• 제목/요약/키워드: PV.1

검색결과 1,004건 처리시간 0.031초

전력산업용 PV System의 각 용량별 설계 파라미터 도출에 관한 연구 (Study on the Elicitation of Parameter in Designing each Capacity of PV System for Power Industry)

  • 김병만;이길송;양연원;신현우;김의환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.78.1-78.1
    • /
    • 2010
  • Recently, as much supplied with new-renewable energy, as much invested in PV system. PV system consists of PV module, PCS and Monitering system, and also could be classified into the type and the capacity by installation method and cost etc. When various systems are installed in the field, it is needed to research for applying in the field and establish infrastructure in order to ensure stable efficiency and reliability. In this study, as the basic design of the demonstration test facility, it is designed the basic PV systems for each capacity to test each PCS. In addition, It is drew the climatic conditions such as insolation, temperature and the design parameters such as installation angle, shades for the local demonstration project and expected the generation of each PV system.

  • PDF

기상조건, 방위각 및 경사각에 따른 태양광발전시스템 출력 분석 (PV System Output Analysis Based on Weather Conditions, Azimuth, and Tilt Angle)

  • 이상혁;권오현;이경수
    • Current Photovoltaic Research
    • /
    • 제5권1호
    • /
    • pp.38-42
    • /
    • 2017
  • PV system output is determined according to the weather conditions, the azimuth and tilt angle. Weather conditions are changing every moment and it seems to vary according to the daily, monthly, and annual basis. The azimuth and tilt angle is decided along the site conditions for the PV system installation. This paper analyzed the PV system output through the changing the weather conditions, the azimuth, and tilt angle. We compared the TMY data and analysis of the two major weather institutes which are KMA and METEONORM. PV system output trend were analyzed by changing the azimuth and tilt angle. We used simulation tool, which is named PVsyst for the entire PV system analysis.

오일레스 복합계 베어링재의 최대허용 PV값 측정에 관한 실험적 고찰 (An Experimental Analysis on the Maximum Allowable PV Value of Oilless Composite Bearing Materials)

  • 공호성;윤의성;전기수;송광호
    • Tribology and Lubricants
    • /
    • 제11권1호
    • /
    • pp.27-36
    • /
    • 1995
  • Maximum allowable PV values of oilless composite bearing materials (70% epoxy-resin/30% Graphite) were measured and compared at various types of test rigs that have different contact geometry and the operating conditions. Test results showed that material failure was mainly characterized by the sharp increase in both coefficient of friction and surface temperature, and different PV values were measured under different Contact geometry. The discrepancy in measurement of PV values was analyzed in the light of theoretical frictional heating analysis. Results show that surface temperature rise depends on its contact geometry, and PV values could be overestimated in the testing conditions of high sliding velocity. Test data of different contact geometry were normalized by using a normalized contact pressure and sliding velocity; it showed a good correlation. This work suggests that normalized PV values could be more effective in evaluating bearing materials than conventional PV values for a design parameter of journal bearings.

호기성 Bioreactor 매립지에 있어서 공기주입량이 선별토사의 안정화에 미치는 영향 (The Effect of Air Injection Quantity on Stabilization of Screened Soil in Aerobic Bioreactor Landfill)

  • 박진규;이남훈;김낙주
    • 유기물자원화
    • /
    • 제12권1호
    • /
    • pp.104-109
    • /
    • 2004
  • 본 연구는 공기주입에 의한 고형 폐기물의 빠른 안정화를 달성할 수 있는 매립지의 호기성 공정을 평가하는 것을 목표로 하였다. 실험은 매립지에서 최적의 공기주입방법을 평가하기 위해 선별토사를 충전한 4개의 모의 매립조(혐기성, 1PV(pore volume/day)공기주입, 5PV 공기주입, 10PV 공기주입)를 운영하였다. 선별토사를 충전한 bioreactor를 호기성으로 운전한 경우에 공기를 주입하지 않은 bioreactor에 비해 유기물 분해가 뛰어난 것으로 나타났다. 매립가스의 발생량 및 조성변화와 soil respiration test 결과로부터 5 PV/day으로 공기를 주입한 bioreactor가 유기물 분해율이 가장 높은 것으로 나타났다.

  • PDF

Matlab을 이용한 PV모듈의 I-V시뮬레이션 관한 연구 (Study on I-V simulation for PV module with matlab)

  • 홍종경;정태희;강기환;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제29권4호
    • /
    • pp.1-6
    • /
    • 2009
  • This paper estimates numerically cells the electrical characteristics of the PV module with environmental changes such as shunt resistance, series resistance, temperature, irradiance. Series resistance $R_s$ including diode characteristic resistance $r_d$ is derived from the p-n junction diode model. I-V characteristics of this model with series resistance $R_s$ are simulated on Matlab. Finally, theoretical I-V characteristics are compared with those of solar simulator. Those results agreed well within the manufacturer's maximum error range 3%

Monitoring and Analysis of 3kW Grid-Connected PV System for Performance Evaluation

  • So Jung-Hun;Jung Young-Seok;Yu Gwon-Jong;Choi Ju-Yeop;Choi Jae-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.57-62
    • /
    • 2005
  • Grid-connected photovoltaic (PV) systems were installed and monitored at the field demonstration test center (FDTC) in Korea in October 2002. Before long-term field testing of installed PV systems, the performances of PV components were evaluated and compared through short-term performance tests of each of the PV system components such as power conditioning system and PV module under standard test conditions. A data acquisition system has been constructed for measuring and analyzing the performance of PV systems to observe the overall effect of environmental conditions on their operation characteristics. Performances of PV systems have been evaluated and analyzed not only for component perspective (PV array, power conditioning unit) but also for global perspective (system efficiency, capacity factor, electrical power energy) by review of the field test and loss factors of the systems. These results indicate that it is highly imperative to develop an optimum design technology of grid connected PV systems. The objective of this paper is not only to evaluate and analyze the performance of domestic PV systems application through long-term field testing at FDTC but also to develop evaluation, analysis and optimum technology for long-term stability and reliability of grid-connected PV systems in Korea.

대용량 태양광발전이 연계된 배전계통의 수용가 전압 특성해석에 관한 연구 (A Study on the Customer Voltage Characteristic of Distribution System with Large Scale PV)

  • 김병기;유경상;김찬혁;노대석
    • 전기학회논문지
    • /
    • 제62권1호
    • /
    • pp.29-36
    • /
    • 2013
  • This paper deals with the analysis of the customer voltage characteristic in distribution system interconnected with large scale PV system. There would be many power quality issues which are caused by reverse power flow of PV system interconnected with distribution system. In order to analyze the effect of PV system on the customer voltage, detailed modeling method of distribution system and modified modelling method of PV system are proposed using PSCAD/EMTDC in this paper. So far, less than dozens KW of PV system can be simulated with the existing modelling method. Therefore, a new modeling method which can simulate the large scale PV system is proposed by considering the relationship equation on the phase and voltage in the current control algorithm. From the simulation result of proposed modelling method, it is confirmed that an optimal operation method in distribution system is suggested by analyzing the effect of PV system on customer voltage.

PV cell modeling의 수학적 고찰 (Mathematical Consideration on PV Cell Modeling)

  • 박현아;김효성
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.51-56
    • /
    • 2014
  • PV cell modeling is necessary both for software and hardware simulators in analyzing and testing the performance of PV generation systems. Unique I-V curve of a PV cell identifies its own characteristics by electrical equivalent model that is composed of diode constants ($I_o$, $v_t$), photo-generated current ($I_{ph}$), series resistance ($R_s$), and shunt resistance ($R_{sh}$). Photo-generated current can be easily estimated since it is proportional to irradiation level. However, other electrical parameters should be solved from the manufacturer's data sheet that is consisted with three remarkable operating points such as open circuit voltage ($V_{oc}$), short circuit current ($I_{sc}$), and maximum power voltage/current ($V_{MPP}/I_{MPP}$). This paper explains and analyzes mathematical process of a novel PV cell modeling algorithm that was proposed by the authors with the name of "K-algorithm".

우리나라에서 분리한 참다래 궤양병균 Pseudomonas syringae pv. actinidiae 균주들의 Biovar (Biovars of Pseudomonas syringae pv. actinidiae Strains, the Causal Agent of Bacterial Canker of Kiwifruit, Isolated in Korea)

  • 이영선;김진;김경희;최으뜸;고영진;정재성
    • 식물병연구
    • /
    • 제23권1호
    • /
    • pp.35-41
    • /
    • 2017
  • Pseudomonas syringae pv. actinidiae는 참다래에 궤양병을 일으키는 원인세균이다. 이 병원균 집단은 분자적 특성에 따라 biovar 1, 2, 3로 나누어진다. 본 연구에서는 1997년부터 우리나라에서 분리되어 순천대학교 생물학과에 보관 중인 P. syringae pv. actinidiae 균주들의 biovar를 기존에 발표된 biovar에 특이적인 PCR primers를 사용하여 동정하였다. 전체 682개 균주 중 biovar 2에 속한 균주가 288개, biovar 3에 속한 균주가 394개였다. 그러나 우리나라에서 분리된 균주 중 biovar 1에 속하는 균주는 없었다. Biovar 3 균주에 의한 궤양병의 갑작스러운 발생과 확산은 이 균주가 빠른 전파력을 가지고 있음을 말해준다.

Hierarchical Mobile IP에서 라우터기반 바인딩 업데이트 방법을 이용한 네트워크 이동성 지원 (Network Mobility Support Using Router-based Binding Update Scheme in Hierarchical Mobile IP)

  • 김주현;이경근
    • 한국통신학회논문지
    • /
    • 제34권7B호
    • /
    • pp.668-676
    • /
    • 2009
  • IETF(Internet Engineering Task Force)에서 IP망에서 이동성 지원을 위해 Mobile 1Pv6(M1Pv6)를 시작으로 Hierarchical MlPv6(HMIPv6) 등을 제안하였지만, 이러한 클라이언트 기반 이동성 지원 연구들은 이동성 지원 메시지 전송을 위한 무선자원 낭비와 긴 핸드오버 지연 등을 야기함으로 인해 주목을 받지 못하고 있다. 본 논문에서는 기존 클라이언트 기반 이동성 지원 기술의 문제점 해결을 위해 Router-based Binding Update(RBU) 방법을 제안한다. RBU 방법은 기존 HMIPv6에서 단말기에 추가 구현없이 Neighbor Discovery 프로토콜을 통해 라우터가 Mobility Anchor Point(MAP)에 위치등록을 한다. 이와 같은 방법을 통하여 RBU 방법은 부분적인 네트워크 기반 이동성을 지원하며 HMIPv6에 비해 핸드오버 시간을 줄일 수 있도록 설계 되었다. 제안방안의 성능검증을 위해 기존 HMlPv6와 비교 분석하였다. 그 결과 RBU 방법이 HMlPv6에 비해 매크로 도메인 핸드오버에 대해 지연시간이 최대 약 15% 줄어들며 특히 무선링크 지연이 큰 경우 좋은 성능을 보인다.