• 제목/요약/키워드: Passive operation.

검색결과 407건 처리시간 0.026초

고출력 MHL용 구형저주파 구동 방식의 전자식 안정기 설계 (Electronic Ballast Design Driven by Low Frequency Square Wave for High Power MHL)

  • 김기남;박종연;최영민
    • 전력전자학회논문지
    • /
    • 제15권5호
    • /
    • pp.394-400
    • /
    • 2010
  • 본 논문에서는 Buck Converter 동작 원리를 Full -Bridge Inverter에 적용한 전자식 안정기를 제안하였다. 전자식안정기는 EMI 필터, 수동 PFC, Full-Bridge Inverter로 2-stage로 구성되어 있다. PFC는 신뢰성 확보를 위해 수동 PFC를 사용하였다. Full-Bridge Inverter는 High Side와 Low Side 스위치의 구동 주파수를 각각 고주파와 저주파로 구동하여 Buck Converter의 동작을 구현 하였다. 램프를 저주파수 구형파로 구동하여 음향공명현상을 피하게 되었으며, 고주파수 스위칭으로 인덕터의 부피를 줄였다. 제안한 방법은 시뮬레이션과 실험을 통해 증명하였다.

Analysis and Implementation of a New Single Switch, High Voltage Gain DC-DC Converter with a Wide CCM Operation Range and Reduced Components Voltage Stress

  • Honarjoo, Babak;Madani, Seyed M.;Niroomand, Mehdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.11-22
    • /
    • 2018
  • This paper presents a single switch, high step-up, non-isolated dc-dc converter suitable for renewable energy applications. The proposed converter is composed of a coupled inductor, a passive clamp circuit, a switched capacitor and voltage lift circuits. The passive clamp recovers the leakage inductance energy of the coupled inductor and limits the voltage spike on the switch. The configuration of the passive clamp and switched capacitor circuit increases the voltage gain. A wide continuous conduction mode (CCM) operation range, a low turn ratio for the coupled inductor, low voltage stress on the switch, switch turn on under almost zero current switching (ZCS), low voltage stress on the diodes, leakage inductance energy recovery, high efficiency and a high voltage gain without a large duty cycle are the benefits of this converter. The steady state operation of the converter in the continuous conduction mode (CCM) and discontinuous conduction mode (DCM) is discussed and analyzed. A 200W prototype converter with a 28V input and a 380V output voltage is implemented and tested to verify the theoretical analysis.

Problems and improvement methods of passive treatment systems for acid mine drainage in Korea

  • Ji, Sang-Woo;Ko, Ju-In;Kim, Sun-Joon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.504-510
    • /
    • 2003
  • This study has been carried out to evaluate the passive treatment systems for acid mine drainage in Korea and to suggest, if possible, the method for the improvement. 35 passive treatment systems in 27 mines have been constructed since 1996. SAPS, being the main process, was combined with more than one of processes such as anaerobic wetland, aerobic wetland, and oxidation pond for the construction of passive treatment system. Problems observed during the operation include the poor sulfate removal ratio, overflow, leakage, unusabless of the whole system, and inefficiency. The reasons of the poor sulfate removal ratio are believed that the low temperature during the winter prohibits the SRB activity and HRT for bacterial sulfate reduction is insufficient. An alternative method In Adit Sulfate Reducing System which enables to keep the temperature constant at about $15^{\circ}C$ was suggested. IASRS is the methods of placing the SAPS inside the adit, which enables the temperature around the system constant can be maintained. The experiments using the laboratory scaled model systems made up of four sections showed high efficiencies in pH control and metal removal ratios, but showed still low sulfate removal ratio of about $23\%$ also with high COD at the beginning of the operation.

  • PDF

Advanced Reactor Passive System Reliability Demonstration Analysis for an External Event

  • Bucknor, Matthew;Grabaskas, David;Brunett, Acacia J.;Grelle, Austin
    • Nuclear Engineering and Technology
    • /
    • 제49권2호
    • /
    • pp.360-372
    • /
    • 2017
  • Many advanced reactor designs rely on passive systems to fulfill safety functions during accident sequences. These systems depend heavily on boundary conditions to induce a motive force, meaning the system can fail to operate as intended because of deviations in boundary conditions, rather than as the result of physical failures. Furthermore, passive systems may operate in intermediate or degraded modes. These factors make passive system operation difficult to characterize within a traditional probabilistic framework that only recognizes discrete operating modes and does not allow for the explicit consideration of time-dependent boundary conditions. Argonne National Laboratory has been examining various methodologies for assessing passive system reliability within a probabilistic risk assessment for a station blackout event at an advanced small modular reactor. This paper provides an overview of a passive system reliability demonstration analysis for an external event. Considering an earthquake with the possibility of site flooding, the analysis focuses on the behavior of the passive Reactor Cavity Cooling System following potential physical damage and system flooding. The assessment approach seeks to combine mechanistic and simulation-based methods to leverage the benefits of the simulation-based approach without the need to substantially deviate from conventional probabilistic risk assessment techniques. Although this study is presented as only an example analysis, the results appear to demonstrate a high level of reliability of the Reactor Cavity Cooling System (and the reactor system in general) for the postulated transient event.

자연형 및 설비형 태양열 온수기의 집열특성에 대한 실험적 연구 (The Experimental Research for the Collecting Characteristics of the Passive and Active type Domestic Solar Hot Water Systems)

  • 이동원;이경호
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.12-18
    • /
    • 2013
  • Domestic solar hot water system can be divided into a passive type and an active type. In a passive type the storage tank is horizontally mounted immediately above the solar collectors. No pumping is required as the hot water naturally rises into the storage tank from the collectors through thermo-siphon flow. While, in an active type the storage tank is ground- or floor-mounted and is below the level of the collectors; a circulating pump moves water or heat transfer fluid between the storage tank and the collectors. We installed two types solar hot water systems consisting of the same storage tank and collectors at the same place, and were measured and compared typical operating characteristics under the same external conditions. In particular, the daily system performance was presented through the stirring test after the sunset. The results show that the amount of solar radiation obtained for an active type were less than a passive type on a cloudy day, because the operation of the circulation pump stops frequently took place on that day. However, on a sunny day, depending on the stable operation of the circulation pump, the amount of solar radiation obtained for an active type were increased than a passive type.

Soft-Switching Boost Chopper Type DC-DC Power Converter with a Single Auxiliary Passive Resonant Snubber

  • Nakamura Mantaro;Myoui Takeshi;Abudullh Al Mamun;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.256-260
    • /
    • 2001
  • This paper presents boost and buck and buck-boost DC-DC converter circuit topologies of high-frequency soft switching transition PWM chopper type DC-DC high power converters with a single auxiliary passive resonant snubber. In the proposed boost power converter circuits operating under a principle of ZCS turn-on and ZVS turn-off commutation schemes, the capacitor and inductor in the auxiliary passive resonant circuit works as the loss less resonant snubber. In addition to this, the switching voltage and current peak stresses as well as EMI and RFI noises can be basically reduced by this single passive resonant snubber. Moreover, it is proved that converter circuit topologies with a passive resonant snubber are capable of solving some problems of the conventional hard switching PWM processing based on high-ferquency pulse modulation operation principle. The simulation results of this converter are discussed as compared with the experimental ones. The effectiveness of this power converter with a single passive resonant snubber is verified by the 5kW experimental breadboad set up.

  • PDF

고조파 저감을 위한 수동필터의 제어시스템에 관한 연구 (A Study on the Control System of Passive Filter to Reduce Harmonics)

  • 전정채;유재근;이상익
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.124-130
    • /
    • 2004
  • 본 논문에서는 고조파 저감을 위해 사용하는 수동필터를 부하의 운전조건에 따라 자동으로 개$.$폐할 수 있는 DSP 기반의 제어시스템을 개발하였다. 수동필터 제어시스템은 부하에서 발생하는 전압, 전류, 고조파, 무효전력, 역률 등을 측정 및 감시하여 수동필터 개ㆍ폐 장치에 신호를 보내어 부하의 운전조건에 따라 필터의 각 분로를 자동으로 개$.$폐하게 된다. 이러한 제어시스템을 100마력 직류전동기 구동장치를 사용하는 계통에 수동필터와 함께 설치하고 전동기 운전조건에 따라 수동필터를 개$.$폐시키며 고조파 및 무효전력 등을 측정함으로써 성능을 입증하였다.

Design of Passive Treatment Systems for Mine Drainage Waters

  • Jeen, Sung-Wook
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권2호
    • /
    • pp.1-9
    • /
    • 2017
  • Passive treatment systems are commonly used for remediation of mine drainage waters because they do not require continuous chemical inputs and operation. In this study, the selection and design criteria for such systems were evaluated, particularly the two most commonly used ones, i.e., permeable reactive barriers (PRBs) and vertical flow biological reactors (VFBRs). PRBs and VFBRs are operated on the same principles in terms of biochemical reaction mechanisms, whereas differences relate to configuration, engineering, and water management. In this study, each of these systems were described with respect to key design variables, such as metal removal mechanisms and removal rates, effectiveness and longevity, general design and construction, flow capacity, and cost. The information provided from this study could be used as a design guideline when a passive treatment option is considered for potential remediation of a mine site.

저잡음 특성의 광대역 비간섭성 광원과 파장 분할 다중방식 수동형 광가입자망에의 응용 (A Low Noise Broadband Light Source and its Application on WDM-PON)

  • 최기만;문정형;이창희
    • 대한전자공학회논문지TC
    • /
    • 제43권5호
    • /
    • pp.68-76
    • /
    • 2006
  • 본 논문에서는 저잡음 특성을 지닌 광대역 비간섭성 광원 (BLS: Broadband Light Source)을 제안하고 이를 방송 및 통신의 통합 서비스를 제공하는 파장 분할 다중방식 수동형 광 가입자망 (WDM-PON: Wavelength Division Multiplexing-Passive Optical Network)에 적용함으로써 경제적인 광가입자망의 가능성을 시험하였다. 제안된 BLS는 경제적인 WDM-PON용 광원인 파장 잠김된 패브리 페롯 레이저 다이오드 (wavelength-locked F-P LD: wavelength-locked Fabry-Perot Laser Diode)를 위한 외부 주입 광원으로 사용되어 파장 무의존성 (color-free operation, i.e., wavelength independent operation)을 지닌 고밀도 WDM-PON (DWDM-PON: Dense WDM-PON)의 구현을 가능하게 한다. 또한 오버레이 (overlay) 방식의 방송 서비스를 위한 광원으로 응용되어 영상 및 화상 중심으로 융합된 서비스를 효율적으로 수용할 수 있는 광대역 통합망의 가능성을 시험하였다.

DEVELOPMENT OF AN OPERATION STRATEGY FOR A HYBRID SAFETY INJECTION TANK WITH AN ACTIVE SYSTEM

  • JEON, IN SEOP;KANG, HYUN GOOK
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.443-453
    • /
    • 2015
  • A hybrid safety injection tank (H-SIT) can enhance the capability of an advanced power reactor plus (APR+) during a station black out (SBO) that is accompanied by a severe accident. It may a useful alternative to an electric motor. The operations strategy of the H-SIT has to be investigated to achieve maximum utilization of its function. In this study, the master logic diagram (i.e., an analysis for identifying the differences between an H-SIT and a safety injection pump) and an accident case classification were used to determine the parameters of the H-SIT operation. The conditions that require the use of an H-SIT were determined using a decision-making process. The proper timing for using an H-SIT was also analyzed by using the Multi-dimensional Analysis of Reactor Safety (MARS) 1.3 code (Korea Atomic Energy Research Institute, Daejeon, South Korea). The operation strategy analysis indicates that a H-SIT can mitigate five types of failure: (1) failure of the safety injection pump, (2) failure of the passive auxiliary feedwater system, (3) failure of the depressurization system, (4) failure of the shutdown cooling pump (SCP), and (5) failure of the recirculation system. The results of the MARS code demonstrate that the time allowed for recovery can be extended when using an H-SIT, compared with the same situation in which an H-SIT is not used. Based on the results, the use of an H-SIT is recommended, especially after the pilot-operated safety relief valve (POSRV) is opened.