• Title/Summary/Keyword: Personal exposure

Search Result 639, Processing Time 0.031 seconds

Assessment of correlation between markers of ambient monitoring and biological monitoring of dimethylformamide for workers in synthetic leather manufacturing factories in Korea (국내 합성피혁제조업 근로자에 대한 디메틸포름아미드의 공기중 농도와 생물학적 노출지표간의 상관성 평가)

  • Hwang, Yang In;Lee, Mi-Young;Chung, Yun Kyung;Kim, Eun A
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.315-325
    • /
    • 2013
  • The possibility of acute hepatotoxicity caused by dimethylformamide (DMF) requires regular monitoring of the workers who are using DMF to prevent the occupational disease. The authors performed ambient and biological monitoring of workers involved in synthetic leather manufacturing processes using DMF to assess the correlation between the markers of ambient and biological monitoring of DMF. The authors monitored 142 workers occupationally exposed to DMF from 19 workshops in the synthetic leather and ink manufacturing industries located in northern region of Gyeonggi-do. The subjects answered questionnaire on work procedure and use of personal protective equipment to be classified by exposure type. DMF in air samples collected using personal air samplers, diffusive and active sampler, was analysed using gas chromatograph-flame ionization detector (GC-FID) with DB-FFAP column (length 30 m, i.d. 0.25 mm, film thickness 0.25 ${\mu}m$). Urinary N-methylformamide (NMF) was analysed using gas chromatograph-mass selective detector (GC-MSD) at selected ion monitoring (SIM) mode with DB-624 column (length 60 m, i.d. 0.25 mm, film thickness 1.40 ${\mu}m$). Geometric mean (GM) and geometric standard deviation (GSD) of the ambient DMF was $6.85{\pm}3.43$ ppm, and GM and GSD of urinary NMF was $42.3{\pm}2.7$ mg/L. The ratio of subjects with DMF level over 10 ppm was 44%, and those with urinary NMF over 15 mg/L was 87%. NMF in urine adjusted by DMF in air was $4.61{\pm}2.57$ mg/L/ppm and $9.50{\pm}2.41$ mg/L/ppm, respectively, with or without respirator. There was seasonal differences of NMF in urine adjusted by DMF in air, $7.63{\pm}2.74$ mg/L/ppm in summer and $4.53{\pm}2.29$ mg/L/ppm in winter. The urinary NMF concentration which corresponds to 10 ppm of ambient DMF was 52.7 mg/L (r=0.650, n=128). Considering the difference of the route of exposure which resulted from the compliance of wearing personal protective equipment, the estimated contribution of respiratory and dermal exposure route for DMF was 48.5% vs. 51.5%.

Preliminary Study on Applicability of Accumulate Personal Neutron Dosimeter for Cosmic-ray Exposure of Aviators (운항승무원의 우주방사선 피폭 평가에 있어 누적형 개인 중성자 선량계의 적용가능성 예비 연구)

  • Kim, Hyeong-Jin;Chang, Byung-Uck;Byun, Jong-In;Song, Myeong Han;Kim, Jung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.44-51
    • /
    • 2013
  • ICRP recommended that cosmic ray exposure to the pilot and cabin crew would be considered as an occupational exposure due to their relatively high exposure. Since 2012 with the Act No. 10908 (Natural radiation management), the guideline of cosmic ray exposure to the pilot was established in Korea. The applicability of the solid-state nuclear track detector for personal dose assessment of pilot and cabin crew was evaluated. Dose linearity and angle dependence of dosimeters to the neutron were evaluated by $^{252}Cf$ neutron emitting source. The track density has a good agreement with the dose ($r^2$=0.99) and highly dependent on the degree of an angular of the dosimeter to the neutron source. In addition, the dosimeters (SSNTD) were exposed to cosmic ray in an aircraft during its cruising for more than two months in collaboration with Airline Pilots Association of Korea. Although the correlation between the track density from aircraft cruising altitude and expected neutron dose is low, however RSNS dosimeter could be used for personal neutron dosimeter. For application of RSNS as a personal dosimeter for pilot and cabin crew, additional studies are required.

Respirable Cool Dust Exposure Concentration at Work Sites of Underground Coal Mines in Taebaek Area (태백지역 석탄광산의 작업부서별 호흡성 분진 폭로농도)

  • Yoon, Young No;Chung, Ho Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.47-55
    • /
    • 1991
  • Exposure level of respirable coal dust of underground coal mines in Taebaek area was evaluated. Personal air samplers with 10-mm nylone cyclones were attached to the coal workers including drillers, coal cutters, their assistants, haulers, and separators. Log-normality of respirable dust exposure concentration were tested by Kolmogorov-Smirnov one-sample test. Differences of means of respirable dust exposure concentration between work sites were tested by one-way ANOVA test and multiple comparison(Scheffe) test. And differences of respirable dust exposure concentration of principal and assistant workers in drilling sites and in coal faces were tested by paired t-test. Relation of respirable dust exposure concentration for the principal workers and their assistants in drilling sites and in coal faces were tested by regression analysis. The results were as follows : 1. All of the respirable dust concentration were log-normally distributed. 2. There were not only significantly different means of exposure concentration between drillers and coal cutters but between coal cutters and haulers. 3. Means of exposure concentration of drillers and drilling assistants were not significantly different. And means of exposure concentration of coal cutters and coal cutting assistants were not different.

  • PDF

Indifference Problems of Personal Information Protection of Social Media Users due to Privacy Paradox (소셜미디어 사용자의 프라이버시 패러독스 현상으로 인한 개인정보 무관심 형태에 대한 연구)

  • Kim, Yeonjong;Park, Sanghyeok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.4
    • /
    • pp.213-225
    • /
    • 2019
  • Privacy paradox is a paradoxical behavior that provides personal information even though you are concerned about privacy. Social media users are also often concerned about their personal information exposure. It is even reluctant to describe personal information in profile. However, some users describe their personal information in detail on their profile, provide it freely when others request it, or post their own personal information. The survey was conducted using Google Docs centered on Facebook users. Structural equation model analysis was used for hypothesis testing. As an independent variable, we use personal information infringement experiences. As a mediator, we use privacy indifference, privacy concern, and the relationship with the act of providing personal information. Social media users have become increasingly aware of the fact that they can not distinguish between the real world and online world by strengthening their image and enhancing their image in the process of strengthening ties, sharing lots of information and enjoying themselves through various relationships. Therefore, despite the high degree of privacy indifference and high degree of privacy concern, the phenomenon of privacy paradox is also present in social media.

A Study on Indoor and Personal Exposures Concentrations to Carbon Monoxide in the Asan Area

  • Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.1-3
    • /
    • 2000
  • Indoor carbon monoxide (CO) concentration and personal CO exposures were measured Asan where CO poisoning from twenty coal usage briquette as a domestic fuel to cook and space heating. Twenty-five were houses selected from the Asan area for the survey conducted in February 1997. Newly developed passive CO samplers were placed in the kitchen and living room for the indoor concentration measurement and were worn by homemakers for personal exposure monitoring. The daily average of indoor CO concentration was 16ppm in the kitchen and 10ppm in the living room. The indoor concentration and personal exposures to CO were different in types of the space heating system. House ventilating methods and socioeconomic conditions were also important factors in determining the indoor and personal CO level in Asan.

  • PDF

Methodology for Quantitative Monitoring of Agricultural Worker Exposure to Pesticides (농작업자에 대한 농약 노출의 정량적 측정 방법)

  • Kim, Eun-Hye;Lee, Hye-Ri;Choi, Hoon;Moon, Joon-Kwan;Hong, Soon-Sung;Jeong, Mi-Hye;Park, Kyung-Hun;Lee, Hyo-Min;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.507-528
    • /
    • 2011
  • Agricultural workers who mix/loads and spray pesticide in fields expose to pesticide through dermal and inhalation routes. In such situation, exposed amount should be measured quantitatively for reasonable risk assessment. Patch, gloves, socks and mask will be good materials for monitoring for dermal exposure while personal air monitor equipped with solid adsorbent and air pump will be a tool for inhalation exposure. For extrapolation of absorbed amount in dermal exposure matrices and of trapped amount in solid sorbent to total deraml or inhalation exposure, Korean standard body surface area and respiration rate were proposed in substitution of EPA data. Important exposure factors such as clothing and skin penetration ratio of dermal and inhalation exposure were suggested based on Spraying time for exposure monitoring must be long enough that the amount of pesticide to get absorbed/trapped in exposure matrices results in reasonable analytical value. In domestic case for the both of speed sprayer and power spray machine, spraying time of 20~40 minutes (0.1~0.2 ha) will be reasonable per single replicate before extrapolating to 4 hours a day with triplicates experiment.

Safety and Health Issues among Korean-American Drycleaners: Findings from Focus Groups

  • Jeong, Ae-Suk
    • International Journal of Contents
    • /
    • v.12 no.3
    • /
    • pp.17-21
    • /
    • 2016
  • The purpose of this study was to obtain qualitative data on Korean-American dry cleaners' concerns about work-related health and safety and their attitudes toward the use of PPE(Personal Protective Equipment). Two focus group discussions were conducted with convenient samples of Korean-American drycleaners in middle-eastern state. A total of 13 individuals participated in two focus groups. Participants had concerns as both owners and workers. As owners, they were concerned mostly about compliance of environmental regulation and economic depression. The participants knew very little about the hazards of chemical exposure and expressed vague concerns about chemical exposure and health. Majority of participants do not use PPE and had no intention of using it in the future because of their limited knowledge about the hazardous nature of chemical exposure. The findings from this study would guide the development of intervention to increase drycleaners knowledge of chemical exposure and use of PPE.

Worker Exposure to Asbestos Fibers in Asbestos Slate Manufacturing and Asbestos Textile Industries (석면슬레이트 제조 및 석면방직사업장 근로자의 석면분진폭로)

  • 박두용;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.14 no.2
    • /
    • pp.13-27
    • /
    • 1988
  • Two asbestos slate manufacturing and seven asbestos textile plants in Korea were surveyed from May 20 to July 2, 1987. The purposes of this study were to evaluate 1) worker exposure to asbestos, 2) compliance to the standards and 3) the efficiency of existing local exhaust systems. Sixty-two personal samples and eighty-three area samples were collected and analyzed using "NIOSH 7400" method. Results of this study were as follows. 1. The asbesots exposure concentrations in asbestos textile plants were 1.3 - 14.3 fibers/cc(geometric mean(GM), 4.4 fibers/cc). 2. Worker exposure level to asbestos fiber in asbestos slate manufacturing industry was 0.21 fibers/cc during wet processing, which is below the Korean Standard of 2 fibers/cc. 3. Most local exhaust systems installed in asbestos textile plants were inadequately designed. 4. Ninety-six percent of the 145 samples exceeded the U.S. Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL) of 0.2 fibers/cc and forty-nine percent of the samples exceeded the Korean Standatd of 2 fibers/cc.

  • PDF

Performance Evaluation of Methodology for Personal Exposure Monitoring of ETS and VOCs in Non-occupational Environments (비작업장 환경에서의 ETS와 VOC에 대한 개인피폭량 측정 방법의 성능평가)

  • Baek Seong-Ok;Hwang Seung-Man;Mun Yeong-Hun;Kim Mi-Hyeon;Kim Seong-Ryeol;Choe Jin-Su
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.399-400
    • /
    • 1999
  • From the scientific point of view, any regulation of the emissions of toxic air pollutants in general, and ETS or VOCs in particular, will inevitably be based on exposure levels and consequential health effects, data of this nature is still lacking for most of ETS and VOCs. In this context, the importance of personal monitoring measurements of ETS and VOCs in relation to risk assessment has been emphasized previously.(omitted)

  • PDF

TLD's Glow Curve and Radiation Exposure Amount Analysis at Environment with/without Magnetic Field Exposure as Time Passing (시간 경과에 따른 자기장 노출 유·무 환경에서 열형광선량계의 글로우 곡선 및 피폭 방사선량 분석)

  • Lee, Jae-Heon;Ko, Seong-Jin;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.419-426
    • /
    • 2016
  • The research is done to analyze the change of personal dosimeter according to the elapsed times(24 hours, 1 week, 2 weeks, 3 weeks, 4 weeks) and magnetic field and find out the effective exposure treatment for radiation workers. At first, research the heat treatment and radiation of grouped TLD and keep them in different environments-exposed separately to observe the consequences of glow curve and the level of radiation exposure. As a result, we could find that 24 hours passing TLD group showed the difference in glow curve and the level of radiation. This can be considered as the change caused by magnetic exposure. Also the average radiation exposure level of TLD group, unexposed to the magnetic field, was 15.41 mSv. And the average radiation exposure level of TLD group, exposed to the magnetic field, was 14.83 mSv which decreased the biggest amount(3.80%) among the other groups. If a radiation worker, who works in PET-MRI room, uses TLD as a personal dosimeter, the level of real radiation exposure caused by exposure to the magnetic field won't change significantly as recorded at a regular record cycle but with not regular record but interim record, the lower exposure dose will be appeared than the real level of radiation.