• 제목/요약/키워드: PD pattern

검색결과 239건 처리시간 0.022초

파킨슨병 변증 유형 및 지표 분포에 대한 전향적 다기관 관찰연구 프로토콜 (An Observational Multi-Center Study Protocol for Distribution of Pattern Identification and Clinical Index in Parkinson's Disease)

  • 조혜연;권오진;서복남;박성욱;유호룡;장정희
    • 대한한방내과학회지
    • /
    • 제45권1호
    • /
    • pp.1-10
    • /
    • 2024
  • Objectives: This study investigated the pattern identification (PI) and clinical index of Parkinson's disease (PD) for personalized diagnosis and treatment. Methods: This prospective observational multi-center study recruited 100 patients diagnosed with PD from two Korean medicine hospitals. To cluster new subtypes of PD, items on a PI questionnaire (heat and cold, deficiency and excess, visceral PI) were evaluated along with pulse and tongue analysis. Gait analysis was performed and blood and feces molecular signature changes were assessed to explore biomarkers for new subtypes. In addition, unified PD rating scale II and III scores and the European quality of life 5-dimension questionnaire were assessed. Results: The clinical index obtained in this study analyzed the frequency statistics and hierarchical clustering analysis to classify new subtypes based on PI. Moreover, the biomarkers and current status of herbal medicine treatment were analyzed using the new subtypes. The results provide comprehensive data to investigate new subtypes and subtype-based biomarkers for the personalized diagnosis and treatment of PD patients. Ethical approval was obtained from the medical ethics committees of the two Korean medicine hospitals. All amendments to the research protocol were submitted and approved. Conclusions: An objective and standardized diagnostic tool is needed for the personalized treatment of PD by traditional Korean medicine. Therefore, we developed a clinical index as the basis for the PI clinical evaluation of PD. Trial Registration: This trial is registered with the Clinical Research Information Service (CRIS) (KCT0008677)

견인전동기용 고정자 코일의 Off-line 부분방전 진단을 위한 NN의 적용 (An Application of NN on Off-line PD Diagnosis to Stator Coil of Traction Motor)

  • 박성희;임기조;강성화
    • 한국전기전자재료학회논문지
    • /
    • 제18권8호
    • /
    • pp.766-771
    • /
    • 2005
  • In this study, PD(partial discharge) signals which occur at stator coil of traction Motor are acquired these data are used for classifying the PD sources. NN(neural network) has recently applied to classify the PD pattern. The PD data are used for the learning process to classify PD sources. The PD data come from normal specimen and defective specimens such as internal void discharges, slot discharges and surface discharges. PD distribution parameters are calculated from a set of the data, which is used to realize diagnostic algorithm. NN which applies distribution parameters is useful to classify the PD patterns of defective sources generating in stator coil of traction motor.

뉴우럴 네트워크에 의한 부분방전 패턴 인식 (Partial Discharge Pattern Recognition using Neural Network)

  • 이준호;수적직유;강본달희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1304-1306
    • /
    • 1995
  • In this study, a neural network algorithm through a data standardization method was developed to discriminate the phase-shifted partial discharge(PD) patterns such as a $\phi$-q-n pattern. Considering the PD measurement in the field, it is not so easy to acquire absolute phase angles of PD pulses. As a consequence, one of the significant problems to be solved in applying the neural network algorithm to practical systems is to develop a method that can discriminate phase-shifted $\phi$-q-n patterns. Therefore, authors established a new method which could convert phase-shifted $\phi$-q-n patterns to a standardized $\phi$-q-n pattern which was not influenced by phase shifting. This new standardization method improved the recognition performance of a neural network for the phase-shifted $\phi$-q-n patterns considerably.

  • PDF

저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성 (Properties of Partial Discharge accompanying with Electrical Tree in LDPE)

  • 이광우;박영국;강성화;장동욱;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

교류전압에서 PD 패턴 및 유전체 장벽 방전에 미치는 공간전하의 영향 (The Effect of Space Charge on the PD Pattern and Dielectric Barrier Discharge under AC)

  • 권윤혁;황보승;이동영;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권4호
    • /
    • pp.226-231
    • /
    • 2000
  • In this paper, we present new method to analyze the space charge effect on the electrical characteristics in polymer. It is new measurement system and analysis method that have not reported yet. By using this measurement system, we make observation to space charge accumulated on the surface of polymer at AC voltage, so it is examined to verify the correlation of space charge and partial discharge(PD). In the result of experiment, it can be known that PD pattern is related more closely to space charge accumulated on the surface of polymer than in the inner part, and applied voltage in the air is ruled by this dynamic partial discharge. Also, above critical voltage, the space charge accumulated on the surface of polymer have no effect to the magnitude of PD and the applied voltage in the air. It has been known that the electric power of the dissolution system is proportioned to the frequency and the magnitude of applied voltage, but we can know by this result of the experiment that the efficiency of the dissolution is not related to the rise of voltage above critical voltage.

  • PDF

Partial Discharge Properties of PET Film with Carbon Black

  • Lee, Young-Hwan;Lee, Jong-Chan;Park, Yong-Sung;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.1-4
    • /
    • 2004
  • This paper presents an investigation of the phase-resolved partial discharge (PD) pattern of PET (Poly Ethylene Telephthalate) films with carbon black particles. The phase-resolved PD pattern and statistical parameter from PET samples according to the number of included semiconductor particles were measured. The measurement system consisted of a conventional PD detector using a digital signal processing technique. The partial discharge patterns of the PET films that include the semiconductor particles were investigated to simulate an actual situation that may exist in the cable. In addition, difference of PD patterns between semiconducting particles in PET films and artificial voids was studied. The relationship between the numbers of semiconductor particles in PET films was discussed through the difference of Ψ-q-n distribution and statistical analysis.

154kV XLPE 케이블 실선로 부분방전 검출 (Partial Discharge Measurement for 154kV XLPE Cable Line)

  • 김충식;이전선;김종철;박창기;석광현;김원년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.23-25
    • /
    • 2004
  • HFPD(High Frequency Partial Discharge) measurement has been widely performed to diagnose cable system in the world. Shin-Yeongdeungpo 345kV XLPE line was successfully diagnosed by PD measurement methode last year. Moreover, aged power cable lines which were installed 15 years ago have been tested from this year. In this paper, the result of PD diagnosis for aged 154kV cable line is reported. The PD pattern from TMJ which was monitored by PD measurement system for several days showed typical void pattern. The joint was replaced and voids between semi-conductor layer and insulating layer in the joint was founded.

  • PDF

GIS 부분방전 패턴의 프랙탈 해석 (Fractal Analysis of GIS PD Patterns)

  • 최호웅;김은영;민병운;이동철;김희수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.55-56
    • /
    • 2006
  • In prevention and diagnostic system of GIS, pattern classification is focused on the detection of unnatural patterns in PD(Partial discharge) image data. Fractals have been used extensively to provide a description and to model mathematically many of the naturally occurring complex shapes, such as coastlines, mountain ranges, clouds, etc., and have also received increased attention in the field of image processing, for purposes of segmentation and recognition of regions and objects present in natural scenes. Among the numerous fractal features that could be defined and used for image data, fractal dimension and lacunarity have been found to be useful for recognition purposes Partial discharge(PD) occuring in GIS system is a very complex phenomenon, and more so are the shapes of the various 2-d patterns obtained during routine tests and measurements. It has been fairly well established that these pattern shapes and underlying defects causing PD have a 1:1 correspondence, and therefore methods to describe and qunatify these pattern shapes must be explored, before recognition systems based on them could be developed. The computed fractal features(fractal dimension and lacunarity) for standard library of PD data were analyzed and found to possess fairly reasonable pattern discriminating abilities. This new approach appears promising, and further research is essential before any long-term predictions can be made.

  • PDF

전력 케이블에서 발생되는 방전 신호의 분포패턴에 관한 특성 분석 (Characteristic Analysis on the Distribution Pattern of Discharge Signals Generated in the Power Cable)

  • 소순열;홍경진;정우성;임장섭;이진;이준웅;김태성
    • 한국전기전자재료학회논문지
    • /
    • 제11권11호
    • /
    • pp.1035-1042
    • /
    • 1998
  • After the 1990's, a computer-aided partial discharge(PD) measurement system was referred in part of aging diagnosis using digital signal processing as the new technology has been studied. The PD patterns and relevant information for pattern recognition are discussed in PD research area, because discharge quantity(q), the number of discharge pulse(n) and the applied boltage phase($\varphi$) was combined with the system information of the aging state. This paper investigates the discharge phase and quantity, as well as the number of discharge(n) with regard to discharge signals generated in power cable. therefore, according to characteristic analysis on the distribution of $\varphi$, q and n, it is able to apply in the aging analysis of power cable which visual observation is impossible and distribution change of discharge signals offers much information for risk degree on aging progress of insulation materials.

  • PDF

전력케이블의 절연결함에 따른 부분방전 특성분석 (Analysis of PD Characteristics by Types of Insulation Defects in Power Cables)

  • 최재성;박찬용;김선재;한주섭;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1977-1983
    • /
    • 2009
  • This paper described partial discharge(PD) patterns depending on types of insulation defects in CNCO-W cable(Concentric Neutral Closs-linked Polyethylene Insulated Polyolefin-Water Proof Sheathed Power Cable). The PD measurement system consists of a coupling network, a detection impedance, and a low noise amplifier. A 16 bit, 250 MS/s data acquisition system was used to analyze PD patterns. To simulate insulation defects in a power cable, a needle with the curvature radius of $10{\mu}m$ was inserted into the insulation part. We measured phase ($\Phi$), magnitude (q), and counts (n) of PD pulse for the defects, and classified PD patterns using the PRPD (phase Resolved Partial Discharge) method. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to the types of defect.

  • PDF