• 제목/요약/키워드: Peak load demand

검색결과 188건 처리시간 0.028초

$MgO/H_2O$ 계 화학식 열펌프의 열적 특성에 관한 연구 (A Study on the Thermal Characteristics of a $MgO/H_2O$ Chemical Heat Pump)

  • 권오경;윤재호;김정욱;이진호
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.34-41
    • /
    • 2004
  • The chemical heat pump based on the Dehydration/Hydration process with a MgO/$H_2O$ system has been researched. The reactor bed could be expected to store the heat around 200∼37$0^{\circ}C$ by the dehydration reaction and to release the heat around 100∼16$0^{\circ}C$ by the hydration reaction under the heat amplification mode operation. The heat output rate of the heat pump system was evaluated using the experimentally determined parameters. The results show that 6∼50 W/kg of heat output and 0.5∼0.8 of heat recovery ratio are attainable. The heat pump will be applicable for a load leveling in a co-generation system by chemical storage of surplus heat at low heat demand and by supplying heat in the peak load period.

객체지향기법을 적용한 동적경계부하배분 (DYNAMIC ECONOMIC DISPATCH USING OBJECT-ORIENTED PROGRAMMING)

  • 백영식;권규진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.790-792
    • /
    • 1996
  • According to increase in electric power demand, the increasing rate of peak load compared with that of base load grows larger every year. Thus this paper deals with the optimal dynamic dispatch problem due to power rate limits and spinning reserve with loss or without loss. The first is adjusting module for gradual change of generator power by Object-Oriented Programming. The latter is an efficient dispatch module for the consideration of reasonable spinning reserve requirements. The proposed algorithm has been shown efficiency in real power system with loss.

  • PDF

회귀분석이론을 이용한 지하철 역사의 조명부하밀도 분석 (Recommended Practice for Lighting Load Density by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Subway Stations)

  • 정현기;김세동
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.254-259
    • /
    • 2006
  • It is increased electrical energy consumption with the development of intelligence society in the subway station and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design load density in subway stations, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 34 subway stations and 10 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, maximum and thus it was carried linear and nonlinear regression analysis.

  • PDF

Comparative study on response of thiocyanate shock load on continuous and fed batch anaerobic-anoxic-aerobic sequential moving bed reactors

  • Sahariah, B.P.;Chakraborty, S.
    • Environmental Engineering Research
    • /
    • 제20권1호
    • /
    • pp.65-72
    • /
    • 2015
  • A comparative study on response of a toxic compound thiocyanate ($SCN^-$) was carried out in continuous and fed batch moving bed reactor systems. Both systems had three sequential anaerobic, anoxic and aerobic reactors and operated at same hydraulic retention time. Feed $SCN^-$ was first increased from 600 mg/L to 1,000 mg/L for 3 days (shock 1) and then from 600 to 1,200 mg/L for 3 days (shock 2). In anaerobic continuous reactor, increase of effluent COD (chemical oxygen demand) due to shock load was only 2%, whereas in fed batch reactor it was 14%. In anoxic fed batch reactor recovery was partial in terms of $SCN^-$, phenol, COD and $NO{_3}{^-}$-N and $NO{_2}{^-}$-N removals and in continuous reactor complete recovery was possible. In both systems, inhibition was more significant on aerobic reactors than anaerobic and anoxic reactors. In aerobic reactors ammonia removal efficiency deteriorated and damage was irreversible. Present study showed that fed batch reactors showed higher substrate removal efficiency than continuous reactors during regular operation, but are more susceptible to toxic feed shock load and in nitrifying reactor damage was irreversible.

도시철도 부하특성을 고려한 ESS의 최적 운영방안 연구 (Study on the Optimal Operation of ESS Considering Urban Railway Load Characteristic)

  • 허재행;신승권;박종영;김형익
    • 전기학회논문지
    • /
    • 제64권10호
    • /
    • pp.1508-1516
    • /
    • 2015
  • This paper proposes the optimal operation of ESS (Energy Storage System) in the substation of urban railway in an economical point of view. Since the load patterns of urban railway have different characteristics with the general power demand pattern, the characteristics motivate us to develop the optimal operation algorithm for ESS under Korean electricity billing system. We also introduce two different ESS operation strategies for peak load shaving and electricity consumption charge minimization respectively, and formulate each scheme. Historical data from Namgwangju substation are used for economical comparison of the strategies. The results show that the proposed algorithm is the most cost-effective ESS operation scheme among the strategies and reduces around 5 percent of electric charges compared to the charge without ESS operation.

신재생 에너지가 도입된 전력저장장치의 첨두부하절감 효과를 고려한 최적 구성 알고리즘 (Optimal Configuration Algorithm for ESS with Renewable Energy Resources Considering Peak-shaving Effects)

  • 이나은;김욱원;김진오
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1199-1205
    • /
    • 2014
  • A power system configuration has been increasingly advanced with a number of generating units. In particular, renewable energy resources are widely introduced due to the environmental issues. When applying the renewable energy sources with the ESS (Energy Storage System), the ESS is the role of a potential generating resource in the power system while mitigating the output volatility of renewable energy resources. Thus, for applications of the ESS, the surrounding environment of it should be considered, which means that capacity and energy of the ESS can be affected. Moreover, operation strategy of the ESS should be proposed according to the installation purpose as well as the surrounding environment. In the paper, operation strategy of the ESS is proposed considering load demand and the output of renewable energy resources on a hourly basis. Then, the cost of electrical energy is minimized based on the economic model that consists of capital cost, operation cost, fuel cost, and grid cost for a year. It is sure that peak-shaving effects can be achieved while satisfying the minimum cost of electrical energy.

양방향성 PWM컨버터를 이용한 가정용 태양광 에어컨 시스템에 관한 연구 (A study of residential solar airconditioning system using bidirectional PWM converter)

  • 유권종;송진수;황인호;김홍성;고재석;최규하;김한성
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.358-364
    • /
    • 1996
  • Recently, much power demand from domestic power consumer is weakening the allowable power reserve margin in summer, especially at midday for one day due to a steep increase of air cooling loads such as air conditioner. Therefore solar airconditioning system can'be considered as one of the best remedies to meet the increase of peak power. Generally in solar air conditioning system, the diode rectifier is used to build up DC link voltage from AC source. The diode rectifier is simple and cheap but it brings out the problems of low power factor and plentiful harmonics at the AC source. Also It can derate the utilization rate of solar energy because the reverse of power flow cannot be made. Hence, in this paper to overcome the peak power problem in summer and to endure good AC input characteristics, solar air conditioning system using the PWM converter is proposed. As results, obtained are the characteristics of the PWM converter such as low distorted current waveform, high power factor and bidirectional power control. And also the stability of proposed system is verified by examining the dynamics of step load change and power reversal testing. (author). refs., figs., tabs.

  • PDF

열판매 정보를 고려한 지역난방 수요 예측의 정확도 향상 (Accuracy Improvement in Demand Forecast of District Heating by Accounting for Heat Sales Information)

  • 신룡균;유호선
    • 플랜트 저널
    • /
    • 제15권1호
    • /
    • pp.31-37
    • /
    • 2019
  • 본 연구에서는 지역난방시스템 열수요 예측의 정확도 향상을 위하여 판교지역을 대상으로 지역난방 수요예측 주요인자 중 열수요 실적을 기존의 열원시설 열공급정보 대신 변경된 사용자시설 열판매정보로 적용하여 혹한기를 포함한 5개월 동안의 수요를 예측하고 실적값을 기준으로 기존 방식과 정확도를 비교하였다. 열수요가 피크를 이루는 혹한기 1주일(2018.01.08.~01.14) 동안 실적값을 기준으로 기존 및 변경방식 예측값의 시간대별 차이를 비교한 결과 상대오차가 7%에서 3%로 감소되었으며, 2017년 10월부터 2018년 2월까지 5개월에 걸친 일일 누적 열수요에 있어서도 실적값 대비 기존 및 변경 방식 예측값의 상대오차는 각각 9%와 4%로 변경방식의 상대오차가 감소하였다. 또한, 열수요 특성이 차별화되는 주말의 경우에도 예측값의 상대오차는 기존 방식 10%에서 변경 방식 5%로 일관성 있게 감소함을 확인할 수 있었다.

Single-Phase Multilevel PWM Inverter Based on H-bridge and its Harmonics Analysis

  • Choi, Woo-Seok;Nam, Hae-Kon;Park, Sung-Jun
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1227-1234
    • /
    • 2015
  • The efficient electric power demand management in electric power supply industry is currently being changed by distributed generation. Meanwhile, small-scale distributed generation systems using renewable energy are being constructed worldwide. Several small-scale renewable distributed generation systems, which can supply electricity to the grid at peak load of the grid as per policy such as demand response programs, could help in the stability of the electric power demand management. In this case, the power quality of the small-scale renewable distributed generation system is more significant. Low prices of power semiconductors and multilevel inverters with high power quality have been recently investigated. However, the conventional multilevel inverter topology is unsuitable for the small-scale renewable distributed generation system, because the number of devices of such topology increases with increasing output voltage level. In this paper, a single-phase multilevel inverter based on H-bridge, with DC_Link divided by bi-directional switches, is proposed. The proposed topology has almost half the number of devices of the conventional multilevel inverter topology when these inverters have the same output voltage level. Double Fourier series solution is mainly used when comparing PWM output harmonic components of various inverter topologies. Harmonic components of the proposed multilevel inverter, which have been analyzed by double Fourier series, are compared with those of the conventional multilevel inverter. An inverter prototype is then developed to verify the validity of the theoretical analysis.

스마트그리드 기반의 실시간요금제 및 DR운영시스템 구현 (A Development of Demand Response Operation System and Real-Time Pricing based on Smart Grid)

  • 고종민;송재주;김영일;정남준;김상규
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1964-1970
    • /
    • 2010
  • A new intelligent power network (Smart Grid) that grafts some new technologies, such as the extension of the new and reproducible energy, electric motors, and electric storages, onto the regulation of green house gases according to the recent convention on climate changes has been actively promoted. As establishing such an intelligent power network, it is possible to implement a real-time rate system according to the change from the conventional single directional information transmission to the bidirectional information transmission. Such a real-time rate system can provide power during the chip rate hour by avoiding the high rate hour although customers use the same level of power through providing such real-time rate information including power generation costs. In this study, the establishment of an operating system that makes an effective use of the real-time rate system and its operation method are to be proposed.