DOI QR코드

DOI QR Code

냉장고 냉매소음 저감을 위한 단열 발포재의 진동 전달특성 분석

Analysis of the Vibration Transmitting Characteristics of the Insulation-foam for Reducing Refrigerant-induced Noise of a Refrigerator

  • 발행 : 2010.01.20

초록

In the refrigerator, the two-phase refrigerant-induced noise of the capillary tube in an evaporator-inlet pipe has been a great concern. The capillary tube is usually covered with insulation-foam packed in the space between inner and outer cabinets without any vibration isolation. Therefore, the refrigerant-induced vibration of the capillary tube can be easily transferred to the outer cabinet, which may increase the radiated noise. In this paper, the characteristics of transferred vibration through the insulation-foam are investigated experimentally by using the refrigerantsupplying equipment. The frequency characteristics, such as dynamic Young's modulus and loss factor, of the insulation-foam are also discussed.

키워드

참고문헌

  1. Han, H. S., Jeong, W. B., Aoyama, S. and Mo, J. Y., 2008, “Experimental Analysis for Reducing Refrigerant-induced Noise of 4-way Cassette Type Air Conditioner,” J. of JMST, Vol. 23, No. 5, pp. 1456-1467. https://doi.org/10.1007/s12206-008-1128-8
  2. Umeda, T, 1993, “Reduction of Noise Caused by Gas-liquid Two-phase Refrigerant Flow Through an Expansion Valve,” J. of JSME, Vol. 59, No. 557, pp. 243-248. https://doi.org/10.1299/kikaib.59.243
  3. Hirakuni, S, 2004, “Noise Reduction Technology Caused by Refrigerant Two-phase Flow for Room Air-conditioner,” Japanese J. Multiphase Flow, Vol. 18, No. 1, pp. 23-30.
  4. Kim, M. S., Jeong, W. B., Han, H. S. and Kim, T. H., 2009, “Reduction of Refrigerant-induced Noise of the Refrigerator by Modification of the Evaporator Inlet Pipe,” Transactions of the Korean Society for Noise and Vibrations Engineering, Vol. 19, No. 10, pp. 1012-1020. https://doi.org/10.5050/KSNVN.2009.19.10.1012
  5. Han, H. S., Aoyama, S., Mo, J. Y., Lee, J. K., Song, Y. J., 2006, “Analyzing for Refrigerant Induced Noise for Split Type Air Conditioner Indoor Unit,” Transactions of the Korean Society for Noise and Vibrations Engineering, Vol. 16, No. 3, pp. 240-246. https://doi.org/10.5050/KSNVN.2006.16.3.240
  6. Snowdon, J. C., 1979, “Vibration Isolation: Use and Characterization,” U.S Department of Commerce.
  7. KS M 6604, 2006, “Testing Method for Rubber Vibration Isolator,” Korean Standards Association.