• 제목/요약/키워드: Permeable Concrete Pavement

검색결과 46건 처리시간 0.017초

보수성 아스팔트 콘크리트의 특성에 관한 연구 (A Study on Properties of Retentive Asphalt Concrete)

  • 장석수;이승한;정용욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.565-568
    • /
    • 2006
  • This study was retentive material into the porosities of the permeable asphalt concrete, we developed retentive asphalt concrete which can absorb water in rain and decrease the temperature of the pavement through the vaporization of rainwater. The experimental results showed that the maximum stability appeared in the 5.0% types of both AP-5 and SBS PMA. Between these two types, the maximum stability of the asphalt with AP-5 was 480kg, which means it met the stability requirement for walkways but didn't meet the requirement for roadways. On the other hand, the maximum stability of the asphalt concrete with SBS PMA was 676kg, which was 176 kg higher than the requirement for roadways(500kg) and satisfy the requirement of KS. The retentive material was 56.4% in the type of the retentive material with 30% diatomaceous earth, 66.6% in 50% type, 87.5% in 70% type. In the aspect of thermal properties, the retentive asphalt concrete can lower the surface temperature by about 15 degrees lower than the normal asphalt concrete can. This effect could be made by the evaporation cooling effect and the surface albedo. It should be noted that the evaporation cooling effect cools it by about 10 degrees and the surface albedo by about 5 degrees.

  • PDF

슬러지 투입 및 휠트랙킹 시험을 이용한 블록 포장의 기능적 투수평가 (Functional Drainage Evaluation of Block Paving through the Usage of Sludge and Wheel Tracking Test)

  • 이상염;정훈희;문성호;박대근;박경민
    • 한국도로학회논문집
    • /
    • 제13권3호
    • /
    • pp.31-38
    • /
    • 2011
  • 주된 도시들의 불투수성 포장화에 따른 현상으로 토양의 사막화를 일으키고 있으며, 나아가, 도시 온난화 현상을 발생시켜 도시지역의 평균 온도를 올리는 원인이 되고 있다. 이로 인해 우수가 투수성 토양에 흡수되거나 잔류되어야 하는 양이 줄어듦에 따라 자주 도심지내에서 범람이 되는 현상을 보여주고 있다. 결국은 우수시스템이 제대로 작동하지 않고 침식이 발생하고 있다. 투수성 포장시스템과 관련해서는 블록 포장이 여러 군데서 수년 동안 사용되어 왔다. 또한 투수성 블록 포장은 전통적으로 사용된 아스팔트 포장 및 콘크리트 포장에 비해 다양한 형태로 사용될 수 있는 장점과 더불어 타 포장보다 미적으로 낳은 면을 보여 주고 있다. 따라서 도로의 현장 조건을 모사하기 위해 본 연구에서는 실험용 슬러지 및 휠 트래킹 장비를 이용한 블록 포장의 기능적인 투수성 평가를 실시하였다.

투수성 주차장에서의 강우 유출저감 및 저류용량 분석 (Analysis of runoff reduction and storage capacity in permeable pavement parking lot)

  • 정용준;민경석
    • 한국습지학회지
    • /
    • 제19권3호
    • /
    • pp.296-302
    • /
    • 2017
  • 일반적으로 주차장은 아스팔트나 콘크리트 등 불투수층으로 조성되기 때문에 강우시 각종 오염물질이 수계로 배출됨에 따라 비점오염원 배출 부하량을 증가시키는 중요한 요인이 된다. 불투수층으로 인한 물순환장애 및 비점오염원 관리를 효과적으로 제어하고 관리할 수 있는 저영향개발(Low Impact Development)의 적용 및 필요성이 대두되고 있으며, 환경부는 개발사업에 대해 저영향개발 기법의 적용을 의무화하는 방안을 추진 중에 있다. 본 연구에서는 효율적인 빗물 및 비점오염원 관리를 위한 저영향개발 기법의 하나인 투수성 주차장에서 발생하는 강우 유출수의 오염물질 농도, 비점오염부하량, 초기세척현상 및 강우유출지연효과를 불투수성 주차장과 비교 분석하여 향후 투수성 주차장 설계시 기초자료로 활용할 수 있도록 하였다.

소규모 하천 친환경 물흐름을 위한 차수특성 (Waterproof Characteristic for Environmental Water Flows in Small Streams)

  • 박민철;김성구;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 2차
    • /
    • pp.192-199
    • /
    • 2010
  • This research produced internal model tester ($2.0m{\times}2.0m{\times}1.0m$) to evaluate the field application of Paju Unjeong District water recycling system for small streams eco-friendly river bed disparity method for the first time in Korea and conducted comparative analysis of the Paju Unjeong District water recycling system field test results and infiltration rate result of internal tests by each rainfall intensity following surface material. Infiltration rate result of internal tests concrete pavement by rainfall intensity following surface material, asphalt pavement, bentonite mate, stabilized soil construction and mixed soil construction manifested low infiltration rate. On the contrary, compaction soil, grassland and water permeable packaging materials resulted in significant amount of infiltration rate. As for the field permeability test results, they were manifested similar tendency as indoor permeability test results and they satisfied the standard for standard of water permeability of domestic disparity facility (less than $1.0{\times}10-7cm$/sec). As compaction rate increased, unconfined compression strength increased as well while coefficient of water permeability decreased.

  • PDF

實環境を考慮したポーラスコンクリートの耐凍害性の評価(실제 환경을 고려한 다공질 콘크리트의 내동해성(耐凍害性) 평가) (Frost resistance of porous concrete assuming actual environment)

  • 中村拓郞;堀口敬;志村和紀;菅原隆
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.227-233
    • /
    • 2008
  • Porous concrete has large continuous voids of 20-30 % by volume, and this concrete is attractive as environmental material in Japan i.e. permeable road pavement, river bank protection with vegetation and green roof system which influence thermal environment. It is necessary to confirm the frost resistance when constructing porous concrete structure in cold region. However applicable test method and evaluation criterion of porous concrete has not defined yet. Therefore, the object of this study is to investigate the frost resistance of porous concrete and this investigation attempts to address this concern by comparing 4 kinds of specified freezing and thawing tests methods (JIS A1148 procedure A/B and RILEM CIF/CDF test) in consideration of actual environment. RILEM freeze-thaw tests are different from JIS A1148 freeze-thaw tests, which are widely adopted for evaluating the frost resistance of conventional concrete in Japan, in water absorption, cooling rate, length of freezing and thawing period, and number of freezing and thawing cycles. RILEM CIF test measures internal damage and is primarily applicable for pure frost attack. CDF test is appropriate for freeze-thaw and de-icing salt attack. JIS A1148 procedure A/B showed extremely low frost resistance of porous concrete if the large continuous voids were filled with water and the ice expansion in the large continuous voids set in during cooling. Frost resistance of porous concrete was improved by mixing coarse aggregate (G7) which particle size is smaller and fine aggregate in JIS freezing and thawing tests. RILEM CIF/CDF test showed that freeze-thaw and de-icing resistance of porous concrete was seems to be superior in that of conventional concrete.

  • PDF

자외선 촉진 내후성 시험에 의한 EPDM Chip을 사용한 탄성포장의 색차분석 (Examination of Color Difference in Elastic Pavement that uses EPDM Chip using Ultraviolet Ray Accelerated Weathering Test)

  • 홍창우
    • 대한토목학회논문집
    • /
    • 제31권1D호
    • /
    • pp.91-98
    • /
    • 2011
  • 최근에 들어 보도나 산책로, 공원 등에 주로 사용되었던 보도블록 및 투수콘크리트 대신 합성고무칩(EPDM Chip)을 사용한 탄성포장이 보행시 충격흡수와 다양한 칼라와 디자인을 연출할 수 있어 사용이 증가되고 있다. 그러나, 자외선에 노출시 합성고무칩의 탄성력, 내구성 등이 저하되고, 황변현상으로 다양한 색상에 의한 경관포장의 기능이 저하되고 있다. 따라서 본 연구에서는 자외선에 노출 시 탄성포장의 주재료인 합성고무칩과 폴리우레탄수지의 색변화를 분석하기 위해 자외선 촉진 내후성 실험을 수행하였다. 그리고 색차계를 이용하여 색공간의 색 수치좌표를 이용하는 방법으로 색차를 정량적으로 분석하였다. 실험결과 기존에 주로 사용되는 BL 폴리우레탄수지의 색변화가 합성고무칩보다 큰 것으로 나타났다. 그리고 BC 폴리우레탄수지의 총색차 ${\Delta}E$가 촉진재령 14일에서 3.162로 BL 폴리우레탄수지의 20.639에 비해 6배 정도 자외선에 대한 색변화 저항성이 높은 것으로 나타났다. 따라서 합성고무칩을 사용하는 탄성포장에서 폴리머 제조시 이소시아네이트를 HMDI로 사용하여 체인형 분자구조를 갖도록 제조된 BC 폴리우레탄수지를 바인더로 사용하는 것이 자외선에 의한 색변화를 억제하는데 매우 효율적인 방법으로 나타났다.