Response Characteristics of Acoustic Emission Sensor according to Partial Discharge Quantities (부분방전 전하량에 따른 음향방출 센서의 응답특성)

  • Jeong, Yeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.383-387
    • /
    • 2010
  • The response characteristics of AE (acoustic emission) sensors with a coupled vibration mode and a non-coupled vibration mode were investigated according to PD(partial discharge) quantities in XLPE (cross linked polyethylene) sheets and craft papers immersed in insulating oil. The response voltages of a coupled vibration mode AE sensor were linearly proportional to the PD quantities up to 1,000 pC in XLPE sheets, while a non-coupled vibration mode AE sensor did not show the similar linearity. In case of a test of craft papers immersed in insulating oil, a linearity between response voltages and PD quantities was observed up to 550 pC, but after that, similar linearity between response voltage of any types of AE sensor and PD quantities was not shown.

Properties of Partial Discharge accompanying with Electrical Tree in LDPE (저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성)

  • 이광우;박영국;강성화;장동욱;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

Analysis of Insulation Aging in Operating High Voltage Motors (운전중인 고압전동기에서 절연열화 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2175-2178
    • /
    • 2005
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in five high voltage motors(rated 6.6kV). These high voltage motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on five motors. These motors were energized to 3.81kV. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Internal discharges were generated in phase A, B and C of COP-B and pulv.-B, in phase B of Pulv. C and in phase C of Pulv.-D motor. Discharge at conductor surface was discovered in phase A of Pulv. D motor. Slot discharges occurred in three phases of Pulv. E motor.

  • PDF

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일의 부분방전 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2091-2093
    • /
    • 2005
  • Five model coils of 6.6kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals, respectively The voltage applied to the coils was 3.81kV, 4.76kV, 6.0kV and 6.6kV. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector (PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns coincide with both PDD and TGA.

  • PDF

Properties of Distribution of PD Pulses accompanying with Propagation of bush-type Tree (부시형 전기트리의 성장에 따른 부분방전 펄스의 분포 특성)

  • Kang, S.H.;Jung, S.H.;Lee, K.W.;Jang, D.U.;Ryu, B.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1478-1480
    • /
    • 1998
  • Inception and propagation of electrical tree and properties of partial discharge(PD) pulses accompanying with tree in low density polyethylene were discussed. We observed the characteristics of process of electrical tree by using optical microscope and investigated the statistical characteristics of the PD pulses by analyzing PD quantities and distribution patterns. The PD pulses were analyzed by q-n, $\phi$-n and $\phi$-q distribution. The statistical operators used were skewness(s), kurtosis(k) and average phase angle. The skewness and average discharge phase angle of PD pulses increased as the Propagation of tree. The kurtosis was about 1.8 at the Inception of tree, but It increased as the propagation of tree.

  • PDF

Properties of PD Pulses accompanying with Electrical Tree in LDPE (LDPE에서 전기트리에 수반된 부분방전 펄스의 특성)

  • Park, Y.G.;Bae, M.H.;Kang, S.H.;Lim, K.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1507-1509
    • /
    • 1997
  • Property of insulation of electric machine is severely affected by process of electrical tree growing. Partial discharges(PD) have been used to determine degradation of insulations. In this paper, PD quantities detected and analyzed are PD magnitudes, repetition rates, phase angle distribution of PD pulses, and wavelet transformation. The wavelet transformation is an extended method of fourier transformation. The fourier transformation is a powerful tool for signal analysis, but it can't include informations for time. However the wavelet transformation analysis can include on the informations of time and frequencies at the same time. This paper discusses correlation between process of electrical tree growing and characteristics of PD in LDPE specimens.

  • PDF

Characteristics of Insulation Aging in 4.16kV Motor Stator Windings (4.16kV 전동기 고정자 권선의 절연열화 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1381_1382
    • /
    • 2009
  • Nondestructive tests were performed on two 4.16kV motors. Epoxy-mica coupler(80pF) was connected to 4.16 kV motor stator windings. The voltage applied to the stator windings was 2.4 kV, 3.0kV, 3.5kV and 4.16kV, respectively. Digital partial discharge detector(PDD) and turbine generator analyzer(TGA) were used to measure partial discharge(PD) activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of stator windings were indicated the internal discharge. PD patterns are consistent with the result of measurement using PDD and TGA.

  • PDF

A Study on Partial Discharge Measurement using Optical Fiber Sensors (광섬유 센서를 이용한 부분방전 측정연구)

  • Lee, June-Ho;Lee, Cheol-Kyou
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.922-924
    • /
    • 1998
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Mach-Zehnder interferometer were proposed to detect the partial discharge signals in insulating oil. At first the AC breakdown signals were detected to check the response of the OF sensor. The detected signals from OF sensor was consistent with that from current probe. After the response checking, simultaneous measurements and continuous recording were made of electrical and the OF sensor signals from partial discharge(PD) produced by IEC(b) electrode system immersed in insulating oil. The continuous recording made it possible to extract basic quantities of PD from the OF sensor signals, such as pulse phase and pulse amplitude distribution. Through the signal analysis, the absolute peaks of the OF sensor PD signal was found to be increased with the amplitude of electrical signals, and these results mean that there is a strong correlation between OF sensor and electrical PD signals. It was demonstrated that the OF sensor in this research had a possibility to detect the PD signals in power apparatus.

  • PDF

The Normalization and Statistical Distril in Partial Discharge Quantities and Patter (PD패턴과 방전량의 통계적 분포 및 정규화)

  • Lim, Jang-Seob;Lee, Jin;Kim, Duck-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.161-164
    • /
    • 1999
  • Estimation system of aging diagnosis using partial discharge(PD) is being highlighted as a research area for the residual lifetime pridiction of industrial equipment. But the application of PD requires complicated analysis method as expert system because the PD has complex progressing forms according to external stress. In this paper, it has been investigated the statistical distribution to express the 2D PD patterns of the diagnosis system using neural network(NN).

  • PDF

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일에서 부분방전 분석)

  • Kim, Hee-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.178-182
    • /
    • 2006
  • Five model coils of 6.6 kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals. The voltage applied to the coils was 3.81 kV, 4.76 kV, 6.0 kV and 6.6 kV, respectively. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns are consistent with the result of measurement using PDD and TGA instruments. AC breakdown test was performed on five model coils in order to confirm the result of PD measurements. All the failures were located in a line-end coil at the exit from the core slot.