• Title/Summary/Keyword: Partial Field

Search Result 932, Processing Time 0.034 seconds

PD Detection in Air by Capacitive Electric Field Sensor (전계센서의 원리를 이용한 공기중 부분방전신호 검출)

  • Lee, Y.H.;Lee, K.W.;Park, S.H.;Kang, S.H.;Shin, Y.S.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.900-903
    • /
    • 2002
  • Partial discharges(PD) in air, corona discharges, deteriorate the insulation strength. So, it is necessary to detect PD at an early stage before the system failure and extensive damage to the equipment. PD emit signals which can be detected by applying an capacitive electric field diagnosis. In this paper, We measured signals by capacitive electric field sensor and analyzed FFT from PD, and then compared conventional electric PD detecting method to capacitive electric field diagnosis by $\Psi-q-n$, $\Psi-v-n$, $\Psi-n$, $\Psi-q$ distributions.

  • PDF

EFFECT OF MAGNETIC FIELD ON LONGITUDINAL FLUID VELOCITY OF INCOMPRESSIBLE DUSTY FLUID

  • N. JAGANNADHAM;B.K. RATH;D.K. DASH
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.2
    • /
    • pp.401-411
    • /
    • 2023
  • The effects of longitudinal velocity dusty fluid flow in a weak magnetic field are investigated in this paper. An external uniform magnetic field parallel to the flow of dusty fluid influences the flow of dusty fluid. Besides that, the problem under investigation is completely defined in terms of identifying parameters such as longitudinal velocity (u), Hartmann number (M), dust particle interactions β, stock resistance γ, Reynolds number (Re) and magnetic Reynolds number (Rm). While using suitable transformations of resemblance, The governing partial differential equations are transformed into a system of ordinary differential equations. The Hankel Transformation is used to solve these equations numerically. The effects of representing parameters on the fluid phase and particle phase velocity flow are investigated in this analysis. The magnitude of the fluid particle is reduced significantly. The result indicates the magnitude of the particle reduced significantly. Although some of our numerical solutions agree with some of the available results in the literature review, other results differs because of the effect of the introduced magnetic field.

The effects of growth medium and partial shade on early growth of milkweed (Calotropis procera L.) under drought stress

  • Taghvaei, Mansour;Kordestani, Mojtaba Dolat
    • Journal of Ecology and Environment
    • /
    • v.35 no.4
    • /
    • pp.343-349
    • /
    • 2012
  • The use of growth medium is often recommended milkweed seedlings to grow and develop after emergence, and it is affected by growth medium and local habitat conditions. The effects of growth medium and partial shade on early growth of milkweed under drought stress (Calotropis procera L.) were studied in a field experiment. A split-split plot experimental design with three replications was carried out in the nursery. The main treatment plot was divided into two levels of shade; (no shading and partial shading). Sub treatment plot1 included growth medium at four levels (G1 = clay [suitable for milkweed growth], G2 = clay + sand, G3 = clay + perlite, G4 = clay + perlite + sand) and sub treatment plot2 included drought (irrigation intervals) at six levels (D1 = 2 [control], D2 = 4, D3 = 6, D4 = 8, D5 = 10, and D6 = 12 days per for three month). The results showed that drought stress significantly decreased emergence percentage, shoot length, shoot dry weight (SDW1), root dry weight (RDW), seedling dry weight (SDW2) and vigor index (VI). The use of growth medium increased all seedling characteristics. The G3 (clay + perlite) growth medium showed the highest performance, especially in terms of emergence percentage and seedling dry weight. Partial shade improved shoot length, shoot dry weight, and vigor index. Our results showed that the best treatment for high-vigor milkweed seedlings under drought stress was G3 (clay + perlite) growth medium and partial shade.

Partial Discharge Detection of High Voltage Switchgear Using a Ultra High Frequency Sensor

  • Shin, Jong-Yeol;Lee, Young-Sang;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.211-215
    • /
    • 2013
  • Partial discharge diagnosis techniques using ultra high frequencies do not affect load movement, because there is no interruption of power. Consequently, these techniques are popular among the prevention diagnosis methods. For the first time, this measurement technique has been applied to the GIS, and has been tested by applying an extra high voltage switchboard. This particular technique makes it easy to measure in the live state, and is not affected by the noise generated by analyzing the causes of faults ? thereby making risk analysis possible. It is reported that the analysis data and the evaluation of the risk level are improved, especially for poor location, and that the measurement of Ultra high frequency (UHF) partial discharge of the real live wire in industrial switchgear is spectacular. Partial discharge diagnosis techniques by using the Ultra High Frequency sensor have been recently highlighted, and it is verified by applying them to the GIS. This has become one of the new and various power equipment techniques. Diagnosis using a UHF sensor is easy to measure, and waveform analysis is already standardized, due to numerous past case experiments. This technique is currently active in research and development, and commercialization is becoming a reality. Another aspect of this technique is that it can determine the occurrences and types of partial discharge, by the application diagnosis for live wire of ultra high voltage switchgear. Measured data by using the UHF partial discharge techniques for ultra high voltage switchgear was obtained from 200 places in Gumi, Yeosu, Taiwan and China's semiconductor plants, and also the partial discharge signals at 15 other places were found. It was confirmed that the partial discharge signal was destroyed by improving the work of junction bolt tightening check, and the cable head reinforcement insulation at 8 places with a possibility for preventing the interruption of service. Also, it was confirmed that the UHF partial discharge measurement techniques are also a prevention diagnosis method in actual industrial sites. The measured field data and the usage of the research for risk assessment techniques of the live wire status of power equipment make a valuable database for future improvements.

Criterion to Choose Efficient Far-Field Approximation of Dyadic Green's Function for Impedance Plane like Ocean Surface (해수면 같은 임피던스 평면 위의 다이아딕 그린함수에 관한 효율적 원거리 근사공식 선택 기준)

  • Lee, Hyunsoo;Koh, Il-Suek;Yoon, Jong Suk;Kim, Tae Hyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.2
    • /
    • pp.147-154
    • /
    • 2017
  • The impedance approximation has been widely used to model an earth surface such as ocean surface. In calculation of the dyadic Green's function for the impedance half plane, Sommerfeld integral and its partial derivatives are required. It is known that two far-field approximation of the Sommerfeld integral can be represented in terms of Legendre or Laguerre polynomials. Hence, a criterion is required to choose one of two far-field approximations for a given application, which can be expressed in a complex plane of the surface impedance. Also, we approximate the required partial derivatives of Sommerfeld integral and numerically verify the accuracy of the approximation.

Partial transmission block production for real efficient method of block and MLC (Partial transmission block 제작 시 real block과 MLC를 이용한 방법 중 효율적인 방법에 대한 고찰)

  • Choi JiMin;Park JuYoung;Ju SangGyu;Ahn JongHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.19-24
    • /
    • 2004
  • Introduction : The Vaginal, the urethra, the vulva and anal cancer avoid the many dose to femur head and the additional treatment is necessary in inguinal LN. The partial transmission block to use inguinal LN addition there is to a method which it treats and produce partial transmission block a method and the MLC which to it analyzes. Material & Methode : The Inguinal the LN treatment patient partial transmission it used block and the MLC in the object and with solid water phantom with the patient it reappeared the same depth. In order to analyze the error of the junction the EDR2 (Extended dose range, the Kodak and the U.S) it used the Film and it got film scanner it got the beam profile. The partial transmission block and the MLC bias characteristic, accuracy and stability of production for, it shared at hour and comparison it analyzed. Result : The partial the transmission block compares in the MLC and the block production is difficult and production hour also above 1 hours. The custom the block the place where it revises the error of the junction is a difficult problem. If use of the MLC the fabrication will be break and only the periodical calibration of the MLC it will do and it will be able to use easily. Conclusion : The Inguinal there is to LN treatment and partial transmission block and the MLC there is efficiency of each one but there is a place where the junction of block for partial transmission block the production hour is caught long and it fixes and a point where the control of the block is difficult. like this problem it transfers with the MLC and if it treats, it means the effective treatment will be possible.

  • PDF

Model and Field Testing of a Heavy-Duty Gas Turbine Combustor

  • Ahn, Kook-Young;Kim, Han-Seok;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.9
    • /
    • pp.1319-1327
    • /
    • 2001
  • The results of stand and field testing of a combustion chamber for a heavy-duty 150 MW gas turbine are discussed. The model represented one of 14 identical segments of a tubular multican combustor constructed 1:1 scale. The model experiments were executed at a lower pressure than that in a real gas turbine. Combustion efficiency, pressure loss factor, pattern factor, liner wall temperature, flame radiation, fluctuating pressure and NOx emission were measured at partial and full loads for both model and on-site testing. The comparison of these items in the stand and field test results led to has the development of a method of calculation and the improvement of gas turbine combustors.

  • PDF

Design and Application of Electric Field Sensor for Measuring PD Signals in High Voltage Equipments (고전압설비에서 발생하는 부분방전 검출용 전계센서의 설계 및 특성 검토)

  • 이강원;강성화;임기조
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.431-435
    • /
    • 2003
  • It is very difficult and dangerous to measure PD(Partial Discharges) from high voltage equipments in outdoor situation. But that is very important thing for preventing them from more serious accident by defects made by insulating degradation. This paper provides useful method to detect PD signals easily without any dangerous situation. Electric field sensor by the principle of capacitor can detect PD signals without direct connection between sensor and high voltage equipment and has very wide frequency range suitable for noise rejection. Electric field sensor and related circuit for processing PD signal show good performance as a PD sensor when it is applied to simulated high power equipment generating PD pulses.

3X Serial GF(2$^m$) Multiplier on Polynomial Basis

  • Moon, San-Gook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.928-930
    • /
    • 2005
  • With an increasing importance of the information security issues, the efficienct calculation process in terms of finite field level is becoming more important in the Elliptic curve cryptosystems. Serial multiplication architectures are based on the Mastrovito's serial multiplier structure. In this paper, we manipulate the numerical expressions so that we could suggest a 3-times as fast as (3x) the Mastrovito's multiplier using the polynomial basis. The architecture was implemented with HDL, to be evaluated and verified with EDA tools. The implemented 3x GF (Galois Field) multiplier showed 3 times calculation speed as fast as the Mastrovito's, only with the additional partial-sum generation processing unit.

  • PDF