Abstract

Comparison of the effective dose of the chest and the equivalent dose of the lens site in the radiation workers working at four medical institutions with the PET / CT room located in one metropolitan city and province from April 1 to June 30, 2018 Respectively. Radioactive medicine were measured at the time of dispensing and at the time of injection. In this experiment, the average dispensing time per patient was 5.7 minutes and the average injection time was 3.1 minutes. The equivalent dose at the lens site was $0.78{\mu}Sv/h$ for 1 mCi, and the effective dose for chest was $0.18{\mu}Sv/h$ per 1 mCi. The equivalent dose at the lens site during injection was $0.88{\mu}Sv/h$ per mCi and the effective dose of chest was $0.20{\mu}Sv/h$ per mCi. The daily effective dose of the chest was $0.9{\pm}0.6{\mu}Sv$ and the equivalent dose of the lens site was $3.6{\pm}1.4{\mu}Sv$ during daily dosing for 20 days. The effective dose of the chest during the day was $0.6{\pm}0.5{\mu}Sv$ and the equivalent dose of the lens was $2.2{\pm}1.0{\mu}Sv$. At the time of dispensing, the equivalent dose of the lens was $0.187{\pm}0.035mSv$, the effective dose of the chest was $0.137{\pm}0.055mSv$, the equivalent dose of the lens was $0.247{\pm}0.057mSv$, and the effective dose of the monthly chest was $0.187{\pm}0.021mSv$. As a result of the corresponding sample test, the equivalent dose and the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, The equivalent dose of the lens and the effective dose of the chest were statistically significant (p<0.05) with a significance of 0.000. However, there was no statistically significant difference (p>0.05) between the equivalent dose and the effective dose of the chest, the equivalent dose of the lens at the time of injection, and the effective dose of the chest at 0.138 and 0.230, respectively.

Keywords

References

  1. Kim BN, Cho SW, Lee JY, Yoo KR, Park HH. A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT. Journal of Radiological Science and Technology. 2015;38(1):23-30. https://doi.org/10.17946/JRST.2015.38.1.04
  2. Sin GS, Dong KR. The Difference of Standardized Uptake Value on PET-CT According to Change of CT Parameters. Journal of Radiological Science and Technology. 2007;30(4):373-9.
  3. Park SK, Lee NG, Namgoog CK, Jung WY. The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}f$-FDG Wholebody PET. The Korean Journal of Nuclear Medicine Technology. 2010;14(2):100-3.
  4. Park JC, Pyo SJ. Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers. Journal of Radiological Science and Technology. 2012;35(2):141-9.
  5. Kang BS, Kim KH, Kim DY, Kim SC, Kim WR, Kim JG, et al. Radiation Health Management; 2009.
  6. Song HJ. Dose evaluation of nuclear medicine radiation workers using electronic dosimeter [master's thesis]. Perth: University of Choseon; 2017.
  7. Lee JG. ICRP Publications 103. International Radiation Protection Committee; 2008.
  8. Jang KH. Dose management at medical institutions. Medical Radiation Safety Symposium; 2013.
  9. Korea Nuclear Cooperation Foundation, Analysis and evaluation technology of radiation protection system at home and abroad; 2011.
  10. International Atomic Energy Agency, Radiation protection and safety of radiation sources international basic safety standards. General Safety Requirements Part 3; 2011.
  11. Clement CH. ICRP Statement on tissue reactions and early and late effects of radiation in normal tissues and organs-threshold doses for tissue reactions in a radiation protection context. ICRP Publication; 2012.
  12. Kim MG, Choi DH, Kim H, Cho A, Park SY, Kim SH. Prediction of midline depth from skin to cervical epidural space by lateral cervical spine X-ray. Anesth Pain Med. 2017;12(1):68-71. https://doi.org/10.17085/apm.2017.12.1.68
  13. Kim MJ, Kim JH. Radiation exposure and protection for eyes in pain management. Anesth Pain Med. 2017;12(4):297-305. https://doi.org/10.17085/apm.2017.12.4.297
  14. Kim TW. Appraisal of the operational quantities for protection of eye lens against photon and electron radiation [master's thesis]. Perth:University of Hanyang; 2014.
  15. Reu YH, Seo MY, Dong KR. Survey of awareness on the exposure dose of extremity and eye lens by radiation worker in nuclear medicine department. J. of Advanced Engineering and Technology. 2015;8(3):211-7. https://doi.org/10.35272/jaet.2015.8.3.211