Numerical Simulation of Fracture Mechanism by Blasting using PFC2D (PFC2D에서의 발파에 의한 파괴 메커니즘의 수치적 모델링)

  • Jong, Yong-Hun;Lee, Chung-In;Jeon, Seok-Won
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.476-485
    • /
    • 2006
  • During blasting, both shock wave and gas are generated in detonation process of explosives and the generated wave and gas expansion may create new fractures and damage rock mass. In order to explain and understand completely the fracture mechanism by blasting, we have to consider both effects of the wave and gas expansion simultaneously. In this study, we use a discrete element code, PFC2D and develop an algorithm which is capable of modeling both detonation and gas pressures acting on blasthole wall and visualizing generated cracks within rock mass. Moreover, the gas-pressure modeling method which applies a corresponding external force of gas pressure to parent particles of radial fractures is adopted to simulate a coopting between rock mass and gas penetrating created radial fractures. The developed algorithm is verified by reproducing numerical simulations of a lab-scale test blast successfully.

An Improved Predictive Functional Control with Minimum-Order Observer for Speed Control of Permanent Magnet Synchronous Motor

  • Wang, Shuang;Fu, Junyong;Yang, Ying;Shi, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.272-283
    • /
    • 2017
  • In this paper, an improved predictive functional control (PFC) scheme for permanent magnet synchronous motor (PMSM) control system is proposed, on account of the standard PFC method cannot provides a satisfying disturbance rejection performance in the case of strong disturbances. The PFC-based method is first introduced in the control design of speed loop, since the good tracking and robustness properties of the PFC heavily depend on the accuracy of the internal model of the plant. However, in orthodox design of prediction model based control method, disturbances are not considered in the prediction model as well as the control design. A minimum-order observer (MOO) is introduced to estimate the disturbances, which structure is simple and can be realized at a low computational load. This paper adopted the MOO to observe the load torque, and the observations are then fed back into PFC model to rebuild it when considering the influence of perturbation. Therefore, an improved PFC strategy with torque compensation, called the PFC+MOO method, is presented. The validity of the proposed method was tested via simulation and experiments. Excellent results were obtained with respect to the speed trajectory tracking, stability, and disturbance rejection.

Development and Application of an Explosion Modeling Technique Using PFC (PFC3D에서의 폭원모델링 기법의 개발 및 적용)

  • Choi Byung-Hee;Yang Hyung-Sik;Ryu Chang-Ha
    • Explosives and Blasting
    • /
    • v.22 no.4
    • /
    • pp.7-15
    • /
    • 2004
  • An explosion modeling technique was developed by using the spherical discrete element code, PFC3D, which can be used to model the dynamic stress wave propagation phenomenon. The modeling technique is simply based on an idea that the explosion pressure should be applied to a PFC3D particle assembly not in the form of an external force (body force), but in the form of a contact force (surface force). According to this concept, the explosion pressure is applied to the wall particles by the scheme of radius expansion/contraction of inner-hole particles. The output wall force is compared to the input hole pressure in every time step, and a correction routine is activated to control the radius multiplier of the inner-hole particles. A comparative blast simulation far a cement mortar block of $80\times90\times80mm$ was conducted by using the conventional explosion modeling method and the new one. The results of the simulation are presented in a qualitative fashion.

Comparative Analysis of Current Controls for Boost PFC Converter under Light Load

  • Juil Kim;Yeong-Jun Choi
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.6
    • /
    • pp.143-151
    • /
    • 2024
  • In this paper, the inductor current distortion in a boost PFC (Power Factor Correction) converter under light load is mathematically analyzed, and its reasons are defined. In the average current mode control under light load, the inductor current is discontinuous, resulting in an inaccurate inductor current average value being reflected in the current control. In predictive current mode control, the current ripple is relatively large compared to the inductor current, leading to severe current distortion. In addition, the switch is turned off near the peak of the inductor current when model predictive current control is applied. Inductor current distortion must be addressed because it leads to an increase in total harmonic distortion and a decrease in power factor. In this paper, the design procedure to mitigate the light load current distortion in boost PFC converter is selected based on the mathematical analysis. Finally, a comparative analysis of control methods under light load is performed using hardware-in-the-loop simulation.

REDUCTION OF VOLTAGE STRESS AND INPUT CURRENT HARMONIC DISTORTION IN SINGLE STAGE PFC CONVERTER BY SELECTIVE VARIABLE FREQUENCY CONTROL (선택적 주파수 변환방식에 의한 단상 역률보상회로의 캐패시터전압 및 입력전류 고조파왜곡의 감소)

  • Choi, Hang-Seok;Lee, Kyu-Chan;Cho, Bo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1999-2001
    • /
    • 1997
  • The main two drawbacks of the Sin91e Stage PFC (SS-PFC) converters employing a DCM Boost PFC cell are relatively high voltage stress on the bulk capacitor and the input current harmonic distortion. The high voltage stress on bulk capacitor makes the SS-PFC converter impractical in a universal input application and the input current harmonic distortion lowers power factor. In this paper a selective variable frequency control that reduces the voltage stress on the bulk capacitor and the input current harmonic distortion is proposed. Computer simulation results of the proposed control method are presented.

  • PDF

Inverter Driven Air-Conditioner With Power Factor Correction Circuit (역률제어회로를 갖는 인버터 구동 에어컨)

  • 권경안;박병욱;김정태;정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.105-110
    • /
    • 1999
  • This paper describes the inverter driven air-condetioner with power factor correction (PFC) circuit. By adopting PFC in the rectifier, we can reduce harmonic injection into power line, improve the efficiency and lower the total system cost compared to conventional inverter only. Also, system performance is improved by stabilizing the output voltage of PFC. In this paper, detailed design procedures for PFC are given, and the several merits with PFC are verified through the simulation and experiment.

A New Zero Voltage Transition Bridgeless PFC with Reduced Conduction Losses

  • Mahdavi, Mohammad;Farzanehfard, Hosein
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.708-717
    • /
    • 2009
  • In this paper a new zero voltage transition PWM bridgeless PFC is introduced. The auxiliary circuit provides soft switching condition for all semiconductor devices. Also, in the resonant path of the auxiliary circuit, only two semiconductor devices exist. Therefore the resonant conduction losses are low. Furthermore, the auxiliary circuit semiconductor elements consist of only one diode and one switch. The proposed auxiliary circuit is applied to a bridgeless PFC converter to further reduce conduction and switching losses. In this paper, the operating modes of this converter are explained and the resulting ideal and simulation waveforms are shown. The presented experimental results justify the theoretical analysis.

Characteristics of a High Power Factor Boost Converter with Continuous Current Mode Control

  • Kim, Cherl-Jin;Jang, Jun-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Switching power supply systems are widely used in many industrial fields. Power factor correction (PFC) circuits have a tendency to be applied in new power supply designs. The input active power factor correction (APFC) circuits can be implemented in either the two-stage approach or the single-stage approach. The two-stage approach can be classified into boost type PFC circuit and dc/dc converter. The power factor correction circuit with a boost converter used as an input power source is studied in this paper. In a boost power factor correction circuit there are two feedback control loops, which are a current feedback loop and a voltage feedback loop. In this paper, the regulation performance of output voltage and compensator to improve the transient response presented at the continuous conduction mode (CCM) of the boost PFC circuit is analyzed. The validity of designed boost PFC circuit is confirmed by MATLAB simulation and experimental results.

Conducted Noise Reduction in PFC Boost Converter for Air Conditioner (에어컨용 PFC Boost Converter의 전도 노이즈 저감)

  • Lee S.H.;Kim L.H.;Kim Y.G.;Won C.Y.;Kim T.D.;Kim D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.793-797
    • /
    • 2003
  • Switching PFC converters are widely used not only to comply the power quality specification but also for maximum efficiency. However switching PFC converters generate serious electromagnetic interference (EMI). In this paper to solve this problem, we applied the APW(Anti Phase Winding) and RPWM(Ran-dom PWM) technique to PFC boost converter and obtained satisfactory results. Simulation and experimental results show the improved harmonic and reduced EMI effect in air-conditioner system.

  • PDF

Soft Switching Bridgeless PFC Buck Converters

  • Emrani, Amin;Mahdavi, Mohammad;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.268-275
    • /
    • 2012
  • Based on the standards that limit the harmonic pollution of electronic systems, the use of PFC converters is mandatory. In this paper, a new resonant bridgeless PFC converter is introduced. By eliminating the input bridge diodes, the efficiency is improved. Moreover, soft switching conditions for all of the semiconductor elements are achieved without adding any extra switches. As a result, high efficiency is attained. The proposed converter is analyzed and the theoretical and simulation results of the proposed converter are presented. In order to verify the validity of the analysis, a 40 w prototype converter is implemented and experimental results are presented. The experimental results show that high efficiency is attained while achieving a high power factor.