• Title/Summary/Keyword: Phase plates

Search Result 281, Processing Time 0.026 seconds

Biomechanical Analysis of Golf Driver Swing Motion According to Gender

  • Bae, Kang Ho;Lee, Joong Sook;Han, Ki Hoon;Shin, Jin Hyung
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • Objective: The purpose of this study is to investigate the differences in biomechanical variables of golf driving motion according to gender. Method: A total of 21 healthy golfers (11 men and 10 women) who have more than 5 years of professional experience and have been registered in the Korea Golf Association was recruited. A 250-Hz 8-camera motion capture system (MX-T20, Vicon, LA, USA) was used to capture the motion trajectories of a total of 42 reflective markers attached to the golfer's body and club. Moreover, two 1,000-Hz AMTI force plates (AMTI OR6-7-400, AMTI, MA, USA) were used to measure the ground reaction force. The mean and standard deviation for each parameter were then calculated for both groups of 21 subjects. SPSS Windows version 23.0 was used for statistical analysis. The independent t-test was used to determine the differences between groups. An alpha level of .05 was utilized in all tests. Results: There were differences in joint angles according to gender during golf driver swing. Men showed a statistically significantly higher peak joint angle and maximum range of angle in sagittal and frontal axis of the pelvis, hip, and knee. Moreover, women's swing of the pelvis and hips was found to have a pattern using the peak joint angle and range of angle in the vertical axis of the pelvis and hip. There were the differences in peak joint moment according to gender during golf driver swing. Men used higher joint moment in the downswing phase than women in the extensor, abductor, and external rotator muscles of the right hip; flexor and adductor muscles of left hip joint; and flexor and extensor muscles of the right knee. Conclusion: This result reveals that male golfers conducted driver swing using stronger force of the lower body and ground reaction force based on strength of hip and thigh than female golfers.

Analysis of the Dual Promoters and the $H_2O$$_2$-responsive Element of the cats Gene Encoding Catalase A in Streptomyces coelicolor

  • Cho, You-Hee;Hahn, Ji-Sook;Roe, Jung-Hye
    • Journal of Microbiology
    • /
    • v.38 no.4
    • /
    • pp.239-244
    • /
    • 2000
  • The cats gene encodes the major catalase in Sreptomyces coelicolor, whose production increases upon H$_2$O$_2$treatment. Besides the previously identified primary promoter (catApl), a minor promoter (catAp2) was newly assigned by S1 nuclease mapping. The catAp2 transcript was observed transiently upon entry into the stationary phase in liquid culture and upon differentiation on solid plates, whereas the level of catApl transcription did not chance significantly during this growth transition. ThecatApl promoter was transcribed by the major vegetative RNA polymerase holoenzyme containing $\sigma$$\^$HrdB/, whereas the catAp2 was transcribed in vitro by the holoenzyme containing $\sigma$$\^$R/ that is activated under oxidative conditions. The cia-element regulating the H$_2$O$_2$-inducibility of catApl was identified within the 23 bp inverted repeat sequence located between -65 and -43 of the catApl promoter. We roamed this sequence HRE (H$_2$O$_2$-responsive Element). The distal half of the inverted repeat was more crucial for H$_2$O$_2$-dependent induction of the catApl transcript than the proximal half. HRE most likely serves as a binding site for the H$_2$O$_2$-responsive repressor CatR.

  • PDF

Effects of Y2O3 and Al2O3 Addition on the Properties of Hot Pressed AlN Ceramics (AlN 세라믹의 hot pressing에 사용되는 Y2O3 및 Al2O3 소결조제의 효과)

  • Kong, Man-Sik;Hong, Hyun-Seon;Lee, Sung-Kyu;Seo, Min-Hye;Jung, Hang-Chul
    • Korean Journal of Materials Research
    • /
    • v.17 no.10
    • /
    • pp.560-566
    • /
    • 2007
  • AlN plates were fabricated by hot pressing at $1700-1900^{\circ}C$ using yttria and alumina (3 and $10\;{\mu}m$ particle size) powders as additives and characterized: density, thermal conductivity, transverse rupture strength, and grain size measurement by SEM and EDS. Density values of $3.31-3.34\;g/cm^3$ are largely attributed to hot pressing of powder mixtures in carbon mold under $N_2$ atmosphere which caused effective degree of oxygen removal from yttrium-aluminate phase expected to form at $1100^{\circ}C$. The grain size of hot pressed AlN was almost homogeneous, with size approximately from 3.2 to $4.0\;{\mu}m$ after hot pressing. $Al_2O_3$ powder of $3\;{\mu}m$ particle size resulted in better transverse rupture strength and finer grain size compared to $10\;{\mu}m$ $Al_2O_3$ powder. The thermal conductivity of AlN ranged between $83-92.7\;W/m{\cdot}K$ and decreased with $Al_2O_3$ addition. Fine grain size is preferred for better mechanical properties and thermal conductivity.

Deformation and Failure Behavior during Thermo-Mechanical Fatigue of a Nickel-Based Single Crystal Superalloy (열기계적 피로에 따른 단결정 니켈기 초내열합금의 변형 및 파괴거동)

  • Kang, Jeong Gu;Hong, Hyun Uk;Choi, Baig Gyu;Kim, In Soo;Kang, Nam Hyun;Jo, Chang Yong
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.2
    • /
    • pp.112-120
    • /
    • 2011
  • The out-of-phase thermo-mechanical fatigue (OP TMF) in a <001> oriented single crystal nickel-based superalloy CMSX-4 has been studied. OP TMF life was less than a half of low cycle fatigue(LCF) life in spite of a small hysteresis loop area of OP TMF compared to that of LCF. The failure was caused by the initiation of a crack at the oxide-layered surface followed by its planar growth along the <100> ${\gamma}$ channel in both LCF and OP TMF. However, deformation twins appeared near the major crack of OP TMF. The multiple groups of parallel twin plates on {111} planes provided a preferential path for crack propagation, which caused a significant decrease in OP TMF life. Additionally, the analysis on the surface crack morphology revealed that the tensile strain at the minimum temperature of OP TMF was found to accelerate the crack propagation.

Design Study of a Brazed Plate Heat Exchanger Condenser Through Two-Phase Flow Analysis (이상유동 해석을 통한 브레이징 판형 응축기 설계 연구)

  • Hwang, Dae-jung;Oh, Cheol;Park, Sang-kyun;Jee, Jae-hoon;Bang, Eun-shin;Lee, Byeong-gil
    • New & Renewable Energy
    • /
    • v.18 no.2
    • /
    • pp.73-81
    • /
    • 2022
  • This study was aimed at designing a condenser, as a component of the organic Rankine cycle system for ships. The condenser was manufactured through press molding to achieve a bent shape to enhance the heat transfer performance, considering the shape of the heat transfer plate used in a brazing plate heat exchanger. The heat transfer plate was made of copper-nickel alloy. The required heat transfer rate for the condenser was 110 kW, and the maximum number of layers was set as 25, considering the characteristics of high-temperature brazing. Computational fluid dynamics techniques were used to perform the thermal fluid analysis, based on the ANSYS CFX (v.18.1) commercial program. The heat transfer rate of the condenser was 4.96 kW for one layer (width and length of 0.224 and 0.7 m, respectively) of the heat transfer exchanger. The fin efficiency pertaining to the heat transfer plate was approximately 20%. The heat flow analysis for one layer of the heat exchanger plate indicated that the condenser with 25 layers of heat transfer plates could achieve a heat transfer rate of 110 kW.

Effect of extraction conditions on the stability and safety of sericin

  • Ji Hae, Lee;Hyun-Bok, Kim;HaeYong, Kweon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.45 no.2
    • /
    • pp.93-98
    • /
    • 2022
  • To assess the feasibility of silk sericin for non-textile application, the storage stability and biological safety of sericin were examined. It was extracted at 37℃, 70℃, 100℃, and 121℃ for 1, 3, and 5 h to elucidate the effect of extraction condition on the stability and safety of silk sericin. The solubility was increased till approximately 26% with extraction temperature of 121℃ for 1 h. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) showed that the molecular weight distribution depended on the extraction conditions. Extracted sericin displayed typical UV absorption bands upon spectrometric analysis. To examine the reproducibility of its obtained conformation, sericin was extracted thrice and its circular dichroism (CD) spectra was measured each time. Most CD spectra showed reproducibility regardless of temperature and time except under 100℃ extraction condition. The diversity of CD spectrum showed gradual reduction and was finally coincident with extraction time from 1 to 5 h. Notably, sericin has a negative peak of approximately 200 nm attributed to random coil conformation, regardless of extraction condition. However, at the 100℃ extraction condition, sericin showed both bands to be negative bands of approximately 200 and 220 nm, respectively. Sericin was centrifuged to determine the stability of storage conditions. The sericin extracted at 100℃ and 121℃ for 1 h was found to form gel rapidly within 1 h, but at 121℃ condition, the gel fraction was approximately 20% within 1 h which retained its phase regardless of storage time. The gel fraction of sericin extracted at 100℃ for 5 h increased with time, however at the 121℃ for 5 h condition, the gel fraction was measured to be less than 10% regardless of increase in storage time. PetriflimTM AC plates test showed that sericin was safe from aerobic bacteria activity by extraction under high temperature.

Center of Pressure and Ground Reaction Force Analysis of Task-oriented Sit-to-stand in Stroke Patients (뇌졸중 환자의 과제지향적 일어서기 시 신체압력중심과 지면반발력 특성 )

  • Yoo-Jung, Lim;Joong-Hwi, Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.4
    • /
    • pp.45-52
    • /
    • 2022
  • PURPOSE: This study examined the center of pressure (COP) and ground reaction force (GRF) characteristics during each task-oriented sit-to-stand in stroke patients. METHODS: Twenty stroke subjects were included in this study. The task consisted of sit-to-stand (SS), sit-to-stand for reaching (SR), and sit-to-stand for walking (SW). The response time, COP, and GRF were measured during each task. The COP and GRF data were obtained using a two-force plate. The force plates were placed on a chair (below the buttock) and floor (below the feet). RESULTS: Significant differences were observed between SS (1.48 ± .48 s) and SR (2.09 ± 0.82 s) and between SS and SW (2.27 ± .72 s) in the preparatory phase time during each sit-to-stand exercise (p = .002) and showed significant differences between SS (13.90 ± 6.44 cm) and SW (34.62 ± 39.38 cm) and between SR (16.14 ± 8.04 cm) and SW in the mediolateral COP range during each sit-to-stand exercise (p = .013). CONCLUSION: These findings suggest that more complex task-oriented sit-to-stand exercise requires a high-level motor programming process than a simple sit-to-stand task. Therefore, a variety of tasks-oriented sit-to-stand exercises will be useful training to achieve better ADL ability for stroke patients.

Detection of Undeclared Betamethasone Derivatives in Cosmetic Products Labeled to Contain Zinc Pyrithione as the Active Ingredient (아연피리치온을 유효성분으로 표기한 화장품류에서 미표기 성분인 베타메타손 유도체의 검출)

  • Lee, Jeong-Pyo;Park, Sung-Hwan;Yang, Seong-Jun;Kim, Sun-Mi;Son, Kyung-Hun;Yun, Mi-Ok;Choi, Sang-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.1
    • /
    • pp.11-17
    • /
    • 2009
  • Betamethasone propionate, an anti-inflammatory glucocorticosteroid, was detected in cosmetics with no indication on the label of this compound as an ingredient. The product was formulated as a topical spray or shampoo and labeled to contain zinc pyrithione as the active ingredient. A thin-layer chromatographic analysis was carried out on silica gel plates to provide a first indication about the presence of a compound with steroid structure and reactivity; then high-performance liquid chromatography (HPLC) separation allowed the identification of the corticosteroid agent and its quantification. To identify the corticosteroid agent from these commercial samples we collected the fractions suspected to have ketol steroids by prep HPLC and identified the compound as betamethasone propionate by NMR and MS spectrometry. Then we synthesized the standard for the betamethasone 17-propionate and 21-propionate and quantitate the corticosteroids from the sample by HPLC with that standards. By this method we identified the corticosteroid compounds from some commercial cosmetics such as zinc pyrithione sprays. The finding of betamethasone propionate in the products was shown by comparison to an authenticated standard of betamethasone propionate by retention time on reverse-phase HPLC. Two of the tested products contained betamethasone propionate at the levels of 0.005 ${\sim}$ 0.02% and the others were free of betamethasone propionate.

Development of Flat Plate Type Small Cooling Device (Flat Plate Type 소형 냉각소자 개발)

  • Moon, Seok-Hwan;Hwang, Gunn;You, In-Kyu;Cho, Kyoung-Ik;Yu, Byoung-Gon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.170-174
    • /
    • 2008
  • Recently, a problem related to the thermal management in portable electronic and telecommunication devices is becoming issued. That is due to the trend of slimness of the devices, so it is not easy to find the optimal thermal management technology for the devices. From now on, a pressed circular type cooling device has been mainly used, however the cooling device with thin thickness is becoming needed by the inner space constraint. In the present study, the silicon and metal flat plate type cooling device with the separated vapor and liquid flow path was designed and fabricated. Through the experimental study, the normal isothermal characteristic by vapor-liquid phase change was confirmed and the cooling device with 70mm of total length showed 6.8W of the heat transfer rate within the range of $4{\sim}5^{\circ}C$/W of thermal resistance. In the meantime, the metal cooling device was developed for commercialization. The device was designed to have all structures of evaporator, vapor flow path, liquid flow path and condenser in one plate. And an envelope of that could be completed by combining the two plates of same structure and size. And the simplicity of fabrication process and reduction of manufacturing cost could be accomplished by using the stamping technology for fabricating large flow paths relatively. In the future, it will be possible to develop the commercialized cooling device by revising the fabrication process and enhancing the thermal performance of that.

  • PDF

Biomechanical Analysisz of Varying Backpack Loads on the Lower Limb Moving during Downhill Walking (내림 경사로 보행시 배낭 무게에 따른 하지 움직임의 운동역학적 분석)

  • Chae, Woen-Sik;Lee, Haeng-Seob;Jung, Jae-Hu;Kim, Dong-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.191-198
    • /
    • 2015
  • Objective : The purpose of this study was to conduct biomechanical analysis of varying backpack loads on the lower limb movements during downhill walking over $-20^{\circ}$ ramp. Method : Thirteen male university students (age: $23.5{\pm}2.1yrs$, height: $175.7{\pm}4.6cm$, weight: $651.9{\pm}55.5N$) who have no musculoskeletal disorder were recruited as the subjects. Each subject walked over $20^{\circ}$ ramp with four different backpack weights (0%, 10%, 20% and 30% of body weight) in random order at a speed of $1.0{\pm}0.1m/s$. Five digital camcorders and two force plates were used to obtain 3-d data and kinetics of the lower extremity. For each trial being analyzed, five critical instants were identified from the video recordings. Ground reaction force, loading rate, decay rate, and resultant joint moment of the ankle and the knee were determined by the inverse dynamics analysis. For each dependent variable, one-way ANOVA with repeated measures was used to determine whether there were significant differences among four different backpack weight conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results : The results of this study showed that the medio-lateral GRFs at RHC in 20% and 30% body weight were significantly greater than the corresponding value in 0% of body weight. A consistent increase in the vertical GRFs as backpack loads increased was observed. The valgus joint movement of the knee at RTO in 30% body weight was significantly greater than the corresponding values in 0% and 10% body weight. The increased valgus moment of 30% body weight observed in this phase was associated with decelerating and stabilizing effects on the knee joint. The results also showed that the extension and valgus joint moments of the knee were systematically affected by the backpack load during downhill walking. Conclusion : Since downhill walking while carrying heavy external loads in a backpack may lead to excessive knee joint moment, damage can occur to the joint structures such as joint capsule and ligaments. Therefore, excessive repetitions of downhill walking should be avoided if the lower extremity is subjected to abnormally high levels of load over an extended period of time.