시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안 (Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement)

  • 문재승;신민용;안성철;유문곤;김수근
    • 한국의료질향상학회지
    • /
    • 제20권1호
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.

PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰 (A Consideration of Apron's Shielding in Nuclear Medicine Working Environment)

  • 이성욱;김승현;지봉근;이동욱;김정수;김경목;장영도;방찬석;백종훈;이인수
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.110-114
    • /
    • 2014
  • PET/CT기기의 발달로 인한 검사시간의 단축과 대중화로 인해 검사건수도 꾸준히 증가하고 있다. 이는 방사선 작업종사자의 피폭선량도 함께 증가시키는 결과를 초래한다. 본 연구는 PET/CT 검사에 있어서 에너지가 강한 $^{18}F-FDG$를 apron을 착용 시 방사선 차폐율을 측정하고 차폐효과를 알아보고자 하였다. 또한 $^{99m}TC$과의 차폐율을 비교하여 방사선 작업종사자의 피폭선량을 최소화하는 것에 목적을 두고 진행하였다. 실험방법은 2013년 5월 2일부터 5월 10일까지 8일간 PET/CT 검사를 위해 본원을 방문한 10명의 환자를 대상으로 하였고 PET/CT 주요 작업공간인 $^{18}F-FDG$ 분배실, 환자 안정실($^{18F}$주사 후 환자 대기장소), PET/CT 검사실 모두 3곳을 선정하여 Apron장착 전과 apron장착 후로 나누어 선량율 변화를 측정하였다. 정확한 측정을 위해서 환자 또는 Source부터의 거리는 1 m로 고정하였다. 또한 Apron의 선량감소율을 비교하고자 $^{99m}TC$의 source에도 같은 방법을 적용하여 측정하였다. 측정결과 $^{18F}FDG$ 분배실에서 L-BLOCK만 있는 경우 평균 $0.32{\mu}Sv$였고 L-block+apron의 경우 $0.23{\mu}Sv$이였으며 두 경우의 선량과 선량율의 차이는 각각 $0.09{\mu}Sv$, 26%로 나타났다. 안정실에서 apron이 없는 경우 평균 $33.1{\mu}Sv$였고 apron이 있는 경우 평균 $22.3{\mu}Sv$였다. 두 경우의 선량과 선량율의 차이는 각각 $10.8{\mu}Sv$, 33%로 나타났다. PET/CT실에서의 apron이 없는 경우 평균 $6.9{\mu}Sv$였고 apron이 있는 경우 평균 $5.5{\mu}Sv$였다. 두 경우의 선량과 선량율의 차이는 각각 $1.4{\mu}Sv$, 25%로 나타났다. $^{99m}TC$은 apron이 없는 경우 평균 $23.7{\mu}Sv$였고 apron이 있는 경우 평균 $5.5{\mu}Sv$였다. 두 경우의 선량과 선량율의 차이는 각각 $18.2{\mu}Sv$, 77%나타났다. 실험결과 환자에게 투여한 후의 $^{99m}TC$의 경우 평균 77%의 차폐율을 나타내었고 $^{18}F-FDG$의 경우 평균 27%의 비교적 낮은 차폐율을 보였다. source 자체만을 비교하였을 때에 $^{18}F-FDG$는 17%의 차폐율을 보였고 $^{99m}TC$은 77%의 차폐율을 보였다. $^{99m}TC$에 비해 낮은 차폐효과이지만 $^{18}F-FDG$ 역시 apron에 대한 차폐효과가 있음을 알 수 있었다. 그러므로 PET/CT 검사에 있어서 $^{18}F-FDG$과 같은 고에너지에 맞는 apron을 착용한다면 방사선 작업종사자의 피폭선량을 최소화 할 수 있을 것으로 사료된다.

  • PDF

핵의학 검사실내 세균 분석 (Analysis of the Bacteria in Nuclear Medicine)

  • 신성규;이효영
    • 대한안전경영과학회지
    • /
    • 제19권2호
    • /
    • pp.95-100
    • /
    • 2017
  • In this study, the bacterial contamination level of equipments and devices in the nuclear medicine department of a university hospital was investigated. CNS was detected from the sample collected from the door opening button of the nuclear medicine department. Bacillus sp. was detected from the table and CNS with Bacillus sp. were detected from the control button at the PET-CT room no.1. Also, CNS was detected from the table and the control button at the PET-CT room no.2. In the distribution room no.1, CNS and Bacillus sp. were detected while CNS being detected from the distribution room no.2 and CNS with Bacillus sp. being detected from the distribution room no.3. In the injection room, Enterrococcus faecium and Pontoea sp. were detected. On the table of the ecsomatics room, Pontoea sp. was detected. Bacillus sp. was detected from the inside of the syringe Pb shield and CNS was detected from the outside. Enterrococcus faecium was detected from the Gamma camera table and Bacillus sp. was detected from the door grip. On the chair at the patient waiting room, Pseudomonas aeruginosa abd Bacillus sp. were detected. Therefore, it was understood that infection should be prevented by securely sterilizing examination devices after each examination, maintaining cleanliness by regular sterilization of waiting chairs and such objects with a number of direct contacts with patients, and infection education for the features of nuclear department.

온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가 (Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280))

  • 류찬주;김정아;김준수;윤근영;허승희;홍성종
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography)장치는 해부학적 정보를 얻기 위한 CT와 MRI의 장치를 PET 장치와 융합시킨 PET/CT나 PET/MRI 장치로 사용된다. 그렇기 때문에 일반 의료장비들과 비교하여 Gantry(촬영부 본체)의 길이가 늘어나고 내부의 공간이 넓어지는 원형(ring)타입의 구조로 제작된다. PET 장치의 구성요소 중 하나인 신틸레이터는 Gantry 안쪽에 위치하는데 온·습도 변화에 민감한 크리스탈 성분으로 되어있기 때문에 커다란 온도 변화로 인해 신틸레이터의 손상을 가져올 수 있다. 신틸레이터는 항온항습기로 PET장치가 설치되어 있는 공간에 온·습도를 유지하지만 이러한 PET 장치의 구조적 원인과 CT 장비에서 발생하는 열로 인한 Gantry 내부의 온·습도의 변화가 예상된다. 항온항습기를 가동하여 온·습도를 유지중인 PET/CT 장치의 Gantry 내부를 6개의 구역으로 나눈 후 각 구역에 Arduino 온·습도 센서인 Adafruit BME 280을 부착하여 출력 값을 분석했다. 각 6개 구역에서 센서를 이용해 측정한 평균 온·습도 값과 항온항습기의 평균 측정값을 비교하면 평균적으로 온도는 2.71℃ 상승, 습도는 21.5% 감소의 차이가 발생하였고, PET Gantry의 온·습도 측정값은 국내에서 지정한 정도 관리 범위에서 벗어나는 결과 값이 나왔다. 연구 결과를 통해 앞으로 지속적인 온·습도의 변화를 가진다면 PET Gantry 안에 장착된 신틸레이터의 노후화가 예상되므로 Gantry구조 내부의 온·습도를 적절히 유지하는 방안을 모색해야 한다.

핵의학과 PET/CT실 방사선작업종사자의 수정체 부위의 등가선량과 흉부의 유효선량의 측정 비교 (Comparison of the Equivalent Dose of the Lens Part and the Effective Dose of the Chest in the PET/CT Radiation Workers in the Nuclear Medicine Department)

  • 손상준;박정규;정동경;박명환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.209-215
    • /
    • 2019
  • Comparison of the effective dose of the chest and the equivalent dose of the lens site in the radiation workers working at four medical institutions with the PET / CT room located in one metropolitan city and province from April 1 to June 30, 2018 Respectively. Radioactive medicine were measured at the time of dispensing and at the time of injection. In this experiment, the average dispensing time per patient was 5.7 minutes and the average injection time was 3.1 minutes. The equivalent dose at the lens site was $0.78{\mu}Sv/h$ for 1 mCi, and the effective dose for chest was $0.18{\mu}Sv/h$ per 1 mCi. The equivalent dose at the lens site during injection was $0.88{\mu}Sv/h$ per mCi and the effective dose of chest was $0.20{\mu}Sv/h$ per mCi. The daily effective dose of the chest was $0.9{\pm}0.6{\mu}Sv$ and the equivalent dose of the lens site was $3.6{\pm}1.4{\mu}Sv$ during daily dosing for 20 days. The effective dose of the chest during the day was $0.6{\pm}0.5{\mu}Sv$ and the equivalent dose of the lens was $2.2{\pm}1.0{\mu}Sv$. At the time of dispensing, the equivalent dose of the lens was $0.187{\pm}0.035mSv$, the effective dose of the chest was $0.137{\pm}0.055mSv$, the equivalent dose of the lens was $0.247{\pm}0.057mSv$, and the effective dose of the monthly chest was $0.187{\pm}0.021mSv$. As a result of the corresponding sample test, the equivalent dose and the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, The equivalent dose of the lens and the effective dose of the chest were statistically significant (p<0.05) with a significance of 0.000. However, there was no statistically significant difference (p>0.05) between the equivalent dose and the effective dose of the chest, the equivalent dose of the lens at the time of injection, and the effective dose of the chest at 0.138 and 0.230, respectively.

PET/CT 검사 시 체중과 체표면적에 따른 SUV의 상관관계 (Correlation of SUV According to the Body Weight and Body Surface Area in PET/CT Imaging)

  • 박주선;도용호;김정수;이홍재;김진의
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.44-47
    • /
    • 2013
  • PET/CT 검사에서 정량적 지표로 이용되는 SUV를 측정하는 방법 중 $SUV_{bw}$$SUV_{bsa}$를 환자의 BMI에 따라 비교하여 상관관계를 분석하였다. 실험을 위해 사용된 PET/CT scanner는 본원에서 사용하고 있는 Biograph mCT 40 (Siemens, Germany)이다. ROI는 bone, liver, lung에 각각 $4.5cm^2$ 면적으로 그렸으며 Syngo.via VA11A를 사용하여 $SUV_{max}$$SUV_{mean}$을 구하였다. 70명의 환자를 대상으로 시행한 PET/CT 영상으로 $SUV_{bw}$$SUV_{bsa}$를 비교 분석한 결과 환자의 BMI가 커질수록 $SUV_{bw}$$SUV_{bsa}$의 차이가 증가함을 보이며 $SUV_{mean}$보다 $SUV_{max}$에서의 차이가 더 많이 나타났다. Liver에서의 차이는 bone과 lung에 비해 상대적으로 높았고, bone과 lung에서는 유의한 차이는 없었다. 따라서 SUV를 산출하는 방법에 따라 오차가 발생할 가능성이 있으므로, 체중의존성을 줄이기 위해 임상에서는 실정에 맞게 적용하여 시행해야 할 것 으로 사료된다.

  • PDF

생성적 적대 신경망(Generative Adversarial Network)을 이용하여 획득한 18F-FDG Brain PET/CT 인공지능 영상의 비교평가 (Comparative Evaluation of 18F-FDG Brain PET/CT AI Images Obtained Using Generative Adversarial Network)

  • 김종완;김정열;임한상;김재삼
    • 핵의학기술
    • /
    • 제24권1호
    • /
    • pp.15-19
    • /
    • 2020
  • 본 연구는 최근에 활발히 연구되고 있는 딥러닝 기술인 생성적 적대 신경망(GAN)을 핵의학 영상에 적용하여 잠재적으로 유용성이 있는지 확인해보고자 하였다. 본원에서 18F-FDG Brain PET/CT검사를 진행한 30명의 환자를 대상으로 하였고 List모드로 15분 검사한 후 이를 1, 2, 3, 4, 5분 초기획득시간 이미지로 재구성하였다. 이 중 25명의 환자를 GAN모델의 학습을 위한 트레이닝 이미지로 사용하고 5명의 환자를 학습된 GAN모델의 검증을 위한 테스트 이미지로 사용하였다. 학습된 GAN모델에 입력으로 1, 2, 3, 4, 5분의 초기획득 이미지를 넣고 출력으로 15분 인공지능 표준획득 이미지를 획득한 후 이를 기존의 15분 표준획득시간 검사 이미지와 비교 평가하였다. 평가에는 정량화된 이미지 평가방법인 평균제곱오차, 최대신호 대 잡음비, 구조적 유사도 지수를 이용하였다. 평가 결과 초기획득시간 이미지에서 1에서 5분으로 갈수록 실제 표준획득시간 이미지에 가까운 평균제곱오차, 최대신호 대 잡음비, 구조적 유사도 지수 수치를 나타내었다. 이러한 연구를 통해 앞으로 인공지능 기술이 핵의학 분야에서 의료영상의 획득시간 단축과 관련하여 중요한 영향을 미칠 수 있을 것으로 사료된다.

병원에서의 환자, 의료진의 전자파 노출 실태 조사 (Research of operators and patients exposed to electromagnetic field in the hospital)

  • 지효철;홍현기;김성우;이주형;김덕원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.70-72
    • /
    • 2007
  • In this study, electromagnetic fields emitted from the various environment in the hospital were measured. Measurement spot was patients' head. To monitor how much magnetic fields are emitting from operation room, monitoring device was attached to 19 anesthesiologist and monitoring lasted 8 hours. We also took a measurement from various medical devices. Devices include ESWL, PET, MRI, CT, Gamma knife, X-ray, Angiogram, Echocardiogram, Upper GI and Linear Accelerator. Electromagnetic fields were measured from 10 spots from each of 5 patient waiting room. As a results, there were no places showing risk of high exposure. All the measurement values were below the reference levels for general public exposure to time varying electric and magnetic fields which is issued by ICNIRP.

  • PDF

의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구 (A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job)

  • 강천구;오기백;박훈희;오신현;박민수;김정열;이진규;나수경;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.9-16
    • /
    • 2010
  • 본 연구는 방사성동위원소의 의학적 이용도가 증가함에 따라 의료기관 핵의학과 방사선 관계종사자의 직무 별 방사선 이용에 대한 개인 방사선 피폭선량의 실태를 파악하여, 방사선 위험에 대해 경각심을 고취시키고, 방사선 관계종사자들에게 안전관리와 합리적인 피폭선량 관리에 도움을 주고자 분석하였다. 2007년 1월 1일부터 2009년 12월 31일까지 의료기관에서 근무하는 핵의학 방사선 관계종사자로 분류되어 개인 방사선피폭선량 측정을 정기적, 연속적으로 3년 간 조사 관리된 40명의 종사자를 대상으로 직종 별, 영상실 별, 연령 별, 선량구간 별, 직무 별 관련업무를 파악하여 심부선량에 대하여 연간평균피폭선량을 각각 분석하였다. 분석법으로는 빈도분석과 ANOVA를 시행하였다. 3년 간 영상실 별 연간피폭선량은 PET 및 PET/CT 영상실이 11.06~12.62 mSv로 가장 높은 피폭선량을 보였고, 감마카메라 주사실이 11.72 mSv로 높았으며, 직종 별 연간평균피폭선량은 임상병리사가 8.92 mSv로 가장 높았고, 방사선사 7.50 mSv, 간호사 2.61 mSv, 연구원 0.69 mSv, 접수 0.48 mSv, 의사 0.35 mSv 순으로 나타났으며, 세부업무에 따른 직무별 연간평균피폭선량은 PET 및 PET/CT 업무가 12.09 mSv로 가장 높은 피폭선량을 보였으며, 감마카메라 주사실이 11.72 mSv, 싸이크로트론 관련 합성 업무 8.92 mSv, 감마카메라 영상업무 4.92 mSv, 치료 및 안전관리 2.98 mSv, 간호사 업무 2.96 mSv, 관리 업무 1.72 mSv, 영상분석 업무 0.92 mSv, 판독업무 0.54 mSv, 접수업무 0.51 mSv, 연구업무 0.29 mSv 순으로 나타났다. 선량구간 별 연간평균피폭선량은 연구대상자의 15명(37.5%)이 1 mSv이하의 선량분포와 5명(12.5%)이 1.01~5.0 mSv이하의 선량분포를 가지고 있었고, 5.01~10.0mSv에서 14명(35.0%), 10.01~20.0 mSv에서 6명(15.0%)의 분포로 분석되었다. 연령에 따른 연간평균피폭선량은 방사선사 직종에서는 25~34세 종사자가 8.69 mSv로 가장 높은 평균선량을 보였고, 근무기간에 따른 연간평균피폭선량은 방사선사 직종에서 5~9년 종사자가 9.5 mSv로 가장 높은 평균선량을 나타냈다. 고용형태에 따른 연간평균피폭선량은 정규직 임상병리사 8.92 mSv, 방사선사 7.82 mSv, 계약직 방사선사 7.55 mSv, 인턴직 방사선사 5.62 mSv, 계약직 간호사 2.61 mSv, 정규직 연구원 0.69 mSv, 접수 0.55 mSv, 의사 0.35mSv 순으로 피폭을 받는 것으로 나타났다. 이와 같은 결과로 볼 때 의료기관에서 근무하는 핵의학 방사선 관계종사자의 대부분이 현재의 방사선 안전관리가 실효성 있게 이루어지고 있었으며, 직무특성에 따라 많은 차이가 있는 것을 알게 되었다. 그러나 방사선 피폭을 최소화시키는 노력이 필요하며, 이를 위해서 체계적 교육과 합리적 피폭량 관리를 위한 체계가 필요하다고 사료된다.

  • PDF

Comparison and evaluation of 89Zr-labeled trastuzumab and Thio-trastuzumab : a potential immuno-PET probe for HER2-positive carcinomas

  • Un Chol Shin;Seoku Bae;Suk-man Kim;Min-Woo Lee;Han Sang Jin;Hyun Park;Kyo Chul Lee;Jung Young Kim;Ji Woong Lee
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.105-111
    • /
    • 2021
  • 89Zr is a positron-emitting radioisotope, which has known as well-suited radioisotope for use in a monoclonal antibody-based imaging agent for immuno-PET. The purpose of this study was to quantitatively evaluate the diagnostic ability of general trastuzumab and thio-trastuzumab as HER2 positive receptors based on Df hexadentate iron chelator. Desferrioxamine-p-SCN (Df-Bz-NCS) and desferroixamine-maleimide (Df-Mal) were purchased from Macrocyclics (Dallas, TX, USA). The trastuzumab was purchased from Roche (Schweiz), and thio-trastuzumab was obtained from professor Hyo-Jeong Hong group (Kangwon National University). The radioisotope 89Zr was produced by domestic purification system and KIRAMS using medical cyclotron (50 MeV, Scantronix). The conjugates of Df-trastuzumab and Df-thio-trastuzumab were prepared with Df-Bz-NCS and Df-Mal under basic aqueous solution (pH 8-9) at room temperature, respectively. The conjugates purified by PD-10 column were mixed with dried 89Zr chloride. 89Zr-labeled conjugates were purified and concentrated by Amicon ultra centrifugal filter. The preparation step and time of 89Zr-labeled conjugates was shorted as 4 steps within 2 hours. 89Zr-labeled conjugates showed the highly radiochemical purity of over 98%, and were very stable until 7 days by the analysis of radio-ITLC method. Each radio-labeled conjugates were also exhibited the highly stability in both PBS buffer and mouse serum. Immuno-PET imaging of 89Zr-labeled conjugates in mice bearing gastric cancer xenograft tumors with HER2 expression showed high tumor uptake in the NCI-N87 HER2-expressing. However, 89Zr-Df-Mal-thio-trastuzumab showed a relatively lower tumor-to-background ratio than 89Zr-Df-Bz-trastuzumab, as well as whole-body distribution. In the results, 89Zr-Df-Bz-trastuzumab was evaluated to have a relatively higher HER2 diagnostic ability than 89Zr-Df-Mal-thio-trastuzumab.