• Title/Summary/Keyword: Parallel Axis

Search Result 516, Processing Time 0.03 seconds

Compensating the Elliptical Trajectory of Elliptical Vibration Cutting Device (타원궤적 진동절삭기의 타원궤적 보정)

  • Loh, Byoung-Gook;Kim, Gi-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.789-795
    • /
    • 2011
  • In elliptical vibration cutting (EVC), cutting performance is largely affected by the shape of an elliptical path of the cutting tool. In this study, two parallel piezoelectric actuators were used to make an elliptical vibration cutting device. When harmonic voltages of $90^{\circ}$ out-of-phase are supplied to the EVC device, creation of an ideal elliptical trajectory whose major and minor axes are parallel to the cutting and thrust directions is anticipated from a kinematic analysis of the EVC device, however, the paths we experimentally observed showed significant distortions in its shape ranging from skew to excessive elongation of the major axis of the ellipse. To compensate distortions, an analytical model describing the elliptical path of the cutting tool was developed and verified with experimental results, and based on the analytical model, the distorted elliptical paths created at 100 Hz, 1 kHz, and 16 kHz were corrected for skew and elongation.

Electrode-Optic Characteristics of Fringe-field driven Twisted Nematic Mode using a Liquid Crystal with Negative Dielectric Anisotropy (유전율 이방성이 음인 액정을 이용한 fringe-field driven Twisted Nematic 모드의 전기광학 특성)

  • Song, I.S.;Shin, S.S.;Song, S.H.;Kim, H.Y.;Rhee, J.M.;Lee, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1054-1057
    • /
    • 2003
  • We have studied $90^{\circ}$ twisted nematic (TN) mode driven by fringe electric field, where two polarizers are parallel each other such that the cell shows a black state before a voltage is applied. According to the studies by computer simulation for a LC with negative dielectric anisotropy, the LC twists perpendicular to the horizontal field direction of fringe electric field and the degree of tilt angle is very low, when a voltage is applied. Therefore, the new device exhibits wide viewing angle characteristic due to in-plane switching and high transmittance since the LC director aligns parallel to the polarizer axis.

  • PDF

Design and Fabrication of Self-aligned Parallel-plate Type Micromirror Array (자기정렬에 의한 평판전극 마이크로미러 어린이의 설계와 제작)

  • Yoo, Byung-Wook;Kim, Min-Soo;Jin, Joo-Young;Jeon, Jin-A;Park, Jae-Hyong;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.150-151
    • /
    • 2007
  • We present an one-axis parallel-plate type of bulk micromachined torsional micromirror array with single crystalline silicon (SCS) fabricated on the glass substrate. Structurally, bottom electrodes (amophous silicon) in this mirror are DRIEed along the aluminum mirror patterns on SCS, which are self-aligned with mirror plates. Tracing the history of the micromirror study, we found that few papers have been published on research for uniform driving voltages based upon the tilting direction. If there is a slight misalignment during anodic bonding between top (mirror plate) and bottom electrodes, the non-uniformity of driving voltage will be led depending on two different tilting direction. This paper discusses how much the pull-in voltages can be different due to misalignment between two electrodes. Moreover, We achieve uniform pull-in voltage regardless of misalignments in photolithography and anodic-bonding between two individual layers.

  • PDF

The effect of upstream low-drag vortex generators on juncture flows

  • Younis, Md.Y.;Zhang, Hua;Hu, Bo;Uddin, Emad;Aslam, Jawad
    • Wind and Structures
    • /
    • v.28 no.6
    • /
    • pp.355-367
    • /
    • 2019
  • Control of horseshoe vortex in the circular cylinder-plate juncture using vortex generator (VG) was studied at $Re_D$(where D is the diameter of the cylinder) = $2.05{\times}10^5$. Impact of a number of parameters e.g., the shape of the VG's, number of VG pairs (n), spacing between the VG and the cylinder leading edge (L), lateral gap between the trailing edges of a VG pair (g), streamwise gap between two VG pairs ($S_{VG}$) and the spacing between the two VG's in parallel arrangement ($Z_{VG}$) etc. were investigated on the horseshoe vortex control. The study is conducted using surface oil flow visualization and surface pressure measurements in low speed wind tunnel. It is observed that all the parameters studied have significant control effect, either by reduction in separation region or by lowering the adverse pressure along the symmetric axis upstream of the juncture.

A Monte Carlo Study of the Diffusion Process of Thomson-Scattered Line Radiation in Phase Space

  • Hyeon Yong Choe;Hee-Won Lee
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.1
    • /
    • pp.23-33
    • /
    • 2023
  • We investigate the diffusion process of Thomson-scattered line photons in both real space and frequency space through a Monte Carlo approach. The emission source is assumed to be monochromatic and point-like embedded at the center of a free electron region in the form of a sphere and a slab. In the case of a spherical region, the line profiles emergent at a location of Thomson optical depth τTh from the source exhibit the full width of the half maximum σλ ≃ τ1.5Th. In the slab case, we focus on the polarization behavior where the polarization direction flips from the normal direction of the slab to the parallel as the slab optical depth τTh increases from τTh ≪ 1 to τTh ≫ 1. We propose that the polarization flip to the parallel direction to the slab surface in optically thick slabs is attributed to the robustness of the Stokes parameter Q along the vertical axis with respect to the observer's line of sight whereas randomization dominates the remaining region as τTh increases. A brief discussion on the importance of our study is presented.

Investigation of Fracture Propagation in Cement by Hydraulic Fracturing Under the Tri-axial Stress Condition (시멘트 시료에 대한 삼축압축 환경에서의 수압파쇄시험 연구)

  • Riu, Hee-Sung;Jang, Hyun-Sic;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.233-244
    • /
    • 2017
  • We conducted hydraulic fracturing experiments on cement samples to investigate the dependency of fracture propagation on the viscosity of injection fluid and the in situ stress state. Ten cubic samples (20 cm side length) were produced using cement that was cured in water for more than one month. Samples were placed in a tri-axial compression apparatus with three independent principal stresses. An injection hole was drilled and the sample was hydraulically fractured under a constant injection rate. We measured injection pressures and acoustic emissions (AE) during the experiments, and investigated the fracture patterns produced by hydraulic fracturing. Breakdown pressures increased exponentially with increasing viscosity of the injection fluid. Fracture patterns were dependent on differential stress (i.e., the difference between the major and minor principal stresses). At low differential stress, multiple fractures oriented sub-parallel to the major principal stress axis propagated from the injection hole, and in some samples the fracture orientation changed during propagation. However, at high differential stress, a single fracture propagated parallel to the major principal stress axis. AE results show similar patterns. At low differential stress, AE source locations were more widespread than at high differential stress, consistent with the fracture pattern results. Our study suggests that hydraulic fracturing during shale gas extraction should be performed parallel to the orientation of minimum differential stress.

A study on anisotropic characteristics of axial strengths in $\alpha$-quartz by using molecular dynamics simulation and uniaxial compression test (분자동력 학 시뮬레이션과 일축압축강도시험을 이용한 $\alpha$-quartz의 결정축에 따른 강도이방성 검토)

  • ;;市川康明;河村雄行
    • Tunnel and Underground Space
    • /
    • v.10 no.1
    • /
    • pp.70-79
    • /
    • 2000
  • We carried out NPT-ensemble (constant-number of particles, pressure, and temperature) Molecular Dynamics (MD) simulations for measuring strength anisotropy under uniaxial compressive stress rotated to the crystallographic axes in $\alpha$-quartz. Uniaxial compressive strengths of a single quartz crystal were measured in directions of the a- and c-axis. Measured uniaxial strength of a single quartz crystal was higher in the direction parallel to the c-axis than that measured in the direction normal to the c-axis. However the reverse was found in calculated uniaxial strengths by MD simulation. The contradictive result of strengths was observed in both cases but was found to be different in origin. Strength anisotropy of defectless $\alpha$-quartz crystal in MD simulation is basically caused by structural difference of quartz. By contrast, anisotropy of measured strength in the uniaxial compression test is related to oriented micro-defects developed during crystal growth.

  • PDF

Effects of Seed Layers on Formation of Barium Ferrite Thin Films and Their Magnetic Properties (씨앗층이 바륨훼라이트 박막의 형성과 자기적 성질에 미치는 영향)

  • 나종갑;이택동;박순자
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.1
    • /
    • pp.22-28
    • /
    • 1992
  • Barium ferrite thin films were reactively deposited with Fe and BaO composite targets by a facing tergects sputtering unit. When thermally oxidized silicon wafers were used as substrates, minimum substrate heating of $750^{\circ}C$ was necessary for the perfect c-axis alignment in barium ferrite films. To lower the critical substrate temperature for the good c-axis alignment, such seed layers as ZnO, ${\alpha}-Fe_{2}O_{3}$ and ${\gamma}-Fe_{2}O_{3}$ were tested. The excellent c-axis algnment of BaM was obtained at a substrate temperature of $600^{\circ}C$ on ZnO seed layer whose (002) plane was parallel to the substrate surface. The magnetic properties of the BaM film showed saturation magnetization of 295 emu/cc, perpendicular coercivity of 1.7 kOe and squareness of 0.75. Optimum deposition rate of $230\;{\AA}/min$ was obtained with the composite target and this was 5 to 20 times higher than those of other investigators with oxide targets.

  • PDF

Usefulness of lateral cephalometric radiography for successful blind nasal intubation: a prospective study

  • Ito, Kana;Kamura, Ayaka;Koshika, Kyotaro;Handa, Toshiyuki;Matsuura, Nobuyuki;Ichinohe, Tatsuya
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.6
    • /
    • pp.427-435
    • /
    • 2022
  • Background: This study aimed to investigate the relationship between pharyngeal morphology and the success or failure of blind nasotracheal intubation using standard lateral cephalometric radiography and to analyze the measurement items affecting the difficulty of blind nasotracheal intubation. Methods: Assuming a line perpendicular to the Frankfort horizontal (FH) plane, the reference point (O) was selected 1 cm above the posterior-most end of the hard palate. A line passing through the reference point and parallel to the FH plane is defined as the X-axis, and a line passing through the reference point and perpendicular to the X-axis is defined as the Y-axis. The shortest length between the tip of the uvula and posterior pharyngeal wall (AW), shortest length between the base of the tongue and posterior pharyngeal wall (BW), and width of the glottis (CW) were measured. The midpoints of the lines representing each width are defined as points A, B, and C, and the X and Y coordinates of each point are obtained (AX, BX, CX, AY, BY, and CY). For each measurement, a t-test was performed to compare the tracheal intubation success and failure groups. A binomial logistic regression analysis was performed using clinically relevant items. Results: The items significantly affecting the success rate of blind nasotracheal intubation included the difference in X coordinates at points A and C (Odds ratio, 0.714; P-value, 0.024) and the ∠ABC (Odds ratio, 1.178; P-value, 0.016). Conclusion: Using binomial logistic regression analysis, we observed statistically significant differences in AX-CX and ∠ABC between the success group and the failure group.

Capability of Turbulence Modeling Schemes on Estimating the Film Cooling at Parallel Wall Jet-Nozzle Configuration (평행 벽 제트-노즐 형상에서 난류모델별 막냉각 예측 능력)

  • Lee, Jun;Kim, Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.1
    • /
    • pp.10-18
    • /
    • 2009
  • Numerical simulation has been performed in this study to investigate the capabilities of turbulence modeling schemes on estimating the film cooling at a referenced parallel wall jet-nozzle configuration. Also a additional simulation has been performed for film cooling under 2-dimensional axis symmetry conditions at a parallel wall jet-nozzle configuration. It was concluded that the best turbulence model is the standard $k-{\epsilon}$ model with enhanced wall functions. Also a additional simulation showed the film cooling characteristics that are resonable physically.