• Title/Summary/Keyword: Partial Key

Search Result 406, Processing Time 0.03 seconds

Multiple Digital Watermarking Framework for Joint-Creatorship Verification in VR Environment (VR 환경에서 공동 소유권 증명을 위한 다중 워터마킹 프레임워크)

  • Cho, Mi-Sung;Sohn, Yu-Seung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.2
    • /
    • pp.95-100
    • /
    • 2007
  • Virtual Reality(VR) data in VR environments like Manufacturing industries are often created jointly by many creators. It is then necessary to provide protection of the joint-creatorship and the creatorship of each participating creator. This paper proposes Multiple Digital Watermarking Framework(MDWF) to solve the problem of joint-creatorship. The proposed framework, MDWF, makes use of 3D private watermarking technology and a novel key sharing protocol for joint-creatorship verification. MDWF embeds 3D private multiple watermarks for the creatorship of each participating creators in a non-overlapping manner during the creation process. After key agreement of all private keys, MDWF embeds an additional 3D private watermark for the joint-creatorship. Therefore MDWF successfully handles the creatorship dispute among creators. That is, each participation creator can prove his/her partial creatorship as well as joint-creatorship by MDWF. In addition, MDWF can solve the collusion problems because shared secret key(SSK) can be made by every users.

First report of an aeolid nudibranch Flabellina athadona and an identification key for the genus Flabellina from Korea

  • Jung, Daewui;Park, Joong-Ki
    • The Korean Journal of Malacology
    • /
    • v.31 no.3
    • /
    • pp.249-252
    • /
    • 2015
  • An aeolid nudibranch species Flabellina athadona (Bergh, 1875) is newly recorded from Korean waters. This species is distinguished from other congeneric species by the following characteristics: translucent white body, deep orange colored digestive glands, plenty of white specks, and a reversed Y-shaped marking on the head between rhinophores and oral tentacles. In this report, we also provide an identification key for the genus Flabellina in Korea, photographs, and diagnostic characteristics of F. athadona. Molecular identification using mtDNA cox1 partial sequences is also provided to help differentiate F. athadona from some of its closely related congeneric species.

A STUDY OF PHOTOELASTIC STRESS ANALYSIS IN THE IMZ IMPLANT-NATURAL 700TH SUPPORTED FIXED PARTIAL DENTURE USING ATTACHMENT WITH OR WITHOUT RIGID CONNECTION (어태치먼트를 이용한 IMZ 임플랜트와 자연치의 연결시 고정유무의 연결형태에 따른 광탄성 응력분석에 관한 연구)

  • Kim, Jeong-Sun;Hwang, Young-Phil;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.130-143
    • /
    • 1995
  • The purpose of this study was to analyze the magnitude and distribution of stress using photoelastic model with the rigid connection using T-block attachment and non-rigid connection using key & keyway attachment. The vertical load of 16 Kg was applied on the central fossa of the tooth, the pontic and the implant, and the pattern and distribution under each condition was analyzed. The following results were obtained : 1. In case of vertical load on the central fossa of the implant, the stress was concentrated at the apex of the implant involving the mesial alveolar bone in both fixed partial denture with the rigid connection and that with the nonrigid connection and the stress concentration at the mesial cervical area of the implant was a little more in the nonrigid connection than in the rigid connection. 2. In case of vertical load on the central fossa of the pontic, the stress was concentrated at the apex of 2nd bicuspid in both 3 unit fixed partial denture with nonrigid connection and that with the rigid connection. The stress was more concentrated at the mesial alveolar bone of the implant, but the stress distribution at the natural teeth more favorable at the rigid connection than at the non-rigid connection in case of 4 unit fixed partial denture. 3. In case of vertical load of the central fossa of the 2nd bicuspid, much stress with 3 fringe order was observed at the apex of the 2nd bicuspid in the 3 unit fixed partial denture, but relatively even stress distribution was observed at the apex of the implant, the 1st and 2nd bicuspid, and the adjacent cuspid in the 4 unit fixed partial denture.

  • PDF

Fracture Resistance of Low Invasive Fixed Partial Dentures (수종 저 침습 고정성 국소의치의 수직하중에 대한 저항)

  • Choi, Jong-In;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.241-251
    • /
    • 2010
  • This study aims at contributing to the restorative dentistry by examining results in the vertical load test of four different low invasive fixed partial dentures. Based on a hypothesis on the right upper first molar is missing, three units of FPDs were made for the second premolar and the second molar abutment. that is, twelve metal dies and FPDs were made for resin bonded FPD and Two Key Bridges and Human Bridge without occlusal rest and Human Bridge with occlusal rest. By using universal test machine, the numerical maximum value were recorded during the vertical load test of each FPDs after the bonding process treated by Maxcem which is resin cement. The failure process and its result of prosthesis were also observed. The maximum load was 7,295 N, 4,729 N, 2,190 N, 3,073 N from groups of resin bonded FPD, Two Key Bridge, Human Bridge without occlusal rest and Human Bridge with occlusal rest respectively. There was a statistical significance among the groups of resin bonded FPD, Two Key Bridge and Human Brides. However, there was no significant difference between Human Bridge without occlusal rest and Human Bridge with occlusal rest. Regarding the failure of prosthesis, the groups of Resin Bonded FPD and Two Key Bridge showed that one of the abutment teeth in the both side of retention part was highly failed earlier than the other one (83.2% and 66.6% respectively). While, Human Bridge without occlusal rest and Human Bridge with occlusal rest showed high percentage of failure in the abutment teeth in the both side of retention part at the same time (91.6% and 58.3% respectively). This study demonstrates that the group of Human Bridges has low resistance to the vertical loads of low invasive FPDs in comparison with the groups of resin bonded FPD and Two Key Bridge. Nevertheless, the maximum occlusal load of the restorative position, resistance to diverse restoration failure, amount of tooth reduction and patients' cooperation should be considered when they are applied in the clinic in order to choose an appropriate restoration for each patient.

Effect of Suprabulge Clasp and Infrabulge Clasp on the Mobility of Abutment Teeth for Distal Extension Removable Partial Dentures (유리단 국소의치에서 Suprabulge Clasp와 Infrabulge Clasp가 지대치 동요에 미치는 영향에 관한 연구)

  • Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.39-45
    • /
    • 1981
  • Distal-extension removable partial dentures have long been implicated in the increase in mobility and the destruction of the supporting structures of the primary abutment teeth. Various clasping systems have traditionally been used to retain distal extension removable partial dentures, and other designs have been proposed to minimize torquing forces on the abutment teeth. Most recent studies investigating the effects of removable partial dentures on abutment teeth have been performed in it laboratory setting. Results obtained from in vitro research have given dentists insight into removable partial denture design, but laboratory test model cannot be constructed that simulates actual functional or parafunctiona1 movements and forces. The purpose of this study was to clinically evaluate the degree of tooth mobility produced by two clasping systems (suprabulge type and infrabulge type) used for distal extension removable partial dentures. Akers clasp and R.P.I. system were selected for the evaluation, and four patients required a distal extension removable partial denture on the mandibular arch were selected for participation in the study. Two partial dentures were constructed in the same condition expect the design of clasp. All abutments in the study were mandibular first or second premolars. Measurements of mobility were made with a research tool designed by $M\"{u}hlemann$. This instrument, periodontometer, measures tooth mobility in the mouth by means of a dial gauge accurated to 0.01mm when the tooth is stressed with a force meter. Lingual and buccal deflection of abutment tooth was measured using buccal and lingual pressure. The amount of force applied was 500gm. Tooth mobility tests were made at four key stages; 1. Before insertion of the first removable partial denture, baseline mobility was establsihed. 2. After wearing of the first prosthesis, measurement was made at weekly intervals for 4 weeks. 3. The removable partial denture was then taken from the patient, and tooth mobility was measured again at weekly intervals until the patient's established baseline mobility had returned. 4. The second prosthesis of different clasp design was worn for a month and evaluated in the same manner as the first. The sequence of placement of clasping system was alternated between patients. The following results were obtained from this study; 1. The mobility of abutment tooth increased during the initial stage of wear and returned to baseline mobility after removal of removable partial dentures. 2. The mobility of abutment tooth showed no difference between Akers clasp and I-bar clasp during the 4-week test period. 3. All teeth tested showed greater mobility toward the buccal than the lingual direction.

  • PDF

Partial Key Exposure Attack on Unbalanced RSA with small CRT exponent (작은 CRT 지수를 사용한 RSA에서의 일부 키 노출 공격)

  • 이희정
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.14 no.5
    • /
    • pp.135-140
    • /
    • 2004
  • In Crypto 2002 May analyzed the relation between the size of two primes and private key in unbalanced RSA with small CRT exponent. Also in Crypto 2003 he showed that if $N^{1}$4/ amount of most significant bits(least significant bits) of $d_{p}$ is exposed in balanced RSA with CRT, N can be factored. To prove this he used Howgrave-Graham's Theorem. In this paper we show that if $N^{1}$4/ amount of $d_{p}$ , p is smaller than q, and bigger than $N^{0.382}$ to avoid May's attack, is exposed in unbalanced RSA with small CRT exponent, it is enough to expose $d_{p}$ . We use Coppersmith's theorem with unbalanced primes.

Marginal bone level change during sequential loading periods of partial edentulous rehabilitation using immediately loaded self-tapping implants: a 6.5-year retrospective study

  • Wang, Jing;Zhang, Zhengchuan;Deng, Feilong
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.133-142
    • /
    • 2022
  • PURPOSE. A large number of studies have suggested the practicability and predictability of immediate implant function, but few studies have reported marginal bone level changes during sequential loading periods. The purpose of this study was to evaluate the marginal bone remodeling of immediately loaded self-tapping implants both at each time point and during each loading period between two time points. MATERIALS AND METHODS. The patients included in this retrospective study were treated with immediately loaded NobelSpeedy Replace implants between August 2008 and July 2009. Differences in the marginal bone level (MBL) at each time point and the marginal bone level change (ΔMBL) between two time points were analyzed with Bonferroni correction (P < .05). RESULTS. Overall, 24 patients (mean age, 47.3 ± 12.8 years) with 42 immediately loaded implants and a median follow-up of 6.5 years (IQR, 67.8 months) were included. The cumulative survival rate after 10 - 12 years was 95.2%. Continuous but slow marginal bone loss was observed during long-term follow-up. MBL at both 7.5 years and 11 years was significantly lower than that at loading, 6 months, 2 years and 4 years (P < .05). No bone loss difference was found in any period before 4 years of follow up (P > .05). The loading period of 4 years to 7.5 years showed the largest ΔMBL compared to those of other time periods (P < .05). CONCLUSION. Slight bone loss occurred continuously, and more radical changes of marginal bone can be observed during the period of 4-7.5 years. Thus, long-term effective follow-up of immediately loaded implants is needed.

Partial dehulling increases the energy content and nutrient digestibility of barley in growing pigs

  • Wang, Hong Liang;Shi, Meng;Xu, Xiao;Pan, Long;Liu, Ling;Piao, Xiang Shu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.4
    • /
    • pp.562-568
    • /
    • 2017
  • Objective: The hull attached to the barley kernel can be mechanically removed thus reducing the fiber content of the barley. This experiment was carried out to evaluate the effects of partial dehulling on the nutrient digestibility as well as the digestible energy (DE) and metabolizable energy (ME) content of barley in pigs. Methods: Two hulled barley samples (high fiber barley [HF] and low fiber barley [LF]) with either high or low fiber contents were obtained from the Hubei and Jiangsu Provinces of China. A portion of the two barleys was mechanically dehulled (dehulled high fiber barley [DHF] and dehulled low fiber barley [DLF]). Thirty barrows (initial $BW=31.5{\pm}3.2kg$) were assigned to one of five diets in a randomized complete block design. The five diets consisted of 96.9% corn, HF, LF, DHF, or DLF supplemented with 3.1% minerals and vitamins. Each diet was fed to six barrows housed in individual metabolism crates for a 10-d acclimation period followed by a 5-day total but separate collection of feces and urine. Results: The daily loss of gross energy (GE) in feces was lower (p<0.01) for pigs fed DHF than for those fed HF. The daily N intake and fecal N loss were lowest (p<0.01) for pigs fed the corn diet. The DE and ME as well as the apparent total tract digestibility (ATTD) of dry matter, GE, organic matter, neutral detergent fiber (NDF) and acid detergent fiber (ADF) of DHF or DLF were higher (p<0.01) than the values in HF and LF, respectively while the values except the ATTD of NDF and ADF in DLF were higher (p<0.01) than the values in DHF and were comparable to corn. Conclusion: The DE and ME contents as well as the ATTD of nutrients in both DHF and DLF barley were improved compared with the HF and LF barley. Moreover, the nutritive value of DLF barley was comparable to the yellow-dent corn used in the study.

A Study of Partial Preview Control Method of ePUB-based eBook DRM (ePUB 기반 전자책 DRM의 부분열람 제어 방법에 관한 연구)

  • Kim, Eun-Bum;Kim, Kyung-Il;Kim, Tae-Hyun;Cho, Seong-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.249-256
    • /
    • 2012
  • ePUB is one of the most pervasive eBook formats since it was announced as a 2009 standard in IDPF(International Digital Publishing Forum). ePUB is compressed as a ZIP Archive format and structured as a standard format of OCF. Domestically and internationally, eBook services applying DRM into ePUB have currently been active, while it does not satisfy various needs from business because it does not support preview service which is due to the encryption of the whole ePUB as a single key. This study suggests a way to apply diverse business models by providing eBook content based on ePUB multiple key encryption method, not by encrypting it simply as a single key. The encryption method which applies a multiple key encryption method is suggested as a practically appliable form together with licence issuing and delivery method and decryption method in eBook readers. The multiple key encryption method suggested in this study will make it possible to support partial preview services of ePUB based eBook content. It will be applied to diverse service models and enhance the security level better then single key based encryption method.

Full-length cDNA, Expression Pattern and Association Analysis of the Porcine FHL3 Gene

  • Zuo, Bo;Xiong, YuanZhu;Yang, Hua;Wang, Jun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.10
    • /
    • pp.1473-1477
    • /
    • 2007
  • Four-and-a-half LIM-only protein 3 (FHL3) is a member of the LIM protein superfamily and can participate in mediating protein-protein interaction by binding one another through their LIM domains. In this study, the 5'- and 3'- cDNA ends were characterized by RACE (Rapid Amplification of the cDNA Ends) methodology in combination with in silico cloning based on the partial cDNA sequence obtained. Bioinformatics analysis showed FHL3 protein contained four LIM domains and four LIM zinc-binding domains. In silico mapping assigned this gene to the gene cluster MTF1-INPP5B-SF3A3-FHL3-CGI-94 on pig chromosome 6 where several QTL affecting intramuscular fat and eye muscle area had previously been identified. Transcription of the FHL3 gene was detected in spleen, liver, kidney, small intestine, skeletal muscle, fat and stomach, with the greatest expression in skeletal muscle. The A/G polymorphism in exon II was significantly associated with birth weight, average daily gain before weaning, drip loss rate, water holding capacity and intramuscular fat in a Landrace-derived pig population. Together, the present study provided the useful information for further studies to determine the roles of FHL3 gene in the regulation of skeletal muscle cell growth and differentiation in pigs.