• Title/Summary/Keyword: P loading

Search Result 1,472, Processing Time 0.028 seconds

Treatment of Piggery Wastewater by Anoxic-Oxic Biofilm Process (준혐기-호기 생물막 공정을 이용한 돈사폐수 처리)

  • 임재명;한동준
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 1997
  • This research aims to develop biofilm process for the nutrient removal of piggery wastewater. The developed process is the four stage anoxic-oxic biofilm process with recirculation of the final effluent. In summery, the results are as follows: 1. Nitrification in the piggery wastewater built up nitrite because of the high strength ammonia nitrogen. The nitrification of nitrobacter by free ammonia was inhibited in the total ammonia nitrogen loading rate with more than 0.2 kgNH$_{3}$-N/m$^{3}$·d. 2. The maximal total ammonia nitrogen removal rate was obtained at 22$\circ $C and without being affected by the loading rate. But total oxidized nitrogen production rate was largely affected by loading rate. 3. Autooxidation by the organic limit was a cause of the phosphorus release in the aerobic biofilm process. But the phosphorus removal rate was 90 percent less than the influent phosphorus volumetric loading rate of above 0.1 kgP/m$^{3}$·d. Therefore, the phosphorus removal necessarily accompanied the influent loading rate. 4. On the anoxic-oxic BF process, the total average COD mass balance was approximately 67.6 percent. Under this condition, the COD mass removal showed that the cell synthesis and metabolism in aerobic reactor was 42.8 percent and that the denitrification in anoxic reactor was 10.7 percent, respectively.

  • PDF

A Study on the Calculation Scheme of Extreme Loading Point and Nose Curves using Modified N-R and Continuation Method (수정N-R법과 연속음형법을 이용한 임계부하점 및 Nose Curve 산정기법 연구)

  • Yu, In-Keun
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.7
    • /
    • pp.712-722
    • /
    • 1992
  • Several voltage instability/collapse problems that have occurred in the electric utility industry worldwide have gained the attention of engineers and researchers of electric power systems. This paper proposes an effective calculation scheme of the extreme loading point and nose curves(P-V curves) using modified Newton-Raphson(N-R) load flow method and the Continuation Method. This method provides detail and visual information of the power system voltage profile and operating margin ro operators and planners. In this paper, a modified load flow claculation method for ill-conditioned power systems is introduced for the purpose of seeking more precise load flow solutions and nose curves, and the Continuation Method is also used as a part of the solution algorithm for the calculation of extreme loading point and nose curves. The conventional polar coordinate based N-R load flow program is modified to avoid numerical difficulties caused by the singularity of the Jacobian matrix occuring in the vicinity of extreme loading point of heavily loaded systems. Application results of the proposed method to Klos-Kerner 11-bus system and modified IEE-30-bus system are presented to assure the usefulness of the approach.

  • PDF

Fatigue Crack Closure and Propagation Behavior Under Mixed-Mode Loading Observed by the Direct Measuring Method (직접측정법을 이용한 혼합모드 하중 하에서 피로균열의 닫힘과 전파거동)

  • Song Sam Hong;Seo Ki Jeong;Lee Jeong Moo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.152-158
    • /
    • 2005
  • The stress conditions acting on the practical structure are complex, and thus most cracks existing in the practical structures are under mixed-mode loading conditions. The effect of shear load component of mixed-mode loading acts more greatly in the stage of crack initiation and initial propagation than crack propagation stage. Hence, research on the behavior in the stage of crack initiation and initial propagation need to be examined in order to evaluate behavior of mixed-mode fatigue cracks. In this study, the crack tip displacement(CTD) was measured by using the direct measuring method(DMM). We examined the behavior at crack tip by determining crack opening load$(P_{op})$. From the test results, the propagation behavior of mixed-mode fatigue cracks was evaluated by considering mixed-mode crack closure. Also, we examined the characteristic of crack propagation under mixed-mode loading with crack propagation direction.

Flexural behaviour of GFRP reinforced concrete beams under cyclic loading

  • Murthy, A. Ramachandra;Gandhi, P.;Pukazhendhi, D.M.;Samuel, F. Giftson;Vishnuvardhan, S.
    • Structural Engineering and Mechanics
    • /
    • v.84 no.3
    • /
    • pp.361-373
    • /
    • 2022
  • This paper examines the flexural performance of concrete beams reinforced with glass fibre-reinforced polymer (GFRP) bars under fatigue loading. Experiments were carried out on concrete beams of size 1500×200×100 mm reinforced with 10 mm and 13 mm diameter GFRP bars under fatigue loading. Experimental investigations revealed that fatigue loading affects both strength and serviceability properties of GFRP reinforced concrete. Experimental results indicated that (i) the concrete beams experienced increase in deflection with increase in number of cycles and failed suddenly due to snapping of rebars and (ii) the fatigue life of concrete beams drastically decreased with increase in stress level. Analytical model presented a procedure for predicting the deflection of concrete beams reinforced with GFRP bars under cyclic loading. Deflection of concrete beams was computed by considering the aspects such as stiffness degradation, force equilibrium equations and effective moment of inertia. Nonlinear finite element (FE) analysis was performed on concrete beams reinforced with GFRP bars. Appropriate constitutive relationships for concrete and GFRP bars were considered in the numerical modelling. Concrete non linearity has been accounted through concrete damage plasticity model available in ABAQUS. Deflection versus number of cycles obtained experimentally for various beams was compared with the analytical and numerical predictions. It was observed that the predicted values are comparable (less than 20% difference) with the corresponding experimental observations.

Investigation of damaged formwork timber beam retrofitting with anchoraged CFRP strip under different loading

  • Abdullah TURER;Ozgur ANIL;Abdulkadir CEVIK;R. Tugrul Erdem
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.689-703
    • /
    • 2024
  • Construction of high-rise structures, formwork systems that can be installed quickly, resistant to external loads, can be used more than once, have become a necessity. Timber and composite timber materials are preferred in the formation of such formwork systems due to their durability, ease of assembly, light weight and easy to use more than one time. Formwork beams are the most commonly used structural component in the formation of such formwork systems, and these beams can be damaged for different reasons during their lifetime. In this study, H20 top P type timber formwork beams with 1800 and 2450 mm length which is among the products of DOKA(c) company is damaged under the effect of static loading up to a high load level of 85% of the maximum ultimate capacity and after being retrofitted using anchored CFRP strips, performance and behavior of the beams under the influence of various loading types such as static, fatigue and impact are investigated experimentally. Two different lengths of retrofitted timber formwork beams were tested by applying monotonic static, fatigue and impact loading and comments were made about the effects of the retrofit method on performance under different loading types.

Experiment of Reactive Media Selection for the Permeable Reactive Barrier Treating Groundwater contaminated by Acid Mine Drainage (산성광산배수로 오염된 지하수 정화용 투수성 반응벽체 반응매질 선정 기초실험)

  • Ji Sang Woo;Cheong Young Wook
    • Economic and Environmental Geology
    • /
    • v.38 no.3 s.172
    • /
    • pp.237-245
    • /
    • 2005
  • The batch tests were performed to evaluate the applicability of the permeable reactive barrier (PRB) to in-situ treatment of groundwater with high concentration of heavy metals. The lead\chates used in this study were collected from waste rock dump of the Imgy mine, and have a low pH and high metal concentration. The acidity loading was 65kg as $CaCO_3/day$, metal loading of Fe+Al+Mn was 11.6kg/day. This type of water could be treated with biological-mediated sulfate reduction using the organic carbon mixture as a reactive media. The batch tests were carried out with five mixtures that were composed with different mixing ratios of mushroom compost, pine-tree bark, and limestone cheep. Results indicated that the PRB could reduce the acidity loading $CaCO_3/day$ to 12.3kg and reduce the metal loading to 3.3kg/day. Considering about the low pH and high metal loading, the contaminated water may be ameliorated by passing it through the buffering PRB composed with inorganic carbonate materials and then through the PRB composed with the organic carbon mixture which can induce sulfate reduction.

Seismic response of foundation-mat structure subjected to local uplift

  • El Abbas, Nadia;Khamlichi, Abdellatif;Bezzazi, Mohammed
    • Coupled systems mechanics
    • /
    • v.5 no.4
    • /
    • pp.285-304
    • /
    • 2016
  • The effects of large rotations and p-delta on the dynamic response of a structure subjected to seismic loading and local uplift of its foundation were analyzed in this work. The structure was modeled by an equivalent flexible mat mounted on a rigid foundation that is supported either by a Winkler soil type or a rigid soil. The equations of motion of the system were derived by taking into account the equilibrium of the coupled foundation-mat system where the structure was idealized as a single-degree-of-freedom. The obtained nonlinear coupled system of ordinary differential equations was integrated by using an adequate numerical scheme. A parametric study was performed then in order to evaluate the maximum response of the system as function of the intensity of the earthquake, the slenderness of the structure, the ratio of the mass of the foundation to the mass of the structure. Three cases were considered: (i) local uplift of foundation under large rotation with the p-delta effect, (ii) local uplift of foundation under large rotation without including the p-delta effect, (iii) local uplift of foundation under small rotation. It was found that, in the considered ranges of parameters and for moderate earthquakes, assuming small rotation of foundation under seismic loading can yield more adverse structural response, while the p-delta effect has almost no effect.

Comparison of Clopidogrel versus Cilostazol in Coronary Artery Stenting (관상동맥 스텐트 삽입술 후 Clopidogrel과 Cilostazol의 비교)

  • Song, In-Sook;Choi, Seung-Ki;Oh, Jung-Mi
    • Korean Journal of Clinical Pharmacy
    • /
    • v.15 no.2
    • /
    • pp.105-117
    • /
    • 2005
  • Following intracoronary stenting, antiplatelet therapy lead to greater protection from thrombotic complication. A few data are available about the effect of clopidogrel versus cilostazol, an antiplatelet commonly used after intracoronary stenting. To evaluate the efficacy and safety of clopidogrel plus aspirin compared with those of cilostazol plus aspirin in coronary stenting and to evaluate the efficacy of clopidogrel loading dose prior to coronary stealing in clopidogrel group. Data were retrospectively collected from medical charts of patients who had undergone coronary stenting and received either clopidogrel with or without loading 300 mg followed by 75 mg/d (n=58), or 200 mg/d cilostazol(n=72) for 1 year, between January 2000 and May 2002. All patients in both groups received aspirin 200 mg/d throughout the study. The primary endpoints at 7, 30, 180 and 365 days after stealing were the composite of death, Myocardial Infarction, stroke, angina, and revascularization in the intent to treat population and restenosis at follow up angiography. The secondary endpoints were the incidence of bleeding complications at 7, 30, and 365 days, and durg adverse effects at 365 days after stenting. At 180 and 365 days after stenting, the combined primary endpoints were significantly reduced in clopidogrel plus aspirin group (relative risk 0.39; 95% CI 0.17 to 0.92; p=0.021, RR 0.43; 95% CI 0.22 to 0.84; p=0.0085, respectively). However, the combined primary endpoints were not significantly different between the two groups at 7 and 30 days (p:1.00, p=0.79, respectively). Angiographic restenosis rate was 14.3% in clopidogrel plus aspirin uoup and 32.1% in cilostazol plus aspirin group (p=0.19). 300mg of clopidogrel loading dose did not significantly reduce the combined primary endpoints at 30 days after stenting (RR 0.14; 95% CI 0.01 to 2.65; p=0.23). The rate of bleeding complications and drug adverse effects were not different between the two groups. In patients undergoing intracoronary stenting, clopidogrel plus aspirin therapy is more beneficial than cilostazol plus aspirin in reducing major adverse cardiac events with similar rate of bleeding complication. A loading dose of clopidogrel did not lead to a statistically significant reduction in major adverse cardiac events.

  • PDF

A Numerical Analysis Study for Estimation of Ultimate Bearing Capacity and An Analysis of the High Capacity Bi-directional Pile Load Tests of the Large-diameter Drilled Shafts (대구경 현장타설말뚝의 대용량 양방향 말뚝재하시험 분석 및 극한지지력 추정을 위한 수치해석 연구)

  • Nam, Moonsuk;Kim, Sangil;Hong, Seokwoo;Hwang, Seongchun;Choi, Yongkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.10
    • /
    • pp.63-72
    • /
    • 2011
  • The high capacity bi-directional pile load test is an optimum pile load test method for high-rised buildings. Especially, a high pressure and double-acting bi-directional pile load testing, a special type of the high capacity bi-directional pile load test, is the most practical way to overcome limitations of loading capacities and constraints of field conditions, which was judged to be a very useful test method for requiring high loading capacities. Total of 2 high capacity bi-directional pile load tests(P-1 and P-2) were conducted in high-rised building sites in Korea. Based on the field load test results, the sufficiency ratio of loading capacities to design loads for P-1 and P-2 were 3.3 and 2.1, respectively. For P-2, the load test could not verify the design load if 1-directional loads applied slightly smaller than the actual applied load. Also, high capacity bi-directional pile load tests were difficult to determine an ultimate state of ground or piles, although the loads were applied until their maximum loads. Hence, finite element analyses were conducted to determine their ultimate states by calibrating and extrapolate with test results.

pH-Sensitive Release of Indomethacin from Curdlan Acetate Microspheres (Curdlan Acetate Microspheres를 이용한 Indomethacin의 pH 민감성 방출)

  • Lee Chang-Moon;Lee Young-Jin;Kim Hyung-Ju;Park Hee-Jung;Lee Ki-Young
    • KSBB Journal
    • /
    • v.20 no.1 s.90
    • /
    • pp.46-49
    • /
    • 2005
  • Curdlan, a natural $\beta-1,3-glucan,$ has been studied as drug carrier due to its unique properties including its thermal gelling characters. In this study, curdlan was chemically acetylated for pH-sensitive drug delivery. Curdlan acetate microspheres(CAMs) were prepared by the solvent evaporation method. The size of the CAMs was below $200{\mu}m.$ The drug loading efficiency of microspheres was approximately $58.44\%$. In the swelling test, the CAMs showed pH-sensitive behavior. The swelling capacity of microspheres at pH 7.4 was much greater than at pH 1.4. Also, release rate of indomethacin(IND) at pH 7.4 from the CAMs was faster than that at pH 1.4. Therefore the CAMs have potential for the controlled release of IND over an extended period of time.