• Title/Summary/Keyword: Patient Prescription

Search Result 423, Processing Time 0.031 seconds

Effect of Community-Based Interventions for Registering and Managing Diabetes Patients in Rural Areas of Korea: Focusing on Medication Adherence by Difference in Difference Regression Analysis (한 농촌 지역사회 기반 당뇨병 환자의 등록관리 중재의 효과: 투약순응도에 대한 이중차이분석을 중심으로)

  • Hyo-Rim Son;So Youn Park;Hee-Jung Yong;Seong-Hyeon Chae;Eun Jung Kim;Eun-Sook Won;Yuna Kim;Se-Jin Bae;Chun-Bae Kim
    • Health Policy and Management
    • /
    • v.33 no.1
    • /
    • pp.3-18
    • /
    • 2023
  • Background: A chronic disease management program including patient education, recall and remind service, and reduction of out-of-pocket payment was implemented in Korea through a chronic care model. This study aimed to assess the effect of a community-based intervention program for improving medication adherence of patients with diabetes mellitus in rural areas of Korea. Methods: We applied a non-equivalent control group design using Korean National Health Insurance Big Data. Hongcheon County has been continuously adopting this program since 2012 as an intervention region. Hoengseong County did not adopt such program. It was used as a control region. Subjects were a cohort of patients with diabetes mellitus aged more than 65 years but less than 85 years among residents for 11 years from 2010 to 2020. After 1:1 matching, there were 368 subjects in the intervention region and 368 in the control region. Indirect indicators were analyzed using the difference-in-difference regression according to Andersen's medical use model. Results: The increasing percent point of diabetic patients who continuously received insurance benefits for more than 240 days from 2010 to 2014 and from 2010 to 2020 were 2.6%p and 2.7%p in the intervention region and 3.0%p and 3.9%p in the control region, respectively. The number of dispensations per prescription of diabetic patient in the intervention region increased by approximately 4.61% by month compared to that in the control region. Conclusion: The intervention program encouraged older people with diabetes mellitus to receive continuous care for overcoming the rule of halves in the community. More research is needed to determine whether further improvement in the continuity of comprehensive care can prevent the progression of cardiovascular diseases.

Contralateral Breast Doses Depending on Treatment Set-up Positions for Left-sided Breast Tangential Irradiation (좌측 유방암 환자의 방사선 치료 시 환자자세에 따른 반대편 유방의 산란선량 측정)

  • Joo, Chan Seong;Park, Su Yeon;Kim, JongSik;Choi, Byeong Gi;Chung, Yoonsun;Park, Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.175-181
    • /
    • 2015
  • Purpose : To evaluate Contralateral Breast Doses with Supine and Prone Positions for tangential Irradiation techniques for left-sided breast Cancer Materials and Methods : We performed measurements for contralateral doses using Human Phantom at each other three plans (conventional technique, Field-in-Field, IMRT, with prescription of 50 Gy/25fx). For the measurement of contralateral doses we used Glass dosimeters on the 4 points of Human Phantom surface (0 mm, 10 mm, 30 mm, 50 mm). For the position check at every measurements, we had taken portal images using EPID and denoted the incident points on the human phantom for checking the constancy of incident points. Results : The contralateral doses in supine position showed a little higher doses than those in prone position. In the planning study, contralateral doses in the prone position increased mean doses of 1.2% to 1.8% at each positions while those in the supine positions showed mean dose decreases of 0.8% to 0.9%. The measurements using glass dosimeters resulted in dose increases (mean: 2.7%, maximum: 4% of the prescribed dose) in the prone position. In addition, the delivery techniques of Field-in-field and IMRT showed mean doses of 3% higher than conventional technique. Conclusion : We evaluated contralateral breast doses depending on different positions of supine and prone for tangential irradiations. For the phantom simulation of set-up variation effects on contralateral dose evaluation, although we used humanoid phantom for planning and measurements comparisons, it would be more or less worse set-up constancy in a real patient. Therefore, more careful selection of determination of patient set-up for the breast tangential irradiation, especially in the left-sided breast, should be considered for unwanted dose increases to left lung and heart. In conclusion, intensive patient monitoring and improved patient set-up verification efforts should be necessary for the application of prone position for tangential irradiation of left-sided breast cancer.

  • PDF

Estimation of Fetal Dose during Radiation Therapy of Pregnant Patient (임산부의 방사선치료 시 태아선량 평가)

  • Jung, Chi-Hoon;Kim, Chan-Yong;Kim, Bo-Gyum;Seo, Suk-Jin;Yoo, Sook-Hyun;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Purpose: To evaluate the effectiveness of a simple and practical shielding device to reduce the fetal dose for a pregnant patient undergoing radiation therapy of brain metastasis. Materials and Methods: The dose to the fetus was evaluated by simulating the treatments using the anthropomorphic phantom. The prescription dose at mid-brain is $300cGy{\times}10$ fractions with 6 MV photon with $18{\times}22cm^2$ field size. The additional shielding devices to reduce the fetal dose are a shielding wall, cerrobend plates and lead (Pb) sheets over acrylic bridge. Various points of measurement with off-field distance were detected by using ion-chamber (30, 40, 50, and 60 cm) with and without the shielding devices and TLD (30, 40, 50, 60, and 70 cm) only with the shielding devices. Results: The doses to the fetus without shielding were 3.20, 3.21, 1.44, 0.90 cGy at the distances of 30, 40, 50, and 60 cm from the treatment field edge. With shielding, the doses were reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy (70 cm). The total dose to the fetus was expected to be under 1 cGy during the entire treatment. Conclusion: The essential point during radiation therapy of pregnant patient would be minimizing the fetal dose. 10 cGy to 20 cGy is the threshold dose for fetal radiation effects. Our newly developed device reduced the fetal dose far below the safe level. Therefore, our additional shielding devices are useful and effective to reduce the fetal dose.

  • PDF

A study on dosimetric comparison of craniospinal irradiation using tomotherpy and reproducibility of position (토모테라피를 이용한 뇌척수조사의 선량적 비교와 자세 재현성에 대한 고찰)

  • Lee, Heejeong;Kim, Jooho;Lee, Sangkyu;Yoon, Jongwon;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.69-76
    • /
    • 2017
  • Purpose: The purpose of this study was to verify dosimetric results and reproducibility of position during craniospinal irradiation (CSI) using tomotherapy (Accuray Incorporated, USA). Also, by comparing with conventional CSI Technique, we confirmed the efficiency of using a Tomotherapy. Materials and Methods: 10 CSI patients who get tomotherapy participate. Patient-specific quality assurances (QA) for each patient are conducted before treatment. When treating, we took Megavoltage Computed Tomography (MVCT) that range of head and neck before treatment, L spine area after treatment. Also we conducted in-vivo dosimetry to check a scalp dose. Finally, we made a 3D conventional radiation therapy(3D-CRT) of those patients to compare dosimetric differences with tomotherapy treatment planning. Results: V107, V95 of brain is 0 %, 97.2 % in tomotherapy, and 0.3 %, 95.1 % in 3D-CRT. In spine, value of V107, V95 is 0.2 %, 18.6 % in tomotherapy and 89.6 %, 69.9 % in 3D-CRT. Except kidney and lung, tomotherapy reduced normal organ doses than 3D-CRT. The maximum positioning error value of X, Y, Z was 10.2 mm, -8.9 mm, -11.9 mm. Through in-vivo dosimetry, the average of scalp dose was 67.8 % of prescription dose. All patient-specific QA were passed by tolerance value. Conclusion: CSI using tomotherapy had a risk of parallel organ such as lung and kidney because of integral dose in low dose area. However, it demonstrated dosimetric superiority at a target and saved normal organ to reduce high dose. Also results of reproducibility were not exceeded margins that estimated treatment planning and invivo dosimetry showed to reduce scalp dose. Therefore, CSI using tomotherapy is considered to efficient method to make up for 3D-CRT.

  • PDF

A Study on Intracavitary Therapy in Cervix Cancer Using Needle for Interstitial Therapy (조직 내 삽입용 바늘을 이용한 자궁경부암의 강내치료에 관한 연구)

  • Cho, Jung-Keun;Jung, Hong-Ryang;Lim, Cheong-Hwan;Kim, Jeong-Koo;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.83-92
    • /
    • 2006
  • Based on the data of cervical cancer patients who were treated by the radiotherapy with concurrent chemotherapy at the radiation oncology department of National Cancer Center from January 2002 to February 2003, we have studied the method recommended by ICRU 38 to maximize the prescription dose to the planing target volume (PTV) with minimizing the dose to surrounding normal organs. Clinical stage of the patients are 1 patient for stage IB, 3 patients for IIA, 19 patients for IIB, 3 patients for IIIA, 3 patients for IIIB and 1 patient for IV. All patients took the MRI before treatment and the maximum size of the gross tumor volume were under 4cm for 17 patients and from 4 cm to 6 cm for 12 patients and above 6 cm for 1 patient. The results show that while the irradiated volume can be reduced with optimized dose distribution using PTV treatment planning (p<0.0001) when the remained tumor size is small, the surrounding normal organs will receive unnecessarily large dose when the irradiated tumor volume is relatively large. This is because there is some limitation in controling the intensity of radiation in Fletcher Williamson Applicator. To overcome the limit of applicator and to achieve the optimal dose distribution, we have virtually applied 4 needles with Fletcher Williamson Applicator for 10 patients who have relatively large tumor and studied the change in dose distribution before and after application. The results show that this new virtual treatment plan reduces the volume covered by 100 % isodose (p=0.0608, p=0.0607) and reduces the dose of normal organs (p=0.0162, p=0.008). This evidence suggest that this method is superior than the currently used method such as PTV treatment and ICRU treatment.

  • PDF

Strategic Direction and Road Map of Expanding Prevention of Winter Disease in the Summer (동병하치 확산을 위한 전략적 방향과 이행방안)

  • Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.27 no.3
    • /
    • pp.147-157
    • /
    • 2010
  • Objectives : The purpose of this study was to propose appropriate strategic directions and road maps for successful achievement of programs preventing winter disease in the summer. Methods : Details on programs preventing winter disease in the summer such as clear concept, theoretical basis, current status, intervention or available prescriptions and indication/contraindication/caution were prepared through the related journal review, upon which an observational study was devised and done for simulation to find out even a trivial problem and to guarantee the safety beforehand. The experimental group was divided into 5 groups by the size of pill and the way ginger is treated; 1cm pill with ginger group, 3cm pill group without ginger, 3cm pill group dipped into ginger, 3cm pill group applying ginger to acupoints and 3cm pill group with ginger Results 1. program preventing winter disease in the summer was defined as representative winter diseases such as common cold, influenza, chronic asthma, chronic bronchitis, allergic rhinitis, emphysema, chronic gastritis and rheumatoid arthritis, and preventive care in the summer, reinforcing deficient yang qi of five viscera by using exuberant yang qi from summer heat. 2. It was based upon historically established theories which is 'nourishing yang qi in the spring and summer', 'long summer, namely rainy spell in the summer overwhelms the winter, because of earth winning water according to the five phases theory' and 'To replenish yang qi is major principle to treat winter diseases, which can be most appropriately and timely applied to the patient with deficient yang qi of five viscera inherently, especially in the three dog days of the summer, because of exuberant exterior yang qi and deficient interior yang qi in the five viscera'. 3. In the adjacent China and Taiwan, acupoint applying method in the three dog days named 'San Fu Tie' have been stirring a boom throughout the nation, in which Xiaochuan Gao was used as a basic prescription and it mainly was applied at bilateral $BL_{13}$, $_{15}$ and $_{17}$ for about 4 hours. As far as domestic current status, the necessity of adopting the above method prior to Herbal formula was also recognised, because not a few koreans have apprehension for the safety of it including medicinal herbs and are reluctant to take it any more due to negative advertisement of narrow minded doctors' association. 4. Indication of acupoint applying method in the three dog days included most of winter diseases such as common cold, influenza, chronic asthma, chronic bronchitis, allergic rhinitis, emphysema, chronic gastritis. contraindication was pregnant woman and the weak such as infants and the old. More attention was paid to grasp firmly the normal reaction following the treatment for preventing side effect and teasing blister. recommendation was also given to abstain from food inducing phlegm and dampness such as meat, shrimp and crab as well as cold drinks and foods 5. In the simulation observational study based upon the above findings following review the related articles, no blister was shown on the acupoints icluding bilateral $BL_{13}$, $_{15}$ and $_{17}$ in every experimental group during 24hr observation following the acupoint applying treatment with pills made by modified and devised prescription. At 4 hr, the effectiveness of it reached a peak showing redness and mild tenderness and there is little difference between groups 3cm pills groups regardless of the way ginger was treated. abdominal distention and growling was found in all the volunteers during the treatment at CV 8. Strategic directions and road maps : Through successful fulfillment of the program preventing winter disease in the summer, Korean traditional medicine should be integrated into mainstream national health care services. Cultural access was thought to be as important as Scientific EBM approach. First of all, To evoke potential cultural homogeneity from campaigns and press advertisement was needed for promoting public awareness about preventing winter disease in the summer by enhancing immunity via acupoint applying treatment in the three dog days, and then indigenous name as Sambokcheop, protocol, Clinical Research Form for data collection of it should be developed and prepared. Once the first step was taken this summer, through a thorough data collection and scrutinized scientific evaluation, drawbacks should be compensted for and the efficacy and safety should be substantiated.

Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation (전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용)

  • Park, Seung-Jin;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1994
  • Purpose : This study was performed to verify dose distribution with the tissue compensator which is used for uniform dose distribution in total body irradiation(TBI). Materials and methods : The compensators were made of lead(0.8mm thickness) and aluminum(1mm or 5mm thickness) plates. The humanoid phantom of adult size was made of paraffin as a real treatment position for bilateral total body technique. The humanoid phantom was set at 360cm of source-axis distance(SAD) and irradiated with geographical field size(FS) $144{\times}144cm^2(40{\times}40cm^2$ at SAD 100cm) which covered the entire phantom. Irradiation was done with 10MV X-ray(CLINAC 1800, Varian Co., USA) of linear accelerator set at Department of Therapeutic Radiology, Chonnam University Hospital. The midline absorbed dose was checked at the various regions such as head, mouth, mid-neck, sternal notch, mid-mediastinum, xiphoid, umbilicus, pelvis, knee and ankle with or without compensator, respectively. We used exposure/exposure rate meter(model 192, Capintec Inc., USA) with ionization chamber(PR 05) for dosimetry, For the dosimetry of thorax region TLD rods of $1x1x6mm^3$ in volume(LiF, Harshaw Co., Netherland) was used at the commercially available humanoid phantom. Results : The absorbed dose of each point without tissue compensator revealed significant difference(from $-11.8\%\;to\;21.1\%$) compared with the umbilicus dose which is a dose prescription point in TBI. The absorbed dose without compensator at sternal notch including shoulder was $11.8\%$ less than the dose of umbilicus. With lead compensator the absorbed doses ranged from $+1.3\%\;to\;-5.3\%$ except mid-neck which revealed over-compensation($-7.9\%$). In case of aluminum compensator the absorbed doses were measured with less difference(from $-2.6{\%}\;to\;5.3\%$) compared with umbilicus dose. Conclusion : Both of lead and aluminum compensators applied to the skull or lower leg revealed a good compensation effect. It was recognized that boost irradiation or choosing reference point of dose prescription at sternal notch according to the lateral thickness of patient in TBI should be considered.

  • PDF

Changing Trends in the Occurrence and Management of Delirium for 5 Years in a University Hospital (일 대학병원에서 5개년간 섬망의 발생 및 치료 경향의 변화)

  • Bae, Jae Ho;Kang, Won Sub;Paik, Jong Woo;Kim, Jong Woo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.20 no.2
    • /
    • pp.112-119
    • /
    • 2012
  • Objectives : Delirium is a disorder defined as a sudden disturbance in thinking, speaking, acting and sleep pattern due to altered level of consciousness and cognitive function. The objective of this study is to analyze characteristics and therapeutic methods of the delirious patients during the recent 5 years, and provide basic data for further studies and investigation regarding delirium in the occurrence and treatment. Methods : We retrospectively reviewed medical records of 475 patients who were consulted for delirium in Kyunghee University Medical Center from January 2007 to December 2011. Results : During the 5 years, among the 475 patients who were diagnosed as delirium, men were more common(61.7%). The most commonly consulted reason and cause were sleep disturbance(80.8%) and post-operational delirium(30.9%), respectively. The medication prescription percentage was 76.6% and was significantly increased year after year. Ratio of using antipsychotics were 76.4% among prescribed medication and the most frequently prescribed antipsychotic drug was quetiapine(46.8%). Other specialists commonly misdiagnosed delirium when the patient was previously diagnosed as dementia(6.8%). Conclusions : In our study, post-operational delirium was the most commonly referred reason and the percentage of medication prescription tended to increase. Patients with history of dementia were more easily misdiagnosed as diseases other than delirium. Our study suggests that we should evaluate symptoms, causes, reasons of consultation, management tendency of delirium. We should also closely observe changes in sleep patterns and establish the prevention strategies for post-operational delirium and therapeutic bases for pharmacotherapy.

  • PDF

Accuracy evaluation of treatment plan according to CT scan range in Head and Neck Tomotherapy (두경부 토모테라피 치료 시 CT scan range에 따른 치료계획의 정확성 평가)

  • Kwon, Dong Yeol;Kim, Jin Man;Chae, Moon Ki;Park, Tae Yang;Seo, Sung Gook;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.13-24
    • /
    • 2019
  • Purpose: CT scan range is insufficient for various reasons in head and neck Tomotherapy®. To solve that problem, Re-CT simulation is good because CT scan range affects accurate dose calculations, but there are problems such as increased exposure dose, inconvenience, and a change in treatment schedule. We would like to evaluate the minimum CT scan range required by changing the plan setup parameter of the existing CT scan range. Materials and methods: CT Simulator(Discovery CT590 RT, GE, USA) and In House Head & Neck Phantom are used, CT image was acquired by increasing the image range from 0.25cm to 3.0cm at the end of the target. The target and normal organs were registered in the Head & Neck Phantom and the treatment plan was designed using ACCURAY Precision®. Prescription doses are Daily 2.2Gy, 27 Fxs, Total Dose 59.4Gy. Target is designed to 95%~107% of prescription dose and normal organ dose is designed according to SMC Protocol. Under the same treatment plan conditions, Treatment plans were designed by using five methods(Fixed-1cm, Fixed-2.5cm, Fixed-5cm, Dynamic-2.5cm Dynamic-5cm) and two pitches(0.43, 0.287). The accuracy of dose delivery for each treatment plan was analyzed by using EBT3 film and RIT(Complete Version 6.7, RIT, USA). Results: The accurate treatment plan that satisfying the prescribed dose of Target and the tolerance dose in normal organs(SMC Protocol) require scan range of at least 0.25cm for Fixed-1cm, 0.75cm for Fixed-2.5cm, 1cm for Dynamic-2.5cm, and 1.75cm for Fixed-5cm and Dynamic-5cm. As a result of AnalysisAnalysis by RIT. The accuracy of dose delivery was less than 3% error in the treatment plan that satisfied the SMC Protocol. Conclusion: In case of insufficient CT scan range in head and neck Tomotherapy®, It was possible to make an accurate treatment plan by adjusting the FW among the setup parameter. If the parameter recommended by this author is applied according to CT scan range and is decide whether to re-CT or not, the efficiency of the task and the exposure dose of the patient are reduced.

A Clinical Study of Soeumin Doksamkwankaeijungtang (독삼관계이중탕(獨參官桂理中湯)의 소음인(小陰人) 인후통(咽喉痛) 치험례(治驗例))

  • Huh, Manhn-hoi;Song, Il-byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.1
    • /
    • pp.240-259
    • /
    • 2000
  • 1. Background and Purpose I intented to be helpful to understand the consitutional symptoms of soar throat and the application of the prescription through a clinical study of Soeumin Doksamkwankaeijungtang. 2. Methods I studied 16 patients(1 man and 15 women) treated by Doksamkwankaeijungtang in Chewon Oriental Clinic. And then I investigated the characteristics of patients treated by Doksamkwankaeijungtang, remedial values and side effects. 3. Results Doksamkwankaeijungtang was used in the age groups between twenties and sixties. There were 28 kinds of chief complaints including soar throat, tonsilitis, allergic rheum, bitter taste, dry throat, dry cough, stomatitis, lower abdominal pains, climacteric syndrome, etc. The distributions of remedial values were completely recovered (56.25%), much improved (18.75%), slightly improved(6.25%), no improved(12.5%), aggravated(6.25%), side effects(18.75%). There was one aggravated patient. Using the prescription, I prescribed it without any changing and addition according to the symptoms of soar throat. The remedial value of Doksamkwankaeijungtang was effective and not influenced by the dosage of Ginseng. The onset of action was very quick by the changes of dosage without the relation of age. Side effects were upward tendency of blood presser, headache, chest pain, etc. 4. Conclusion Doksamkwankaeijungtang was specifically effective in soar throat of Soeumin.

  • PDF