• Title/Summary/Keyword: Personal power

Search Result 794, Processing Time 0.028 seconds

A Real Time Power Quality Monitoring System Using The Wavelet Transform (웨이블릿 변환을 이용한 실시간 전력품질 감시 시스템의 구현)

  • Lee, Kyo-Sung;Yim, Sang-Wook;Lee, Yong-Jea;Kim, Do-Hun;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1241-1243
    • /
    • 2003
  • The wavelet transform can apply various lengths of windows according to the amount of signal frequencies. So characteristics of nonstationary disturbances were found to be more closely monitored by the wavelet transform. In this paper, the wavelet transform is applied to the algorithm for monitoring various power quality disturbances. And personal computer monitoring system was developed.

  • PDF

Longitudinal and Flexural Vibration Analysis of a Beam Type Structure by Transfer Stiffness Coefficient Method (전달강성계수법에 의한 보형구조물의 종.굽힘진동해석)

  • Moon, D.H.;Choi, M.S.;Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.2 no.1
    • /
    • pp.59-66
    • /
    • 1998
  • The authors have studied vibration analysis algorithm which was suitable to the personal computer. Recently, we presented the transfer stiffness coefficient method(TSCM). This method is based on the concept of the transfer of the nodal dynamic stiffness coefficients which are related to force and displacement vectors at each node. In this paper, we describes the general formulation for the longitudinal and flexural coupled vibration analysis of a beam type structure by the TSCM. And the superiority of the TSCM to the finite element method(FEM) in the computation accuracy, cost and convenience was confirmed by results of the numerical computation and experiment.

  • PDF

Transnational Allegories of Image and Likeness in Louisa May Alcott's "Behind a Mask, or A Woman's Power"

  • Jin, Seongeun
    • American Studies
    • /
    • v.43 no.1
    • /
    • pp.83-97
    • /
    • 2020
  • "Behind a Mask" (1866) marks the new direction of Louisa May Alcott's artistic and personal life. Her European trip solidified her identity as a mature woman, most importantly as a mature American woman, one whose independence from Victorian stereotypes would, from now on, make her fortune and fame. Her sensational stories, especially "Behind a Mask," would tell truths that readers recognized but had rarely seen written. These truths would free them, and the author herself, to explore their talents as individuals. Henceforth, Alcott would embody the successful American artistic entrepreneur as one who shed the European domination of false titles and inherited wealth. These motifs of the transnational connection pervade the story, in the form of images and likenesses. Just as Alcott would soon, in two years, reach astonishing financial success with the publication of Little Women, her meteoric ascent parallels America's rise to power in the world's economy, which came about with almost alarming speed after the conclusion of the American Civil War.

Assessment of dust exposure and personal protective equipment among dental technicians (치과기공사의 분진노출 수준 및 개인보호구 착용 실태 - 대구지역을 중심으로 -)

  • Park, Soo-Chul;Jeon, Man-Joong;SaKong, Joon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.93-102
    • /
    • 2011
  • Purpose: The study aimed to evaluate working environment for dental technician by measuring dust level, ventilation conditions and the use of personal protective equipment and to provide basic information required to improve working environment and develop health education programs for dental technician. Methods: A total of 240 dental technician who are registered with the Daegu Association of Dental technician and working at 34 dental laboratories participated in the study. And the dust level was measured at 21 different spots in 16 dental laboratories out of 34. Results: Of 34 dental laboratories, 31 (91.2%) were equipped with a ventilator, but the remaining 3 (8.8%) did not have a ventilator. By the number of ventilator, 1 to 3 ventilators were found in 22 dental laboratories (71.0%), 4 to 6 ventilators were in 7 laboratories (22.5%) and more than 7 ventilators in 2 laboratories(6.5%). According to the frequence of changing filters in dust collector, 20 dental laboratories (58.9%) changed filters every four weeks, 10 laboratories (29.4%) changed them every six weeks and 4 laboratories (11.7%) changed them every eight weeks. Of total respondents, 114 (61.3%) said they wore a mask all the time while working, 56 (29.6%) said they frequently wore a mask, 19 (10.1%) said they did not wear a mask. As for the type of masks, 159 (84.1%) used a disposable mask, 25 (13.2%) used a cotton mask and 5 (2.7%) used an anti-dust mask. For dust sat on their outfits while working, 102 (54.0%) shook their uniforms inside workplace to keep dust off the uniforms, 64 (33.9%) did not anything until they wash their uniforms and 23 (12.1%) shook their uniforms outside workplace to keep dust off the uniforms. Of total respondents, 182 (96.3%) had a particle in their eyes while carrying out grinding work. Based on the measurement of floating dust at workplace, 3 dental laboratories showed dust concentration exceeding the minimum level of 10 mg/$m^3$ allowed under the permit for environment. Of those, 1 laboratory had the dust concentration that was more than 1.5 times higher than the minimum level. Dust concentration was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Dust comprised of nickel (more than 70%), chrome (9%) and others. The mean chrome concentration was more than twice higher than the minimum permissible level of 0.5 mg/$m^3$. There were two laboratories that showed chrome concentration exceeding the level of 0.4 mg/$m^3$. Like dust concentration, chrome level was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. There were six laboratories that had nickel concentration exceeding the minimum permissible level of 1 mg/$m^3$. Of those, one laboratory had nickel concentration that was more than three times higher than the minimum permissible level. Nickel concentration was also higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Conclusion: It is not likely that heavy metal concentrations found in the study constitute respiratory dust. It is however necessary for health of dental technician to apply the Industrial Safety and Healthy Law to dental laboratories and make recommendations for the use of personal protective equipment, installation of a proper number of ventilators, more frequent change of filters in dust collector and improved ventilation for polishing work. At the same time, dental technician need education on how to use personal protective equipment and how to efficiently remove dust from their uniforms.

Public Key based LR-WPAN Security Algorithm (공개키 방식의 LR-WPAN 보안 알고리즘)

  • Kim, Jin-Cheol;Oh, Young-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.54-67
    • /
    • 2006
  • Low Rate WPAN (Wireless Personal Area Network) designed for low power and low cost wireless communication is an important technology to realize ubiquitous environment. IEEE 802.15.4 and ZigBee Alliance recommend the SKKE (Symmetric-Key Key Establishment) protocol for key establishment and management. The SKKE algorithm has security weakness such as the absence of authentication process or electric signature in key generation and exchange when devices join the role of coordinators. In this paper, we propose new key establishment and security algorithm based on public key encryption to solve low rate WPAN security problems. Also, to improve PLC AMR system's weaknesses in communication reliability and security, we propose a new AMR system model based on IEEE 802.15.4 and we apply our security algorithm to AMR profile for security enhancement.

FGPA Design and SoC Implementation for Wireless PAN Applications (무선 PAN 응용을 위한 FPGA 설계 및 SoC)

  • Kim, Young-Sung;Kim, Sun-Hee;Hong, Dae-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.462-469
    • /
    • 2008
  • In this paper, we design the FPGA (Field-Programmable Gate Array) of the KOINONIA WPAN (Wireless Personal Area Network), and implement the SoC (System on Chip). We use the redundant bits to make a constant-amplitude in a modulator part. Additionally, the SNR (Signal to Noise Ratio) performance of the demodulator is improved by using the redundant bits in decoding steps. The four-million FPGA of the KOINONIA WPAN can be operated at 44MHz frequency. The PER (Packet Error Rate) of the designed FPGA with RF (Radio Frequency) module is below 1% at the -86dB MIPLS (Minimum Input Power Level Sensitivity), and the SNR is about 13dB. The SoC is implemented by using Hynix 0.25um CMOS (Complementary Metal Oxide Semiconductor) process. The size of the SoC is $6.52mm{\times}6.92mm$.

The Optimization of IEEE 802.15.4 PHY/MAC with Hardwired Low-MAC (Hardwired Low-MAC 기능을 이용한 IEEE 802.15.4 PHY/MAC 프로토콜 최적화)

  • Hwang, Tae-Ho;Kim, Dong-Sun;Won, Gwang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1B
    • /
    • pp.95-105
    • /
    • 2010
  • IEEE 802.15.4 is the one of the protocols for radio communication in a personal area network. Since it aims to provide low cost and low power communication for ubiquitous communication, it requires high level of optimization in implementation. Recently, there have been many studies on the performance evaluation of IEEE 802.15.4 MAC protocol. According to the results of the studies, it is tendency that the transceiver is implemented to SoC type. On the implementation, the specific functions of MAC like CSMA-CA and MAC frame handling is designed to hardwired functions. In this paper, we implemented the protocol with hardwired low MAC (HL-MAC) and its state machine for the optimization from the physical layer and MAC layer. it has the characteristics of the small code size and the enhanced power consumption.

A Personal Reformer(PR) for your Fuel cell system (연료전지를 위한 개인용 개질기)

  • Kim Hyeon Yeong
    • 한국전기화학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.103-108
    • /
    • 2004
  • The present paper relates to an apparatus in which all carbonaceous material such as coal, oil, plastics and any substance having carbon atoms as part of its constituents are reformed(gasified) into syngas at temperature above $1,200^{\circ}C$(KR patent No.0391121, and PCT/KR2001/01717 and PCT/KR2004/001020). It comprises a single-stage reforming reactor without catalyst and a syngas burner as shown in Fig.2. syngas is combusted with $O_2$ gas in the syngas bunter to produce $M_2O$ and $CO_2$ gas with exothermic heat. Reaction products are introduced into the reforming reactor, reaction heat from syngas burner elevate the temperature of reactor above $1,200^{\circ}C$, and reaction products reduce carbonaceous material down to CO and $H_2$ gases. Reactants and heat necessary for the reaction are provided through the syngas burner only, Neither $O_2$ gas nor steam are injected into the reforming reactor. Reformer is made of ceramic inner lining and sst outer casing. Multiple syngas burners may be connected to the reforming reactor in order to increase the syngas output, and a portion of the product syngas is recycled into syngas burner. The present reformer as shown in Fig.2 is suitable to gasify carbonaceous wastes without secondary pollutants formed from oxidation. Further, it can be miniaturized to accompany a fuel cell system as shown in Fig.3 The output syngas may be used to drive a fuel cell and a portion of electrical power generated in a fuel cell is used to heat a compact reformer up to $1,200^{\circ}C$ so that gas/liquid fossil fuel can efficiently reformed into syngas. The fuel cell serves as syngas burner in Fig.2. The reformation reaction is sustained through recycling a portion of product syngas into a fuel cell and using a portion of electric power generated to heat the reformer for continuous operation. Such reforming reactor may be miniaturized into a size of PC, then you have a Personal Reformer(PR).

  • PDF

Secure 6LoWPAN Neighbor Discovery Address Registration Protocol (안전한 6LoWPAN Neighbor Discovery 주소 등록 프로토콜)

  • Han, Sang-woo;Park, Chang-seop
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.1
    • /
    • pp.17-28
    • /
    • 2019
  • 6LoWPAN based on IEEE 802.15.4 is a realistic standard platform for various Internet of Things (IoT) applications. To bootstrap the LoWPAN (Low-power Wireless Personal Area Network), each device must perform 6LoWPAN-ND address registration to assign a unique IPv6 address. Without adequate security mechanisms, 6LoWPAN-ND is vulnerable to a variety of security attacks including corrupted node attacks. Several security mechanisms have been proposed as a supplement to the vulnerability, but the vulnerability exists because it relies solely on IEEE 802.15.4 hop-by-hop security. In this paper, we propose and analyze a vulnerability of 6LoWPAN-ND address registration and a new security mechanism suitable for preventing the attack of damaged node. It also shows that the proposed security mechanism is compatible with the Internet Engineering Task Force (IETF) standard and is more efficient than the mechanism proposed in the IETF 6 lo WG.

Validation of a Model for Estimating Individual External Dose Based on Ambient Dose Equivalent and Life Patterns

  • Sato, Rina;Yoshimura, Kazuya;Sanada, Yukihisa;Sato, Tetsuro
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.77-85
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Station (FDNPS) accident, a model was developed to estimate the external exposure doses for residents who were expected to return to their homes after evacuation orders were lifted. However, the model's accuracy and uncertainties in parameters used to estimate external doses have not been evaluated. Materials and Methods: The model estimates effective doses based on the integrated ambient dose equivalent (H*(10)) and life patterns, considering a dose reduction factor to estimate the indoor H*(10) and a conversion factor from H*(10) to the effective dose. Because personal dose equivalent (Hp(10)) has been reported to agree well with the effective dose after the FDNPS accident, this study validates the model's accuracy by comparing the estimated effective doses with Hp(10). The Hp(10) and life pattern data were collected for 36 adult participants who lived or worked near the FDNPS in 2019. Results and Discussion: The estimated effective doses correlated significantly with Hp(10); however, the estimated effective doses were lower than Hp(10) for indoor sites. A comparison with the measured indoor H*(10) showed that the estimated indoor H*(10) was not underestimated. However, the Hp(10) to H*(10) ratio indoors, which corresponds to the practical conversion factor from H*(10) to the effective dose, was significantly larger than the same ratio outdoors, meaning that the conversion factor of 0.6 is not appropriate for indoors due to the changes in irradiation geometry and gamma spectra. This could have led to a lower effective dose than Hp(10). Conclusion: The estimated effective doses correlated significantly with Hp(10), demonstrating the model's applicability for effective dose estimation. However, the lower value of the effective dose indoors could be because the conversion factor did not reflect the actual environment.