• 제목/요약/키워드: Phase Angle Error

Search Result 138, Processing Time 0.026 seconds

Evaluation Technique of Burden for Current Transformer using Current Transformer Comparator and Precise Shunt Resistor (전류변성기 비교기와 정밀션트저항을 이용한 전류변성기용 부담의 평가기술)

  • Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo;Jung, Jae-Kap
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.250-256
    • /
    • 2006
  • Both ratio error and phase angle error in current transformer(CT) depend critically on values of CT burden. Thus, precise measurement of CT burden is very important for the evaluation of CT. A method for the measurement of CT burden has been developed by employing the portable shunt precise resistor with negligible AC-DC resistance difference less than $10^{-5}$. The burden value(value and power factor) can be calculated from resistance and reactance obtained by measuring the change of ratio error and phase angle error caused by the change of shunt resistor. The uncertainty for the method is evaluated and found to be abut 2 %.

The Iron loss Estimation of IPMSM According to Current Phase Angle

  • Cho, Gyu-Won;Kim, Dong-Yeong;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1345-1351
    • /
    • 2013
  • Variable iron loss as function of current phase angle of Interior Permanent Magnet Synchronous Motor(IPMSM) was calculated through Curve Fitting Method(CFM). Also, a magnetic flux density distribution of iron core according to current phase angle was analyzed, and an iron loss calculation was performed including harmonic distortion. The experiment was performed by production of non-magnetizing model for the separation of mechanical loss, and the iron loss was calculated by the measurement of input using power analyzer and output power using dynamometer. Some error was generated between experimental results and calculation value, but an iron loss diminution according to current phase angle followed a same pattern. So, errors were generated by measurement, vibration, noise, harmonic distortion loss, etc.

Effect of Phase Error on 3-D Image Reconstruction in the Modified Triangular Interferometer (변형 삼각간섭계에서 위상오차가 3차원 복원영상에 미치는 영향에 관한 연구)

  • Kim, Soo-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.1-6
    • /
    • 2009
  • We derive the phase error of hologram due to imperfection of a wave plate, the azimuth angle error of a wave plate, and the azimuth angle error of a linear polarizer. Also, we analyze the effect of phase error by the modified triangular interferometer in case of 3-D image reconstruction of hologram.

Vibration Mode Shape Changed by Phase Angle in Vibration Testing Using Phase-Shifting ESPI (위상이동 ESPI를 이용한 진동실험에서 위상각에 따른 진동모드 형상의 변화)

  • 정현철;김경석;양승필;장호섭;박찬주;조영학;김종수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.443-446
    • /
    • 2003
  • The vibration mode shape changed by the phase angle that can be controlled by phase-shifting ESPI system is discussed. For the phase-shifting ESPI experiment the stroboscopic illumination by using AOM(Acousto-Optic Modulator) is needed, and the initial phase angle can be adjusted by the program. The vibration mode shape is changed when the initial phase angle is changed. We examined the vibration mode shape change due to the initial phase angle change at each resonance frequency. Through this study, we found that in the vibration testing using phase-shilling ESPI the vibration mode shape is improved in the quality by adjusting exact phase angle and the error of the quantitative vibration analysis can be reduced.

  • PDF

An Advanced Phase Angle Measurement Algorithm And Error Analysis (개선된 위상 측정 알고리즘과 오차 해석)

  • 송영석;김재철;최인규;박종식
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.3
    • /
    • pp.25-32
    • /
    • 2004
  • An advanced algorithm for measurement of phase angle between two sinusoidal signals is proposed in this paper. This algorithm uses discrete sample data of two input signals for calculation of phase angle and amplitude. And the key parameters of the measurement algorithm are described by analytical express, so the calculation of phase angle is simplified. In this paper it is proved that harmonic distortion of the input sinusoidal signals does not affect the measurement value of phase angle by using the proposed algorithm when a whole cycle is sampled. And measurement error by the white Gaussian noise is very small compared by other algorithms.

Analysis of Phase Error Due to the Azimuth Angle of the Wave Plates in the Shearography Using Wollaston Prism (Wollaston prism을 이용한 스펙클패턴 전단간섭법에 있어서 파장판의 방위각에 의한 위상오차 해석)

  • Kim, Soo-Gil;Kim, Ki-Soo;Ko, Myung-Sook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.1-7
    • /
    • 2005
  • We introduced the method to obtain four speckle patterns with relative phase shift of ${\pi}/2$ by the polarizing elements, and calculate the phase at each point of the speckle pattern in shearography using Wollaston prism and polarizing elements. Ant we analyzed the phase error caused by the azimuth angles of wave plates used in the proposed method by Jones matrix.

On-Site Evaluation Technique of Linearity for Ratio Error and Phase Angle Error of Current Transformer Comparison Measurement Equipment (전류변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 현장 평가기술)

  • Jung, Jae-Kap;Kwon, Sung-Won;Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.313-316
    • /
    • 2006
  • A method for evaluation of the linearity of both the ratio error and phase angle error in the current transformer(CT) comparison measurement equipment has been developed by employing the standard resistors with negligible AC-DC resistance difference less than $10^{-5}$. The non-reactive standard resistors for the linearity check of the system are used as the external burden connected with the secondary of CT under test. These burdens consist of nine standard resistors, with the nominal resistance of $0.01{\Omega},\;0.1{\Omega},\;0.2{\Omega},\;0.4{\Omega},\;0.6{\Omega},\;1{\Omega},\;2{\Omega},\;4{\Omega}$, and $10{\Omega}$. For linearity check, the developed method has been applied in the CT comparison measurement equipment belonging to the industry.

Range Error of Monopulse Radar according to the Engagement Angle of Cross-Eye Jammer (크로스아이 재머의 조우각에 따른 모노펄스 레이다의 거리 오차)

  • Lim, Joong-Soo;Chae, Gyoo-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.5
    • /
    • pp.30-35
    • /
    • 2020
  • In this paper, we analyzed the tracking error for the monopulse radar by controlling the phase difference, amplitude ratio and engagement angle of the cross-eye jammer. Cross-eye jamming is an important jamming method for monopulse radars, which causes a displacement in the radar receiving antenna input and misleads the radar's tracking angle. As a result of analyzing the tracking distance error of the radar while changing the engagement angle between the monopulse radar and jammer, the maximum distance error occurs when the engagement angle is 0° and the phase difference is 180°. It was confirmed that the error decreased to 70% or less of the maximum distance error into 45°~135°. In order to increase the efficiency of jammers, it is necessary to study rotary jammers or multi-channel jammers. This study will be very useful for the design of cross-eye jammers for aircraft and ships.

Required Performance Analysis of Wavefront Distortion System against Monopulse Radar (모노펄스 레이더에 대한 전파왜곡 시스템의 요구 성능 분석)

  • Jang, Yeonsoo;Kim, Ghiback;Park, Jintae;Lee, Changhoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.577-580
    • /
    • 2016
  • One of the effective jamming methods to disturb monopulse radars is a wavefront distortion. Most well-known wavefront distortion is the cross eye technique which uses two transmitters. The cross eye can make angle error regardless of monopulse radar structure but high accuracies of phase and amplitude between two transmitters should be needed to make large angle error. Thus, the accuracies of phase and amplitude are essentially required performance parameters for implementation of wavefront distortion systems and the required values of accuracy is dependant on amount of angle error. In this paper, we derive expressions for minimum required values of phase difference and amplitude ratio according to amount of angle error and analyze the results.

A Novel Single Phase Synchronous Reference Frame Phase-Locked Loop with a Constant Zero Orthogonal Component

  • Li, Ming;Wang, Yue;Fang, Xiong;Gao, Yuan;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1334-1344
    • /
    • 2014
  • A novel single phase Phase-Locked Loop (PLL) is proposed in this paper to accurately and rapidly estimate the instantaneous phase angle of a grid. A conjugate rotating vector pair is proposed and defined to synthesize the single phase signal in the stationary reference frame. With this concept, the proposed PLL innovatively sets one phase input of the PARK transformation to a constant zero. By means of a proper cancellation, a zero steady state phase angle estimation error can be achieved, even under magnitude and frequency variations. The proposed PLL structure is presented together with guidelines for parameters adjustment. The performance of the proposed PLL is verified by comprehensive experiments. Satisfactory phase angle estimation can be achieved within one input signal cycle, and the estimation error can be totally eliminated in four input cycles for the most severe conditions.