DOI QR코드

DOI QR Code

Preliminary Study on Applicability of Accumulate Personal Neutron Dosimeter for Cosmic-ray Exposure of Aviators

운항승무원의 우주방사선 피폭 평가에 있어 누적형 개인 중성자 선량계의 적용가능성 예비 연구

  • Received : 2013.02.27
  • Accepted : 2013.03.16
  • Published : 2013.03.30

Abstract

ICRP recommended that cosmic ray exposure to the pilot and cabin crew would be considered as an occupational exposure due to their relatively high exposure. Since 2012 with the Act No. 10908 (Natural radiation management), the guideline of cosmic ray exposure to the pilot was established in Korea. The applicability of the solid-state nuclear track detector for personal dose assessment of pilot and cabin crew was evaluated. Dose linearity and angle dependence of dosimeters to the neutron were evaluated by $^{252}Cf$ neutron emitting source. The track density has a good agreement with the dose ($r^2$=0.99) and highly dependent on the degree of an angular of the dosimeter to the neutron source. In addition, the dosimeters (SSNTD) were exposed to cosmic ray in an aircraft during its cruising for more than two months in collaboration with Airline Pilots Association of Korea. Although the correlation between the track density from aircraft cruising altitude and expected neutron dose is low, however RSNS dosimeter could be used for personal neutron dosimeter. For application of RSNS as a personal dosimeter for pilot and cabin crew, additional studies are required.

상대적으로 높은 항공승무원의 우주방사선 피폭을 고려하여 ICRP는 직무피폭의 일부로 간주하고 방사선 방호 대상으로 권고하였으며 이미 유럽 등 일부 국가에서는 항공 고도에서의 항공승무원에 대한 우주방사선 피폭 관리가 이루어지고 있다. 국내에서도 2012년 7월 26일 생활주변방사선안전관리법의 시행과 더불어 항공승무원에 대한 관리 기준이 마련되었다. 본 연구에서는 항공승무원의 개인 선량 평가에서 휴대가 용이한 누적형 고체비적검출기의 적용가능성을 검토하기 위해 수행되었다. 한국표준과학연구원에서 $^{252}Cf$ 중성자 표준 선원을 이용해 선량계의 중성자 선량에 대한 반응도의 선형성과 중성자 입사각에 따른 각도의존성을 평가하였고 한국민간항공조종사협회의 협조를 얻어 항공 고도에 선량계를 노출시켰다. 응답 특성 평가 결과, 선형성에서는 각각의 감속재에 대해 모두 상관계수($r^2$)가 0.99 이상으로 높았고 큰 각도의존성을 나타내었다. 또한 예측된 운항 승무원의 중성자 선량과 비적 밀도와의 상관성은 각각의 감속재에 대하여 r=0.486 (HDPE), r=0.241 (PA)으로 낮게 평가되었다. 누적형 중성자 선량계는 개인 피폭 선량 평가에 활용 가능성이 있을 것으로 판단되나 항공 고도에서의 중성자 에너지 스펙트럼을 고려하여 추가적인 연구가 필요하며 노출 시간을 증가시켜 비적 밀도와의 상관성을 보다 면밀하게 평가할 필요가 있다.

Keywords

References

  1. UNSCEAR. Sources and Effects of Ionizing Radiation. UNSCEAR 2000 REPORT Vol.1. 2008.
  2. UNSCEAR. Sources and Effects of Ionizing Radiation. UNSCEAR 2008 REPORT Vol.1. 2010.
  3. ICRP. 1990 Recommendations of the International Commission on Radiological Protection. ICRP 60. 1990.
  4. European Commission. Evaluation of implementation of radiation protection measures for aircrew. Radiation Protection 156. 2009.
  5. European Commission. Cosmic Radiation Exposure of Aircrew. Radiation Protection 140. 2004.
  6. 한양대학교. 우주선 선량 계측 체계 수립과 비행고도 우주선 방사선장 특성 분석 및 피폭 선량 평가. KINS/GR-300-3. 2005
  7. 한국천문연구원. 북극항공로 우주방사선 안전기준 및 관리 정책 개발 연구. 2009
  8. 이재진, 남욱원, 박귀종, 표창원. 국제우주정거장에서 우주 방사선을 측정하기 위한 조직등가비례계수기(TEPC) 개발 소개. 대한방사선방어학회 추계학술발표회 논문요약집. 2011: 154-155
  9. Bartlett DT, Hager LG, Irvine D, Bagshaw M. Measurements on concorde of the cosmic radiation field at aviation altitudes. Radiat. Prot. Dosim. 2000;91(4):365-376. https://doi.org/10.1093/oxfordjournals.rpd.a033246
  10. Tanner RJ, Bartlett DT, Hager LG. Operational and dosimetric characteristics of etched-track neutron detectors in routine neutron radiation protection dosimetry. Radiat. Meas. 2005;40:549-559. https://doi.org/10.1016/j.radmeas.2005.01.016
  11. Mitaroff A, Silari M. The CERN-EU high-energy reference field (CERF) facility for dosimetry at commercial flight altitudes and in space. Radiat. Prot. Dosim. 2002;102(1):7-22. https://doi.org/10.1093/oxfordjournals.rpd.a006075
  12. Vukovic B, Radolic V, Miklavcic I, Poje M, Varga M, Planinic J. Cosmic radiation dose in aircraft - a neutron track etch detector. J. Environ. Radioact. 2007;98(3):264-273. https://doi.org/10.1016/j.jenvrad.2007.05.002
  13. Zhou D, O'Sullivan D, Flood E. Radiation field of cosmic rays measured at aviation altitudes by CR-39 detectors. Adv. Space. Res. 2006;37(6):1218-1222. https://doi.org/10.1016/j.asr.2005.08.034
  14. O'Sullivan D, Zhou D, Heinrich W, Roesler S, Donnelly J, Keegan R, Flood E, Tommasino L. Cosmic rays and dosimetry at aviation altitudes. Radiat. Meas. 1999;31: 579-584. https://doi.org/10.1016/S1350-4487(99)00131-6
  15. Hulber E, Selmeczi D. Counting recoil proton tracks on PADC without a pre-etching step. A novel approach for neutron dosimeter application. Radiat. Meas. 2005;40:616-619. https://doi.org/10.1016/j.radmeas.2005.04.021
  16. Csige I. Post-irradiation sensitization of CR-39 track detector in carbon dioxide atmosphere. Radiat. Meas. 1997;28:171-176. https://doi.org/10.1016/S1350-4487(97)00062-0
  17. Tayyeb ZA. Use of CR-39 polymer for radiation dosimetry. JKAU Eng. Sci. 2011;22(1):79-96. https://doi.org/10.4197/Eng.22-1.5
  18. Kim JL, Ha C, Yoon Y, Cross WG, Arneja A. Energy and angular response of CR-39 neutron track detector. Journal of the Korean Nuclear Society 1988;20(2):9.
  19. Morelli B, Vilela E, Fantuzzi E. Dosimetric performance of the fast neutron dosemeter for ENEA personal dosimetry service. Radiat. Prot. Dosim. 1999;85(1-4): \105-108. https://doi.org/10.1093/oxfordjournals.rpd.a032810
  20. Fiechtner A, Wernli C. Individual neutron monitoring with CR-39 detectors at an accelerator centre. Radiat. Prot. Dosim. 1999;85(1-4):35-38. https://doi.org/10.1093/oxfordjournals.rpd.a032869
  21. Harvey JR, French AP, Jackson M, Renouf MC, Weeks AR. An automated neutron dosimetry sstem based on the chemical ech of CR39. Radiat. Prot. Dosim. 1997;70(1-4):149-152. https://doi.org/10.1093/oxfordjournals.rpd.a031931
  22. ICRU. Conversion coefficients for use in radiological protection against external radiation. ICRU Report 57. 1998.

Cited by

  1. 일반인들의 항공여객기 이용 시 우주방사선 피폭선량 비교 분석 vol.41, pp.4, 2013, https://doi.org/10.17946/jrst.2018.41.4.339