• 제목/요약/키워드: Packed-capillary

검색결과 35건 처리시간 0.019초

Preparation of Three Different Style Packed Capillary Frits

  • Ryoo, Jae-Jeong;Song, Young-Ae;Lee, Kwang-Pill;Park, Ji-Yeon;Choi, Seong-Ho;Hyun, Myung-Ho;Ohta, Kazutoku;Fujimoto, Chuzo;Jin, Ji-Ye;Takeuchi, Toyohide;Lee, Jung-Whan
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권4호
    • /
    • pp.524-528
    • /
    • 2006
  • Three different style capillary columns, a packed capillary with temporary quartz wool frit, a packed capillary with immobilized frit, and an immobilized packed-capillary, were easily prepared with a commercially available (S)-N-(3,5-dinitro-benzoyl)leucine-N-phenyl-N-alkylamide derived chiral stationary phase. Liquid chromatographic chiral separations of some racemic amino acid derivatives on these columns were performed and the results were compared to each other. The packed capillary with immobilized frit showed some merits in chiral chromatography.

식초의 에탄올 및 초산 함량의 동시분석 (Simultaneous Gas Chromatographic Analysis of Ethanol and Acetic Acid in Vinegar)

  • 윤희남
    • 한국식품과학회지
    • /
    • 제30권6호
    • /
    • pp.1247-1251
    • /
    • 1998
  • 식초의 에탄올과 초산을 동시에 분석하고자 packed column으로 gas chromatographic analysis을 모색하였다. Tenax-GC를 충진물로 사용하여 $2\;m{\times}2\;mm$의 stainless steel column을 제조하고 식초를 여과하여 column에 직접 주입한 결과 내부 표준 물질로 사용한 isopropyl alcohol과 에탄올, 초산이 20분 이내에서 완전히 분리되었으며 정확도가 매우 높은 것으로(P<0.05)나타났다. 19종의 식초를 이용하여 적정방법으로 산도를, packed column GSC로 에탄올과 초산을, HPLC로 초산을, capillary column GLC로 에탄올과 초산을 각각 분석하여 분석치들을 상호 비교하였다.

  • PDF

충전컬럼 및 모세관컬럼 가스크로마토그라프에 의한 마요네즈 중의 스테롤 분석연구 (Studies on Analysis of Sterols in Mayonnaise by GLC with Packed and Capillary Column)

  • 김현위;정소영;정창기;윤형식;박기문;안평욱;최춘언
    • 한국식품과학회지
    • /
    • 제24권1호
    • /
    • pp.82-85
    • /
    • 1992
  • 가스크로마토그라프법으로 마요네즈 중의 스테롤을 정량하는데 있어서 충전컬럼과 모세관 컬럼을 사용하여 비교 연구하였다. 두 컬럼의 경우 4종의 스테롤(cholesterol, campesterol, stigmasterol, ${\beta}-sitosterol$)이 모두 뚜렷히 분리되었으나 모세관 컬럼이 신속성, 재현성, 분리능 면에서 우수하였다. 한편, 제품에 적용하여 분석한 결과, 측정된 cholesterol 함량으로부터 추정한 시판 마요네즈 난황사용량은 충전컬럼의 경우 $2.69{\sim}7.11%$, 모세관 컬럼의 경우 $2.42{\sim}6.08%$ 범위이었으며, 스테롤 조성으로부터 마요네즈 제조에 사용된 식용유는 대두유 및 면실유임을 알 수 있었다.

  • PDF

A Capillary Electrochromatographic Microchip Packed with Self-Assembly Colloidal Carboxylic Silica Beads

  • Jeon, In-Sun;Kim, Shin-Seon;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권4호
    • /
    • pp.1135-1140
    • /
    • 2012
  • An electrochromatographic microchip with carboxyl-group-derivatized mono-disperse silica packing was prepared from the corresponding colloidal silica solution by utilizing capillary action and self-assembly behavior. The silica beads in water were primed by the capillary action toward the ends of cross-patterned microchannel on a cyclic olefinic copolymer (COC) substrate. Slow evaporation of water at the front of packing promoted the self-assembled packing of the beads. After thermally binding a cover plate on the chip substrate, reservoirs for sample solutions were fabricated at the ends of the microchannel. The packing at the entrances of the microchannel was silver coated to fix utilizing an electroless silver-plating technique to prevent the erosion of the packed structure caused by the sudden switching of a high voltage DC power source. The electrochromatographic behavior of the microchip was explored and compared to that of the microchip with bare silica packing in basic borate buffer. Electrophoretic migration of Rhodamine B was dominant in the microchip with the carboxyl-derivatized silica packing that resulted in a migration approximated twice as fast, while the reversible adsorption was dominant in the bare silica-packed microchip. Not only the faster migration rates of the negatively charged FITC-derivatives of amino acids but also the different migration due to the charge interaction at the packing surface were observed. The electrochromatographic characteristics were studied in detail and compared with those of the bare silica packed microchip in terms of the packing material, the separation potential, pH of the running buffer, and also the separation channel length.

A Study on Capillary Column Ion Chromatography

  • 김호현;표동진
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2001년도 정기총회 및 봄 학술발표회 초록집
    • /
    • pp.115-116
    • /
    • 2001
  • 본 연구에서는 이온 크로마토그래피로 환경오염물질들을 분석하고자 할때의 단전들을 해소하기 위하여 모세관 컬럼 이온 크로마토그래피를 개발하였다. 모세관 컬럼은 두가지 형태로 개발하였는데 하나는 packed capillary 컬럼이며 다른하나는 open tubular capillary 컬럼이다. 또한 위와 같이 모세관 컬럼을 개발하여 사용하게됨을써, 부수적으로 펌프, 시료주입기, 억압장치 그리고 전도도 셀 등을 모두 적은 부피를 다룰 수 있는 구조로 바꾸어 주었다. 따라서 본 연구의 결과로 미량환경오염 물질의 분석에 모세관 컬럼 이온크로마토그래피를 이용할 수 있는 가능성을 확인할 수 있었고, 나아가 이온 크로마토그래피의 소형화로 현장에서 직접 분리, 분석을 할 수 있으리라 기대된다.

  • PDF

Capillary Hemangioma of the Thoracic Spinal Cord

  • Chung, Sung-Kyun;Nam, Taek-Kyun;Park, Seung-Won;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권3호
    • /
    • pp.272-275
    • /
    • 2010
  • Capillary hemangiomas are common soft tissue tumors on the skin or mucosa of the head and neck in the early childhood, but very rare in the neuraxis. A 47-year-old man presented with one month history of back pain on the lower thoracic area, radiating pain to both legs, and hypesthesia below 17 dermatome. Thoracic spine MRI showed $1{\times}1.3{\times}1.5\;cm$, well-defined intradural mass at T6-7 disc space level, which showed isointensity to spinal cord on T1, heterogeneous isointensity on T2-weighted images, and homogeneous strong enhancement. The patient underwent T6-7 total laminotomy, complete tumor removal and laminoplasty. Histologically, the mass showed a capsulated nodular lesion composed of capillary-sized vascular channels, which were tightly packed into nodules separated by fibrous septa. These features were consistent with capillary hemangioma.

냉장고 냉매소음 저감을 위한 단열 발포재의 진동 전달특성 분석 (Analysis of the Vibration Transmitting Characteristics of the Insulation-foam for Reducing Refrigerant-induced Noise of a Refrigerator)

  • 한형석;김민성;정의봉;서민영;이수영
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.45-50
    • /
    • 2010
  • In the refrigerator, the two-phase refrigerant-induced noise of the capillary tube in an evaporator-inlet pipe has been a great concern. The capillary tube is usually covered with insulation-foam packed in the space between inner and outer cabinets without any vibration isolation. Therefore, the refrigerant-induced vibration of the capillary tube can be easily transferred to the outer cabinet, which may increase the radiated noise. In this paper, the characteristics of transferred vibration through the insulation-foam are investigated experimentally by using the refrigerantsupplying equipment. The frequency characteristics, such as dynamic Young's modulus and loss factor, of the insulation-foam are also discussed.

On-Channel Micro-Solid Phase Extraction Bed Based on 1-Dodecanethiol Self-Assembly on Gold-Deposited Colloidal Silica Packing on a Capillary Electrochromatographic Microchip

  • Park, Jongman;Kim, Shinseon
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권1호
    • /
    • pp.45-50
    • /
    • 2014
  • A fully packed capillary electrochromatographic (CEC) microchip with an on-column micro-solid phase extraction (SPE) bed for the preconcentration and separation of organic analytes was prepared. A linear microchannel with monodisperse colloidal silica packing was formed on a cyclic olefinic copolymer microchip with two reservoirs on both ends. Silver-cemented silica packing frit structure was formed at the entrance of the microchannel by electroless plating treatment as a base layer. A gold coating was formed on it by reducing $Au^{3+}$ to gold with hydroxylamine. Finally micro-SPE bed was formed by self-assembly adsorption of 1-dodecanethiol on it. Micro-SPE beds were about 100-150 ${\mu}m$ long. Approximately $10^3$ fold sensitivity enhancements for Sulforhodamine B, and Fluorescein in nM concentration levels were possible with 80 s preconcentration. Basic extraction characteristics were studied.

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • 제2권3호
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.

Development of Ultra-High Pressure Capillary Reverse-Phase Liquid Chromatography/Tandem Mass Spectrometry for High-Sensitive and High-Throughput Proteomics

  • Kim, Min-Sik;Choie, Woo-Suk;Shin, Yong-Seung;Yu, Myeong-Hee;Lee, Sang-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권12호
    • /
    • pp.1833-1839
    • /
    • 2004
  • Recently mass spectrometry and separation methods such as liquid chromatography have become major tools in the field of proteomics. In this report, we describe in detail our efforts to develop ultra-high pressure capillary reverse-phase liquid chromatography (cRPLC) and its online coupling to a mass spectrometer by a nanoelectrospray (nanoESI) interface. The RPLC system is constructed in house to deliver LC solvents at the pressure up to 20,000 psig, which is four times higher than conventional RPLC systems. The high operation pressure allows the efficient use of packed micro-capillary columns (50, 75 and 150 ${\mu}$m i.d., up to 1.5 m long). We will discuss the effect of column diameter on the sensitivity of cRPLC/MS/MS experiments and the utility of the developed technique for proteome analysis by its application in the analysis of proteome samples having different levels of complexity.