• Title/Summary/Keyword: PAR test

Search Result 47, Processing Time 0.024 seconds

Evaluation of hydrogen recombination characteristics of a PAR using SPARC PAR experimental results

  • Jongtae Kim;Jaehoon Jung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4382-4394
    • /
    • 2023
  • Passive auto-catalytic recombiners (PARs) are widely used to mitigate a hydrogen hazard. The first step to evaluate the hydrogen safety by PARs is to obtain qualified test data of the PARs for validation of their analytical model. SPARC PAR tests SP8 and SP9 were conducted to evaluate the hydrogen recombination characteristics of a honeycomb-shaped catalyst PAR. To obtain the hydrogen recombination rate from the PAR test data, two methods, Method-1 and Method-2, introduced by the THAI project, were applied. Since a large gradient of hydrogen concentration developed during hydrogen injection can cause a large error in the hydrogen mass obtained by integrating the measured hydrogen concentrations, a gate was installed at the PAR inlet to homogenize hydrogen in the test vessel before the PAR operation in the tests. A computational fluid dynamics (CFD) code with a PAR model was also applied to evaluate the characteristics of the PAR recombination according to the PAR inlet conditions, and the results were compared with those from Method-1 and Method-2. It was confirmed that the recombination rates from Method-1 require a correction factor to be compatible with results from Method-2 and the CFD simulation in the case of the SPARC-PAR tests.

Prediction on Ultimate Vertical and Horizontal Bearing Capacity of Steel Pipe Piles by Means of PAR (PAR에 의한 강관 말뚝의 극한 수직 및 수평 지지력 예측)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-24
    • /
    • 1997
  • A predicting method for ultimate vertical and horizontal bearing capacity by means of PAR(Pile Analysis Routines) was suggested. Based on the static pile load test data, case studies by means of PAR were performed. Ultimate pile capacity predicted by PAR was within 15% error range of that determined by stairs pile load tests. Also, the results of static pile load test, statnamic tests and PDA data performed on pipe piles were compared and, by using PAR, ultimate pile capacity was determined. Distributions of atrial pile load could be predicted and load transfer analysis could be done approximately by those distributions.

  • PDF

Comparison of Treatment Outcome Assessment for Class I Malocclusion Patients: Peer Assessment Rating versus American Board of Orthodontics-Objective Grading System

  • Hong, Mihee;Kook, Yoon-Ah;Baek, Seung-Hak;Kim, Myeng-Ki
    • Journal of Korean Dental Science
    • /
    • v.7 no.1
    • /
    • pp.6-15
    • /
    • 2014
  • Purpose: The purpose of this retrospective study is to investigate the degree of coincidence between the peer assessment rating (PAR) index and American Board of Orthodontics objective grading system (ABO-OGS) in the assessment of orthodontic treatment outcomes of Class I malocclusion cases. Materials and Methods: The sample consisted of 26 Class I patients. The PAR index was used for evaluation of pre-(T0) and posttreatment (T1) casts, and the ABO-OGS for assessment of T1 casts. If there was a reduction in PAR scores from T0 to T1 of more than 30%, the label 'PAR+' was given to the case, and if not, it was labeled 'PAR-'. If the ABO-OGS was less than 27, the label 'OGS+' was given to the case and if not, it was labeled 'OGS-'. 'A PAR-only qualified group' (PAR+), 'ABO-OGS-only qualified group' (OGS+), 'both indices qualified group' (PAR+/OGS+), and 'both indices disqualified group' (PAR-/OGS-) were compared with a Wilcoxon rank-sum test, sensitivity/specifi city test and Spearman's correlation test. Result: PAR scores for T0, T1, and percentage reduction were 21.1, 6.4, and 65.9%, respectively, and 35.4 for ABOOGS. The distribution of the 'PAR+/OGS+', 'PAR+', and 'PAR-/OGS-' group was 19.3%, 76.9%, and 3.8%, respectively. The T0-PAR, T1-PAR and PAR point reductions for the 'PAR+' group were significantly higher than those of 'PAR+/OGS+' groups (23.1 vs. 15.6; 6.7 vs. 4.6; and 16.5 vs. 11.0; all P<0.05). However, the PAR-percentage reduction and treatment duration between the two groups were not statistically different (70.0% vs. 67.0%, P=0.4325; 24.1 months vs. 25.0 months, P=0.4057). The T1-ABO-OGS score for 'PAR+' group was significantly higher than that of the 'PAR+/OGS+' groups (38.2 vs. 24.0, P<0.001). Conclusion: Since the fraction of the 'PAR+/OGS+' group was less than 20% and there was no significant correlation between PAR-percentage reduction and T1-ABO-OGS, development of a new index system for the accurate evaluation of treatment outcome is needed.

Effects of Tissue Factor, PAR-2 and MMP-9 Expression on Human Breast Cancer Cell Line MCF-7 Invasion

  • Lin, Zeng-Mao;Zhao, Jian-Xin;Duan, Xue-Ning;Zhang, Lan-Bo;Ye, Jing-Ming;Xu, Ling;Liu, Yin-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.643-646
    • /
    • 2014
  • Objective: This study aimed to explore the expression of tissue factor (TF), protease activated receptor-2 (PAR-2), and matrix metalloproteinase-9 (MMP-9) in the MCF-7 breast cancer cell line and influence on invasiveness. Methods: Stable MCF-7 cells transfected with TF cDNA and with TF ShRNA were established. TF, PAR-2, and MMP-9 protein expression was analyzed using indirect immunofluorescence and invasiveness was evaluated using a cell invasion test. Effects of an exogenous PAR-2 agonist were also examined. Results: TF protein expression significantly differed between the TF cDNA and TF ShRNA groups. MMP-9 protein expression was significantly correlated with TF protein expression, but PAR-2 protein expression was unaffected. The PAR-2 agonist significantly enhanced MMP-9 expression and slightly increased TF and PAR-2 expression in the TF ShRNA group, but did not significantly affect protein expression in MCF-7 cells transfected with TF cDNA. TF and MMP-9 expression was positively correlated with the invasiveness of tumor cells. Conclusion: TF, PAR-2, and MMP-9 affect invasiveness of MCF-7 cells. TF may increase MMP-9 expression by activating PAR-2.

Interfacial Adhesion Properties of Surface Treated Polyarylate Fiber with Polyethylene Naphthalate (폴리아릴레이트 섬유의 표면처리에 의한 폴리에틸렌 나프탈레이트 수지와의 계면접착특성)

  • Yong, Da Kyung;Choi, Han Na;Yang, Ji Woo;Lee, Seung Goo
    • Journal of Adhesion and Interface
    • /
    • v.13 no.1
    • /
    • pp.24-30
    • /
    • 2012
  • Morphological changes of polyarylate (PAR) fiber treated with formic acid and ultraviolet (UV) were observed by using a scanning electron microscope (SEM) and an atomic force microscope (AFM). The results were analysed by using root mean square (RMS) roughness. In addition, the chemical changes of surface was investigated using contact angle and the interfacial adhesive strength between PAR fiber and PEN (Polyethylene naphthalate) matrix was calculated using the Pull-out test results. As the acid treatment concentration and UV irradiation time increased, cracks and pores were produced on the PAR fiber surface. Due to the roughness increased, the contact angle was decreased. For this reason, RMS roughness of PAR fiber was increased and the interfacial adhesive strength between the PAR fiber and PEN matrix was improved. The increase of interfacial adhesive strength was responsible for the increase of surface area which have cracks and pores.

A study on parsimonious periodic autoregressive model (모수 절약 주기적 자기회귀 모형에 관한 연구)

  • Lee, Jiho;Seong, Byeongchan
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.1
    • /
    • pp.133-144
    • /
    • 2016
  • This paper proposes a parsimonious periodic autoregressive (PAR) model. The proposed model performance is evaluated through an analysis of Korean unemployment rate series that is compared with existing models. We exploit some common features among each seasonality and confirm it by LR test for the parsimonious PAR model in order to impose a parsimonious structure on the PAR model. We observe that the PAR model tends to be superior to existing seasonal time series models in mid- and long-term forecasts. The proposed parsimonious model significantly improves forecasting performance.

The Influences of Perceived Adequacy Resource and Locus of Control on the Stress from the Family Resource Management in Housewives (가정자원적정도지각과 통제소재가 주부의 가정자원관리 스트레스에 미치는 영향)

  • 정서린
    • Journal of Families and Better Life
    • /
    • v.15 no.2
    • /
    • pp.141-154
    • /
    • 1997
  • The purpose of this study was to investigate the influence of perceived adequacy resource(PAR) and locus of control on the stress from the family resources management in housewives. The subjects of this study were 474 married women who lived in apartment in Taegu, . A questionaire was used as survey method. Factor analysis and MANOVA were employed for data analysis and Scheffe test for post-hoc analysis, . The main findings were ; First the effect of PAR on the degree of the stress from the family resources management was not different according to locus of control. Second the stress from the family resource management was found to be significantly different according to PAR.

  • PDF

Testing and Self Calibration of RF Circuit using MEMS Switches

  • Kannan, Sukeshwar;Kim, Bruce;Noh, Seok-Ho;Park, Se-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.882-885
    • /
    • 2011
  • This paper presents testing and self-calibration of RF circuits using MEMS switches to identify process-related defects and out of specification circuits. We have developed a novel multi-tone dither test technique where the test stimulus is generated by modulating the RF carrier signal with a multi-tone signal generated using an Arbitrary Waveform Generator (AWG) with additive white Gaussian noise. This test stimulus is provided as input to the RF circuit and peak-to-average ratio (PAR) is measured at the output. For a faulty circuit, a significant difference is observed in the value of PAR as compared to a fault-free circuit. Simulation is performed for various circuit conditions such as fault-free as well as fault-induced and their corresponding PARs are stored in the look-up table. This testing and self-calibration technique is exhaustive and efficient for present-day communication systems.

  • PDF

Cost Reduction and Improving Profitability of Par Level Transfer System for Reagent Materials (정량보충제 도입에 따른 비용절감 및 수익성 증대 효과)

  • Vae, Suk Jin;Hwang, Sung Wan
    • Korea Journal of Hospital Management
    • /
    • v.17 no.4
    • /
    • pp.21-31
    • /
    • 2012
  • This is a case study of Gangnam S University Hospital applying a par level transfer system for reagent materials. The purpose of this study is evaluated on the cutting down on inventory expenses and medical service revenue in the point of resource based view. The data was acquired through the financial statement of Gangnam S Hospital for the fiscal year 2008, 2009, 2010 and 2011, and compared with the Korea health industry statistics index for hospital accounts based on the materials in Korea Health Industry Development Institute. The results of the study are as follows. Medical reagent materials expenditure cut down as 305 million won through 2009 fiscal year. Medical profits for the Gangnam S University hospital's income statement in 2011 show well over acquired 3.37 billion won through the enlarged diagnostic test numbers. In conclusion, Gangnam S University Hospital health statistics's index shows very high profits. The results of this study have some limitations in terms of generalization as only one hospital in Seoul. Further studies with relationship inventory performance and enlarged reagent materials are expected in this area.

  • PDF

Optimum actuator placement for damping of vibrations using the Prestress-Accumulation Release control approach

  • Poplawski, Blazej;Mikulowski, Grzegorz;Pisarski, Dominik;Wiszowaty, Rafal;Jankowski, Lukasz
    • Smart Structures and Systems
    • /
    • v.24 no.1
    • /
    • pp.27-35
    • /
    • 2019
  • This paper proposes a quantitative criterion for optimization of actuator placement for the Prestress-Accumulation Release (PAR) strategy of mitigation of vibrations. The PAR strategy is a recently developed semi-active control approach that relies on controlled redistribution of vibration energy into high-order modes, which are high-frequency and thus effectively dissipated by means of the natural mechanisms of material damping. The energy transfer is achieved by a controlled temporary removal of selected structural constraints. This paper considers a short-time decoupling of rotational degrees of freedom in a frame node so that the bending moments temporarily cease to be transferred between the involved beams. We propose and test a quantitative criterion for placement of such actuators. The criterion is based on local modal strain energy that can be released into high-order modes. The numerical time complexity is linear with respect to the number of actuators and potential placements, which facilitates quick analysis in case of large structures.