• 제목/요약/키워드: Periodic function

검색결과 436건 처리시간 0.026초

ON THE COMPUTATION OF THE NON-PERIODIC AUTOCORRELATION FUNCTION OF TWO TERNARY SEQUENCES AND ITS RELATED COMPLEXITY ANALYSIS

  • Koukouvinos, Christos;Simos, Dimitris E.
    • Journal of applied mathematics & informatics
    • /
    • 제29권3_4호
    • /
    • pp.547-562
    • /
    • 2011
  • We establish a new formalism of the non-periodic autocorrelation function (NPAF) of two sequences, which is suitable for the computation of the NPAF of any two sequences. It is shown, that this encoding of NPAF is efficient for sequences of small weight. In particular, the check for two sequences of length n having weight w to have zero NPAF can be decided in $O(n+w^2{\log}w)$. For n > w^2{\log}w$, the complexity is O(n) thus we cannot expect asymptotically faster algorithms.

릴레이 제어기구 조기해법에 관한 연구 (A Study of Periodic Solutions of Typical Relay Servo System)

  • 나계근
    • 대한전자공학회논문지
    • /
    • 제8권3호
    • /
    • pp.1-14
    • /
    • 1971
  • 본논문은 릴레이 제어기구의 안정도해석과 종합성능판별의 기초가 되는 리미트사이클진동의 주기해를 정확하고도 신속하게 얻을 수 있는 방법을 개발한 것으로서 특히 궤적법은 동종의 릴레이에 대해서는 특서정수의 변화에 대해서 직각대응시킬 수 있고, 주기해를 정확하게, 그리고 신속하게 직속할 수 있는 장점을 지닌다. 이제까지 다루워 왔던 describing 함수해석법과도 비교하여 그의 부정확성과 불편성 동종릴레이 특성정수변화에 대한 비적응성도 검토하여 궤적법의 우월을 명시하였다.

  • PDF

주기적인 선물체에 대한 Contrast Transfer Function의 수치계산 (Numerical calculation of contrast transfer function for periodic line-space patterns)

  • 김형수;전영세;이종웅;김성호
    • 한국광학회지
    • /
    • 제9권6호
    • /
    • pp.396-402
    • /
    • 1998
  • 광학계의 결상성능평가는 optical transfer function(OTF)을 측정하는 것이 표준적인 방법으로 사용되고 있다. 그러나, 대량 생산되는 광학계의 경우에서는 측정의 편리함 때문에 test pattern을 투영하여 contrast를 검사하는 방법도 많이 사용되고 있다. 본 연구에서는 회절결상이론을 사용하여 주기적 line-space pattern에 대한 contrast transfer function(CTF)을 계산하는 프로그램을 개발하고, C­계수와 Zernike 다항식으로 표현되는 3차 파면수차에 의한 광학계의 modulation transfer function (MTF)과 CTF 변화를 비교, 분석하였다.

  • PDF

신뢰성과 유지보수를 위한 원자로보호계통 주기시험 방법 개발 (RPS Periodic Testing Method for Reliability and Availability)

  • 박주현;이동영;이성진;송덕용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.84-86
    • /
    • 2005
  • The digital systems such as PLC or DCS have been applied to non-safety systems of nuclear power plants because of many difficulties in using analog systems. Nowadays, digital systems have been applied to safety systems of the plants such as reactor protection system. One of the main advantages of digital systems is applicability of automatic testing methods to the systems. The protection system requires high-reliability and high-availability because it shall minimize the propagation of abnormal or accident conditions of nuclear power plants. The calculation of reliability and availability of systems depends on the maintenance period of the system. In general, the maintenance period of the protection system is one-month in case of the manual test. However, the cycle of test can be shortened in several hours by using automatic periodic testing. The reliability and availability of the system is better when test period is shortened because the reliability and availability is inverse proportion to the test period. In this research, we developed the automatic periodic testing method for KNICS Reactor Protection System, which can test the system automatically without an operator or a tester. The automatic testing contained all functions of reaction protection systems from analog-to-digital conversion function of the bistable Processor to the coincident trip function of the coincident processor. By applying the automatic periodic testing to reaction system, the maintenance cost can be cut down and the reliability can be increased.

  • PDF

FFT를 이용한 Hertzian Contact 해석 (Analysis of Hertzian Contact using East Fourier Transform)

  • 구영필;조용주
    • Tribology and Lubricants
    • /
    • 제14권4호
    • /
    • pp.121-127
    • /
    • 1998
  • In this study, a numerical procedure to solve a contact problem has been developed. The procedure takes advantage of signal processing technique in frequency domain to achieve shorter computing time. Boussinesq's equation was adopted as the response function. This procedure is applicable to a non-periodic surface profile as well as a periodic one. The validity of this procedure has been established by comparing the numerical results with the exact solutions. The fastness of this procedure was shown in comparison with other algorithm.

Uniqueness of square convergent triconometric series

  • Ha, Young-Hwa;Lee, Jin
    • 대한수학회지
    • /
    • 제32권4호
    • /
    • pp.785-802
    • /
    • 1995
  • It is well known that every periodic function $f \in L^p([0,2\pi]), p > 1$, can be represented by a convergent trigonometric series called the Fourier series of f. Uniqueness of the representing series is very important, and we know that the Fourier series of a periodic function $f \in L^p([0,2\pi])$ is unique.

  • PDF

레일리 인테그랄의 수치해석상 오차에 대한 이론적 고찰 (Error Analysis Caused by Using the Dftin Numerical Evaluation of Rayleigh's Integral)

  • Kim, Sun-I.
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.323-330
    • /
    • 1989
  • Large bias errors which occur during a numerical evaluation of the Rayleigh's integral is not due to the replicated source problem but due to the coincidence of singularities of the Green's function and the sampling points in Fourier domain. We found that there is no replicated source problem in evaluating the Rayleigh's integral numerically by the reason of the periodic assumption of the input sequence in Dn or by the periodic sampling of the Green's function in the Fourier domain. The wrap around error is not due to an overlap of the individual adjacent sources but berallse of the undersampling of the Green's function in the frequency domain. The replicated and overlApped one is inverse Fourier transformed Green's function rather than the source function.

  • PDF

DYNAMICAL BIFURCATION OF THE ONE DIMENSIONAL MODIFIED SWIFT-HOHENBERG EQUATION

  • CHOI, YUNCHERL
    • 대한수학회보
    • /
    • 제52권4호
    • /
    • pp.1241-1252
    • /
    • 2015
  • In this paper, we study the dynamical bifurcation of the modified Swift-Hohenberg equation on a periodic interval as the system control parameter crosses through a critical number. This critical number depends on the period. We show that there happens the pitchfork bifurcation under the spatially even periodic condition. We also prove that in the general periodic condition the equation bifurcates to an attractor which is homeomorphic to a circle and consists of steady states solutions.

Optimal Preventive Maintenance Policy for a Repairable System

  • Jung, Ki-Mun
    • Journal of the Korean Data and Information Science Society
    • /
    • 제17권2호
    • /
    • pp.367-377
    • /
    • 2006
  • This paper develops a periodic preventive maintenance(PM) policy following the expiration of warranty. Two types of warranty are considered: renewing warranty and non-renewing warranty. Also, we consider the situation where each PM cost is an increasing function of the PM effect. We determine the optimal number of PM's before replacing the system by a new one and the optimal length of period for the periodic PM following the expiration of warranty. Explicit solutions to determine the optimal periodic PM are presented for the Weibull distribution case.

  • PDF

Optimal step stress accelerated life tests for the exponential distribution under periodic inspection and type I censoring

  • Moon, Gyoung-Ae;Park, Yong-Kil
    • Journal of the Korean Data and Information Science Society
    • /
    • 제20권6호
    • /
    • pp.1169-1175
    • /
    • 2009
  • In this paper, the inferences of data obtained from periodic inspection and type I censoring for the step-stress accelerated life test are studied. The exponential distribution with a failure rate function that a log-linear function of stress and the tampered failure rate model are considered. The maximum likelihood estimators of the model parameters are estimated and also the optimal stress change time which minimize the asymptotic variance of maximum likelihood estimators of parameters is determined. A numerical example will be given to illustrate the proposed inferential procedures and the sensitivity of the asymptotic variance of the estimated mean by the guessed parameters is investigated.

  • PDF