• Title/Summary/Keyword: PV(photovoltaic) 어레이

Search Result 43, Processing Time 0.023 seconds

A Study on the Optimal Design of Large-scale Photovoltaic Array (대용량 PV 어레이의 최적설계에 관한 연구)

  • Hwang, In-Ho;Kim, Eui-Hwan;Ahn, Kyo-Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.8-14
    • /
    • 2011
  • Recently, a number of large-scale photovoltaic(PV) power generation system has been installed all over the world. Thus, in order to improve the system efficiency, the optimal design of the large-scale PV systems has become an important issue. DC cable loss of PV array is one of the design factors related to the system efficiency. This paper introduces the array design method of a 500kW Photovoltaic power plant. Three types of the PV array are suggested. Also, string cables, sub-array cables and array cables are designed within 1% of voltage drop in the line, and the DC cable losses are analyzed. The results of this paper show that the DC cable loss of large-scale PV array can be reduced by adopting a proper sub-array design method.

Development of PSCAD User-defined Model for the Simulation of a PV Array (PV 어레이의 계통연계 모의를 위한 PSCAD 사용자 정의 모델 개발)

  • Ahn, Seon-Ju;Choi, Joon-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.134-139
    • /
    • 2011
  • Since large and small scale photovoltaic(PV) systems have been commercialized in many countries, it is necessary to assess the effects of PV systems on the electric power system. For this, the development of accurate simulation model of PV arrays is very important. PSCAD/EMTDC, a widely used simulation tool for analyzing the transient behavior of electrical apparatus and networks, does not have a standard model of a PV array. Therefore in order to simulate the PV array, users have to develop their own simulation model. However, the block-diagram-based model is very complicated, and it is hard to modify the model parameters. In this study, we develop the user-defined model of a PV array by using the Design Editor, which is provided by PSCAD program. The mathematical model of a PV array and the method to determine the parameters of nonlinear I-V equation are implemented in a Fortran code. The graphical user interface provides the users with easy and simple way to modify the PV array parameters and simulation conditions. In order to help the users, this model also provides the parameters of 10 commercial PV arrays.

Design Technology of Photovoltaic Power Generation (태양광 발전 시스템 설계 기술)

  • Lee, Hyun-Hwa;Seo, Beom-Gwan;Shin, Wha-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1095-1097
    • /
    • 2008
  • 본 논문에서는 먼저 10k(Wp)의 PV 어레이를 설계하는 방법을 제시하고, 설계한 10k(Wp)의 PV 어레이는 최저 및 최고 온도를 고려하여 어레이 시스템을 설계하는 방식으로 인버터의 효율적인 운전이 가능하며 부정합에 의한 손실은 3(%)$\sim$5(%)정도 줄일 수 있다.

  • PDF

Performance Estimation Method of Grid-Connected Photovoltaic System (계통연계형 태양광발전시스템의 성능 추정방법)

  • So, Jung-Hun;Lee, Bong-Seob;Yoo, Jin-Su;Hwang, Hye-Mi;Yu, Gwon-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.95-101
    • /
    • 2010
  • This paper presents performance estimation approach of grid-connected photovoltaic(PV) system to predict energy yield from irradiance to PV system using normalized yield model for changing meteorological conditions. The accuracy and validity of proposed performance estimation method is identified by compared measured with estimated yield using monitored data. These results will indicate that it is useful to estimate various loss factors causing the system performance obstruction and enhance the lifetime yield of PV system.

Comparison Researches for Installation of the Module Angles and Array Spacing on Photovoltaic Power System (태양광 발전시스템에서 모듈 설치 각도와 어레이 간격의 비교 연구)

  • Choi, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.162-168
    • /
    • 2009
  • This thesis is based on the research and experiment of the optimal efficiency generation of electric power. The research and experiment were conducted to search the optimal generation of electric power from a specific amount of solar energy from Photovoltaic Power System with a solar position tracker were used. The changes in the array angles and spacing of the PV Module were also taken into account as well. Here are the findings and the conclusions. First of all, based on experiment using the various anglers, the efficiency generation of electric power increased to a maximum of approximately $12{\sim}17$[%] more at the PV module inclination angle of 30[$^{\circ}$] than at the inclination angles of 20[$^{\circ}$] and 40[$^{\circ}$]. As a result, we have found that installing the PV module inclination at the angle of 30[$^{\circ}$] brought about the most efficient conversion effect of the Photovoltaic Power System. But, when the solar cell is installed on a roof or rooftop where snow builds up, it is the most appropriate to install the solar energy at an 35[$^{\circ}$] angle so that snow slides down and not build up on the module.

Electric Circuit Analysis for PV Array on Short-Circuit Failure of Bypass Diode in PV Module (PV모듈의 바이패스 다이오드 단락 고장 시 태양광어레이 회로 특성분석)

  • Lee, Chung-Geun;Shin, Woo-Gyun;Lim, Jong Rok;Hwang, Hye-Mi;Ju, Young-Chul;Jung, Young-Seok;Kang, Gi-Hwan;Chang, Hyo-Sik;Ko, Suk-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.15-25
    • /
    • 2019
  • As the installation of photovoltaic systems increases, fire accidents of PV system grow every year. Most of PV system fires have been reported to be caused by electrical components. The majority of fire accidents occurred in combiner box, which is presumed to be short-circuit accidents due to dustproof and waterproof failures or heat deterioration of blocking diode. For this reason, the blocking diode installation became optional by revised PV combiner regulation. In this paper, according to the revised regulation, reverse current that generated by voltage mismatch was measured and analyzed in PV array without a blocking diode. The factors that cause voltage mismatch in array are assumed to be shaded PV module and short circuit failure of bypass diode. As the result of experiment, there is no reverse current to flow under shading condition in module, but reverse current flows on the failure of bypass diode in module. According to the module's I-V characteristic curve analysis, open voltage was slightly reduced due to operation of bypass diode in shading. However, it showed that open circuit voltage has decreased significantly in the failure of bypass diode. This indicates that the difference in open voltage reduction of voltage mismatch factor causes reverse current to flow.

The Operating Performance Analysis of PV Array for Arch Type (아치형 태양전지 어레이의 출력특성 분석)

  • Piao, Z.G.;Choi, Y.O.;Cho, G.B.;Baek, Hyeong-Rae
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.240-241
    • /
    • 2009
  • 본 논문에서는 다양한 아치형 태양광발전(Photovoltaic : PV) 시스템을 시뮬레이션을 통하여 구성하고 그 운전특성을 최적의 경사각을 가지는 일정 경사각 PV 시스템과 비교 분석하였다. 결과 아치형 PV 시스템의 경우 모두 PV 어레이 경사각이 $30^{\circ}$인 일정 경사형 시스템에 비하여 9% 이상의 큰 차이가 남을 알 수 있었으며, 최적의 아치경사각은 $10^{\circ}\sim30^{\circ}$임을 알 수 있었다.

  • PDF

Analysis of Performance of Balcony Integrated PV System (발코니 일체형 태양광발전시스템의 발전성능 분석)

  • Kim, Hyun-Il;Kang, Gi-Hwan;Park, Kyung-Eun;So, Jung-Hoon;Yu, Gwon-Jong;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.32-37
    • /
    • 2009
  • Photovoltaic(PV) permits the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of building integrated balcony PV system and analyzed both performance and problems of this system. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 74.7%.

The Study of Method about the Multi-channel Simultaneous Measurement for Measuring the I-V Curve of Photovoltaic Array (태양광 어레이 I-V 곡선 측정을 위한 다채널 동시 측정방법에 관한 연구)

  • Park, Yu-Na;Jang, Gil-Soo;Ko, Suk-Whan;Kang, Gi-Hwan;So, Jung-hun;Jung, Young-Seok;Ju, Young-Chul;Hwang, Hye-Mi;Song, Hyung-Jun
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.23-33
    • /
    • 2017
  • A great deal of study for loss reduction of photovoltaic system is conducted currently. It is hard to distinct the fault of photovoltaic system with the naked eye. For that reason, it is essential to repair and maintain the PV system by monitoring the system. The fault of individual modules can cause the huge loss of the entire system because of the mismatch. Therefore, the method of diagnosing the PV array is necessary by measuring the multi-channel arrays simultaneously. In this paper, it is presented the method of measuring I-V curve of multi-channel arrays simultaneously by using the charge and discharge characteristics of capacitor. Generated DC power at PV arrays is charged and discharged at the capacitors in a moment. By measuring the charged voltage and current, it is possible to diagnose of performance of PV arrays.

A Study on PV System Output Changes by PV Array Installation Position and Mount Angle Change (태양광 어레이 설치 위치 및 각도변경 전후의 태양광 발전 시스템의 출력 변화에 관한 연구)

  • Yoon, Jeong-Phil;Cha, In-Su;Choi, Jeong-Sik;Kim, Dong-Mook;Park, Jong Bock;Ha, Min Ho;Kim, Won Bae
    • Current Photovoltaic Research
    • /
    • v.2 no.4
    • /
    • pp.189-194
    • /
    • 2014
  • In this paper, We have simulated the output variation of the PV arrays installation with position & angle change. The existing 3 solar array system are $43^{\circ}$ southeast and each of the mounting angle is $17^{\circ}$. The PV output power is 240 kW. The composite studied systems in this paper arrays altered 2 PV array among 3 PV array system- the output 144kW. We simulated this system using Solar Pro ver.4.1. The simulation conditions are southwest $43^{\circ}/array$, mount angle $27^{\circ}/array$. Because the southeast have shadow effect-higher mountain The purpose of southwest $43^{\circ}$ is reduce the shadow effect. The simulation results of the suggestion design algorithm compared to 1,590 kWh/year output is increased with the southeast.