/chromium oxide and copper/zinc oxide were carried out by using an in situ photoacoustic spectroscopic technique. The reactions were performed in a closed-circulation reactor system using a differential photoacoustic cell at total pressure of 40 Torr in the temperature range of 100 to $350^{\circ}C.$ The CO2 photoacoustic signal varying with the concentration of CO2 during the catalytic reaction was recorded as a function of time. The time-resolved photoacoustic spectra obtained for the initial reaction stage provided precise data of CO2 formation rate. The apparent activation energies determined from the initial rates were 74.7 kJ/mol for the magnetite/chromium oxide catalyst and 50.9 kJ/mol for the copper/zinc oxide catalyst. To determine the reaction orders, partial pressures of CO(g) and H2O(g) in the reaction mixture were varied at a constant total pressure of 40 Torr with N2 buffer gas. For the magnetite/chromium oxide catalyst, the reaction orders with respect to CO and H2O were determined to be 0.93 and 0.18, respectively. For the copper/zinc oxide catalyst, the reaction orders with respect to CO and H2O were determined to be 0.79 and 0, respectively.

Inspection of Ceramic Coatings Using Nanoindentation and Frequency Domain Photoacoustic Microscopy

  • Steen, T.L.;Basu, S.N.;Sarin, V.K.;Murray, T.W.
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.390-402
    • /
    • 2006
  • The elastic properties and thickness of mullite environmental barrier coatings grown through chemical vapor deposition (CVD) on silicon carbide substrates were measured using frequency domain photoacoustic microscopy. In this technique, extremely narrow bandwidth surface acoustic waves are generated with an amplitude modulated laser source. A photorefractive crystal based interferometer is used to detect the resulting surface displacement. The complex displacement field is mapped as a function of source-to-receiver distance in order to extract the wavelength of the surface acoustic wave at a given excitation frequency, and the phase velocity is determined. The coatings tested exhibited spatial variations in thickness and mechanical properties. The measured surface wave dispersion curves were used to extract an effective value for the elastic modulus and the coating thickness. Nanoindentation was used to validate the measurements of the effective elastic modulus. The average elastic modulus measured through the coating thickness using nanoindentation is compared to the effective modulus found using the photoacoustic system. Optical microscopy is used to validate the thickness measurements. The results indicate that the photoacoustic microscopy technique can be used to estimate the effective elastic properties in coatings exhibiting spatial inhomogeneities, potentially providing valuable feedback for the optimization of the CVD growth process.

광열/광음 기법에 의한 나노초 폭발적 기화 과정 분석 (Analysis of Nanosecond Explosive Vaporization Process by Photothermal/Photoacoustic Methods)

  • 박희권;;최선락;김동식
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.804-812
    • /
    • 2003
  • This paper introduces optical methods for in-situ measurement of surface temperature and pressure transient in thermal processes having nanosecond time scales. In the temperature measurement, a p -Si thin film whose refractive index is calibrated as a function of temperature is embedded beneath the sample surface and the photothermal reflectance is monitored for estimating the surface temperature. The pressure transients are measured using the photoacoustic optical deflection method. The experimental technique is used to analyze the nanosecond laser induced vaporization process that is central to numerous engineering and bio-medical applications. Based on the experimental results, discussions are made on the experimental technique and the physical mechanisms of laser-driven explosive vaporization phenomena.

엽록체의 전자전달과 광음향 신호에 미치는 Simetryne의 영향 (Effect of Simetryne on Chloroplast-Mediated Electron Transport and Photoacoustic Signal)

  • 김현식
    • Journal of Plant Biology
    • /
    • 제31권3호
    • /
    • pp.205-215
    • /
    • 1988
  • The effects of simetryne on light induced electron transport and phosphorylation in isolated spinach (Spinacia oleracea L.) chloroplasts were investigated in comparison with sencor and DCMU. Simetryne, like sencor and DCMU, completely, inhibited PSII electron transport and phosphoryltion with 10-6 M treatment but did not inhibit PSI electron transport. Interference with the electron transport pathway was evidenced by the greater sensitivity of oxygen evolution and uptake than phosphorylation. The following order of decreasing inhibitory effectiveness was exihibited; DCMU>simetryne>sencor. The photoacoustic technique was also used to monitor the relative photosynthetic activity in the leaves treated with the herbicides (simetryne, sencor or DCMU) in vivo and in vitro. Photoacoustic measurements on intact leaves provide quantitative information on two related aspects of the photosynthetic process, namely, photochemical energy storage and oxygen evolution. The relative photoacoustic signal of leaves treated with the herbicides showed low level in 21 Hz, but high level in 380 Hz and on isolated chloroplasts (both 21 Hz and 380 Hz) in comparison with that of the untreated leaves. These results suggest that some of photochemical energy is converted into the heat owing to the inhibition of electorn transport pathway by the herbicides.

  • PDF

임상적용이 가능한 광음향 암 진단 기술 (Clinically translatable photoacoustic imaging of cancer diagnosis)

  • 김미지;박연성;윤창한
    • 한국음향학회지
    • /
    • 제38권4호
    • /
    • pp.476-484
    • /
    • 2019
  • 광음향 영상 기술은 광학영상 및 초음파영상 기법을 융합한 영상 기술로 높은 공간 해상도 및 대조도의 영상을 실시간으로 제공이 가능하다. 광음향 영상은 전임상 연구에서 많은 연구가 진행되었으며 최근 광음향 영상의 임상적 응용을 위한 연구에 많은 노력을 기울이고 있다. 본 논문은 광음향 영상을 이용한 원발 종양 및 전이 진단 기술 연구 현황에 대해 소개하고 임상적용을 위한 문제점에 대해서 알아보도록 한다.

Kinetic Investigation of CO2 Reforming of CH4 over Ni Catalyst Deposited on Silicon Wafer Using Photoacoustic Spectroscopy

  • Yang, Jin-Hyuck;Kim, Ji-Woong;Cho, Young-Gil;Ju, Hong-Lyoul;Lee, Sung-Han;Choi, Joong-Gill
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1295-1300
    • /
    • 2010
  • The $CO_2-CH_4$ reaction catalyzed by Ni/silicon wafers was kinetically studied by using a photoacoustic technique. The catalytic reaction was performed at various partial pressures of $CO_2$ and $CH_4$ (50 Torr total pressure of $CO_2/CH_4/N_2$) in the temperature range of 500 - $650^{\circ}C$ in a static reactor system. The photoacoustic signal that varied with the $CO_2$ concentration during the catalytic reaction was recorded as a function of time. Under the reaction conditions, the $CO_2$ photoacoustic measurements showed the as-prepared Ni thin film sample to be inactive for the reaction, while the $CO_2/CH_4$ reactions carried out in the presence of the sample pre-treated in $H_2$ at $600^{\circ}C$ were associated with significant time-dependent changes in the $CO_2$ photoacoustic signal. The rate of $CO_2$ disappearance was measured from the $CO_2$ photoacoustic signal data in the early reaction period of 50 - 150 sec to obtain precise kinetic data. The apparent activation energy for $CO_2$ consumption was determined to be 6.9 kcal/mol from the $CO_2$ disappearance rates. The partial reaction orders, determined from the $CO_2$ disappearance rates measured at various $PCO{_2}'S$ and $PCH{_4}'S$ at $600^{\circ}C$, were determined to be 0.33 for $CH_4$ and 0.63 for $CO_2$, respectively. Kinetic data obtained in these measurements were compared with previous works and were discussed to construct a catalytic reaction mechanism for the $CO_2-CH_4$ reaction over Ni/silicon wafer at low pressures.

반도체레이저 단면여기 고체레이저에서의 최적 공진조건에 관한 해석 (Analysis of the oscillation condition optimized at laser-diode end-pumped solid-state laser)

  • 김병태;김태석
    • 한국광학회지
    • /
    • 제8권4호
    • /
    • pp.303-307
    • /
    • 1997
  • 반도체레이저로 여기되는 Nd:S-VAP 레이저에서 에너지 변환상태를 PZT를 검출기로 이용한 광음향 분광법으로 측정하였다. 광음향 분광법이 레이저 공진기 내부에서의 에너지 변환과정을 이해하고 공진기에서 출력거울의 최적화를 비교적 간단하게 실현시킬 수 있는 효과적인 측정방법임을 제시하였다.

  • PDF