• 제목/요약/키워드: Partial discharge source

검색결과 98건 처리시간 0.026초

전력용변압기에서 UHF 부분방전 신호의 전파 특성 (Propagation Characteristics of Ultra High Frequency Partial Discharge Signals in Power Transformer)

  • 윤진열;한기선;주형준;구선근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.798-803
    • /
    • 2010
  • This paper describes the characteristics of electromagnetic wave propagation in power transformer. A transformer which is similar to 154 kV single phase on-site transformer unit was provided for the purpose of the experiment. The 12 dielectric windows on the transformer enclosure to install UHF (ultra high frequency) sensors and the full scale mock ups of winding and the core were also equipped in the transformer. Every sensors to be installed to the transformer was tested and verified whether they show same characteristics or not before the experiment. A discharge gap which was used as a PD (partial discharge) source moved to several necessary locations in the transformer to simulate dielectric defects. Propagation times of electromagnetic wave signal from PD source to sensors decided by the routes of both reflection phenomenon and diffraction phenomenon were compared each other. The experimental results showed propagation route of the PD signal makes an effect on the frequency spectrum of front part of the signal and the magnitude of the signal and propagation time of the signal when the signal is captured on the sensor.

PMOS 소자가 삽입된 부분웰 구조의 N형 SCR 소자에서 정전기 보호 성능 향상을 위한 최적의 CPS 이온주입에 대한 연구 (Study on the Optimal CPS Implant for Improved ESD Protection Performance of PMOS Pass Structure Embedded N-type SCR Device with Partial P-Well Structure)

  • 양준원;서용진
    • 한국위성정보통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.1-5
    • /
    • 2015
  • PPS 소자가 삽입된 부분웰 구조의 N형 실리콘 제어 정류기(NSCR_PPS) 소자에서 정전기 보호 성능의 향상을 위한 CPS 이온주입조건의 최적화에 대해 연구하였다. 종래의 NSCR 표준소자는 on-저항, 스냅백 홀딩 전압 및 열적 브레이크다운 전압이 너무 낮아 정전기 보호소자의 필요조건을 만족시키지 못해 적용이 어려웠으나, 본 연구에서 제안하는 CPS 이온주입과 부분웰 이온주입을 동시에 적용한 변형 설계된 소자의 경우 스냅백 홀딩 전압을 동작전압 이상으로 증가시킬 수 있는 향상된 정전기 보호성능을 나타내어 고전압 동작용 마이크로 칩의 정전기보호 소자로 적용 가능함을 확인하였다.

이산 웨이브렛변환에 의한 부분방전패턴 분석 (The Analysis of Partial Discharges Pattern using Discrete Wavelet Transform)

  • 이현동;이광식;이동인
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.84-89
    • /
    • 2001
  • 본 논문은 다중 해상도 웨이브렛 변환을 이용하여 코로나 방전과 코로나방전 후 연면방전을 거치는 다중결함에 대한 방전전류펄스의 변화량을 시간 대역과 주파수 대역에서의 변화량을 분석하였다. 마더웨이브렛의 선정은 방전전류펄스의 형태를 고려하여 Daubechies 마더웨이브렛을 선정하였으며, 방전전류펄스는 이산 웨이브렛 변환을 이용하여 근사신호와 상세신호로 4단계까지 다중분해되었다. 이중 상세신호만을 이용하여 12개의 세그먼트로 나눈후 설정한 변수에 따라 그 패턴을 파악하였다. 그 결과 코로나 방전에서는 설정된 변수의 세그먼트 7, 8, 9, 10의 값이 방전의 진전에 따라 증가하였으므로 위상분포를 $210~330[^{\circ}]$분포를 특징지울 수 있고, 에폭시 절연체를 삽입한 다중결함에서는 연면방전의 특징에 기인하여 설정된 변수의 값이 대칭적인 패턴을 나타내었다.

  • PDF

GIS 부분방전 검출을 위한 UHF 신호측정법 현장 적용 (Partial Discharge Detection on Site GIS Using UHF Technique)

  • 윤진열;박기준;구선근;조성훈;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1915-1917
    • /
    • 2000
  • Laboratory experiments and on site measurements were conducted to detect partial discharges in GIS(Gas Insulated Switchgear) using the UHF(Ultra High Frequency) technique that has been applied many places in the world. Experimental results were in good agreement with calculation in locating a partial discharge source using mock-up GIS. Defect type and its location were inferred after a measurement on 345 kV GIS that showed some abnormal phenomenon. Precise examination inside the GIS coincided with the results inferred from the measurement. High reliability of UHF technique for site application was confirmed.

  • PDF

A New Directional Coupler Type Partial Discharge Sensor Installed on the Power Lead of Rotating Machine

  • Yi, Sang-Hwa;Hwang, Don-Ha;Park, Wee Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1769-1776
    • /
    • 2016
  • For on-line partial discharge (PD) monitoring of rotating machines, a novel sensor is proposed, which can be installed on the power lead inside the terminal box of the machine. The sensor has been designed to have high capacitance, and minimal reflection of measured pulses. As a sensitivity of the sensor, transfer impedance $Z_t$ has been measured and compared to conventional coupler-type sensors. A simple method is presented for measuring $Z_t$ of coupler sensors, using a vector network analyzer and a practical lead-cable of rotating machine. Through this method, it became possible to measure the $Z_t$ of coupler sensors including the installation environment of them. The $Z_t$ of the proposed sensor is higher than that of same sized other conventional couplers at frequencies between 30 and 92 MHz. Another sensitivity test has been performed using a PD calibrator as a test pulse source. The proposed sensor has higher measured peak voltage than the conventional coupler type sensors when the same charges were input.

UHF 부분방전 진단법에 의한 가스절연 개폐장치의 성능검증 (Performance Verification of the Gas Insulated Switchgear using UHF Partial Discharge Diagnosis Method)

  • 김정배;정재룡;김민수;송원표;김맹현;고희석;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.132-135
    • /
    • 2004
  • In generally, compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise. We can detect the real abnormality with several pC in GIS using UHF method. Recently, it has applied to use the external UHF sensor attached on spacer to GIS of existing substation. In this paper, we firstly described the technique of the partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity, the relationship of dBm-pC and diagnosis of the reason of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on 800kV GIS in domestic substation. rge diagnosis of GIS.

  • PDF

왕복동 압축기의 소음 및 진동 기여도 분석 (Coherence Analysis of Noise and Vibration For Reciprocating Compressor)

  • 이대성;황원걸;이유엽;임형은
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.875-880
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor. Through the use of multiple-input/single-output(MISO) mode1, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. As outputs, vibrations of compressor shell were measured at three positions; cylinder head, one near the suction line, and the top of upper shell. The partial coherence function and transfer function are obtained ken the measured data, and the results are observed in order to determine vibration source and its influence on the shell vibration.

  • PDF

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • 양상현;박노준;김충식;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

전력용 케이블 시편에서 전기트리 발생원에 따른 부분방전 분포 특성 및 발생원 분류기법 비교 (Analysis of PD Distribution Characteristics and Comparison of Classification Methods according to Electrical Tree Source in Power Cable)

  • 박성희;정해은;임기조;강성화
    • 한국전기전자재료학회논문지
    • /
    • 제20권1호
    • /
    • pp.57-64
    • /
    • 2007
  • One of the cause of insulation failure in power cable is well known by electrical treeing discharge. This is occurred for imposed continuous stress at cable. And this event is related to safety, reliability and maintenance. In this paper, throughout analysis of partial discharge(PD) distribution when occurring the electrical tree, is studied for the purpose of knowing of electrical treeing discharge characteristics according to defects. Own characteristic of tree will be differently processed in each defect and this reason is the first purpose of this paper. To acquire PD data, three defective tree models were made. And their own data is shown by the phase-resolved partial discharge method (PRPD). As a result of PRPD, tree discharge sources have their own characteristics. And if other defects (void, metal particle) exist internal power cable then their characteristics are shown very different. This result Is related to the time of breakdown and this is importance of cable diagnosis. And classification method of PD sources was studied in this paper. It needs select the most useful method to apply PD data classification one of the proposed method. To meet the requirement, we select methods of different type. That is, neural network(NN-BP), adaptive neuro-fuzzy inference system and PCA-LDA were applied to result. As a result of, ANFIS shows the highest rate which value is 98 %. Generally, PCA-LDA and ANFIS are better than BP. Finally, we performed classification of tree progress using ANFIS and that result is 92 %.

Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil

  • Park, Dae-Won;Jo, Hyang-Eun;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1468-1473
    • /
    • 2013
  • This paper dealt with the propagation characteristics of acoustic signals produced by partial discharges and the positioning of PD origin in insulation oil to develop insulation diagnostic techniques of oil-immerged transformers. Electrode systems such as needle to plane, plane to plane, and particle electrodes were fabricated to simulate some defects of power transformers. In addition, the frequency spectrum and propagation characteristics of acoustic signals with partial discharge (PD) in insulation oil were analyzed. Although there were differences based on the type of defect, the frequency spectra of the acoustic signals measured by wide and narrow band acoustic emission (AE) sensors were distributed in the range of 50 kHz-400 kHz. Therefore, a narrowband AE sensor is suitable for the diagnosis of oil-immersed power transformers. We could find the position of the PD source with an error margin of 10% in the experiments by calculating the position of the PD occurrence using the time difference of arrival measured by five AE sensors.