• Title/Summary/Keyword: Ozone Lamp

Search Result 45, Processing Time 0.02 seconds

A Study of Characteristic of Oriental Herbal Medicine Storage System using Ozone Lamp (오존램프를 이용한 한약재 저장 장치의 특성 연구)

  • Woo, Sung-Hun;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.98-103
    • /
    • 2007
  • We made a oriental herbal medicine storage system and studied a preservation characteristic of oriental herbal medicine in this research. The lamp(OZ-Lamp) in a storage system is the low pressure ultraviolet lamp which radiates the sterilizing and ozonic rays. We made research ozone generation and electric discharge characteristic of a oriental herbal medicine storage system, which have radiation feature of ultraviolet rays of a short wavelength to be happened in the electric discharge. Also, we made research an ingredient and quality characteristic of oriental herbal medicine according to ozone treatment storage.

A Study on the Lamp Type Ozonizer (Lamp 형 오존발생기에 관한 연구)

  • 강천수;송현직;김상구;박원주;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.25-28
    • /
    • 1995
  • This paper describes ozone concenteration(O3con) and ozone generation(O3g) of lamp type ozo-nizer(O-Lamp)which be performed a role of lighting source and ozonizer. O=Lamp is consist of two low pressure mercury lamps. The important conclus-ions obtained from this paper are as follows, The more quality of supplied gas(Q) decrease, the higher O3con rise, The more quality of supplied gas(Q) increase, the higher O3g some rise. The Escherichia coli is reacted on ozone can be sterilized above 99[%]. Also, O-Lamp can confirmed possibility of appli-cation as lighting-source.

  • PDF

Measurement Technique of Ozone Density by Using UV Sensor System

  • Trung, Nguyen Huu;Van Men, Le;Van Hieu, Nguyen
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.80-86
    • /
    • 2015
  • There are many studies and products using a test paper impregnated with chemical solution can react with ozone. The color of a test paper can indicate the concentration of ozone. The purpose of this research is to design and manufacture a system using ultraviolet light source to measure the ozone density. This new technique is based on the characteristic of decomposition from ozone into oxygen under ultraviolet light. We used two sources of ultraviolet light including UV lamp and UVLED to determine the decomposition of ozone. This system is built with the electronic components, sensors and sealed pump tube to measure the ozone density in units of $g/cm^3$,ppm,ppb. In this paper,, we present some initial results of measuring the ozone density from ozone generator after completing inspection for safety.

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

A Study on the Trial Manufacture and Characteristics of Lamp Type Ozonizer (Lamp 형 오존발생기의 시작 및 특성에 관한 연구)

  • Kim, Sang-Ku;Song, Hyun-Jig;Kang, Cheon-Su;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.6
    • /
    • pp.62-72
    • /
    • 1996
  • In this paper, ozonizer using U-type lamp(Olamp) has been designed and manufactured, which can perform a role of lighting source and ozonizer by using photo and chemical methods. The discharge, spectrum, illuminance, ozone concentration, ozone generation, ozone yield and sterilization characteristics of Olamp have been studied. The important conclusions obtained from this paper can be summa'||'&'||'not;rized as follows. As a result of spectrum characteristics for Olamp, ultraviolet ray of a short wave'||'&'||'not;lengths and a visible ray are radiated. The illuminance of Olamp was found to be useful for "color distinctive and intermittent works in the dark working spaces" in accordance with KS A 3011. The ozone concentration of gaseous phase is inversely proportional to quality of supplied gas. Also, ozone conce tration and generation of gaseous phase are rised more commercial oxygen gas than those trial air gas for constant quality of supplied gas. Ozone generation and ozone yield of gaseous phase are proportion'||'&'||'not;al to ozone concentration of gaseous phase. The characteristics of liquid ozone concentration at distilled water are proportional to circulating velocity of fermentation chamber and ozone concentration of gas'||'&'||'not;eous phase. As a result, the sterilization characteristics of Escherichia coli have been obtained more than 97[ % J.

  • PDF

A Study on the Lamp Type Ozonizer (Lamp 형 오존발생기에 관한 연구)

  • Kang, Cheon-Su;Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1407-1409
    • /
    • 1995
  • This paper describes ozone concenteration($O_{3con}$), ozone generation($O_{3g}$) and ozone yield($O_{3Y}$) of lamp type ozonizer which be performed a role of lighting source and ozonizer. OLamp is consist of two of low pressure mercury lamps. The important conclusions obtained from this paper are as follows, The more quality of supplied gas(Q) decrease, the higher $O_{3con}$ rise. The more quality of supplied gas(Q) increase, the higher $O_{3g}$ some rise. When supplied oxygen 10[l/min] obtained 4,010[mg/kwh] $O_{3Y}$. The Echerichia coli which is reacted on ozone can be sterilized about 95[%].

  • PDF

A study on the characteristics of ozone generation using photochemical reaction lamp (광화학 램프를 이용한 오존발생 특성 연구)

  • Woo, Sung-Hun;Lee, Sang-Keun;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.321-323
    • /
    • 2004
  • In this paper, We have designed and manufactured a photochemical reaction lamp type ozonizer system which was performed a role of preservation of oriental herbal medicine. This paper describes preliminary discussions on the characteristics of ozone concentration and discharge parameters according to number of turn-on lamp.

  • PDF

A study on the Characteristics of Ozone Application Using Photochemical Reaction Lamp (광화학 램프를 이용한 오존응용특성 연구)

  • Woo, Sung-Hun;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.423-425
    • /
    • 2008
  • In this paper, We have designed and manufactured a photochemical reaction lamp type ozonizer system which was applied to keep quality of herb medicines during storage. We used photochemical reaction lamp in a storage system, and investigated the sterilization characteristic. Also, we made research an ingredient and quality characteristic of herb medicines according to ozone storage.

  • PDF

The Characteristics of the Discharge Lamp Type Ozonizer using Pulse Power Source for Carnation Productivity Improvement (카네이션 생산성 향상을 위한 펄스 전원을 활용한 방전관형 오존발생기의 특성)

  • Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.68-74
    • /
    • 2007
  • For carnation productivity improvement, compact-low cost discharge lamp type ozonizer using pulse power source is designed and manufactured. This paper describes the discharge characteristics and the ozone generation characteristics with variation of the output voltage of pulse power source, the quantity of flowing air and the operating number of ozonizer. The important conclusions are as follows. The discharge voltage and current values are proportional to the output voltage of pulse power source. The ozone concentration and generation are proportional to the output voltage of pulse power source and the number of ozonizer. The maximum value of the ozone concentration and generation of the discharge lamp type ozonizer can be obtained 890[ppm] and 59.7[mg/h] respectively. In the carnation productivity house, when the discharge lamp type ozonizer is used the carnation is good quality in the uniformity of the carnation stalk thickness and increased the productivity through improvement of the air and the soil.

Application of Photocatalytic Degradation for Efficient Treatment of Organic Matter in Landfill Leachate in Jeju Island (제주도 매립장 침출수 중 유기물의 효율적 처리를 위한 광촉매 분해 반응의 응용)

  • Lee, Chang-Han;Lee, Taek-Kwan;Cho, Eun-Il;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.31 no.8
    • /
    • pp.677-689
    • /
    • 2022
  • In order to photocatalytically treat organic matter (CODCr) and chromaticity effectively, chemical coagulation and sedimentation processes were employed as a pretreatment of the leachate produced from landfill in Jeju Island. This was performed using FeCl3·6H2O as a coagulant. For the treated leachate, UV/TiO2 and UV/TiO2/H2O2 systems were investigated, using 4 types of UV lamps, including an ozone lamp (24 W), TiO2 as a photocatalyst, and/or H2O2 as an initiator or inhibitor for photocatalytic degradation. In the chemical coagulation and sedimentation process using FeCl3·6H2O, optimum removal was achieved with an initial pH of 6, and a coagulant dosage of 2.0 g/L, culminating in the removal of 40% CODCr and 81% chromaticity. For the UV/TiO2 system utilizing an ozone lamp and 3 g/L of TiO2, the optimum condition was obtained at pH 5. However, the treated CODCr and chromaticity did not meet the emission standards (CODCr: 400 mg/L, chromaticity: 200 degrees) in a clean area. However, for a UV/TiO2/H2O2 system using 1.54 g/L of H2O2 in addition to the above optimum UV/TiO2 system, the results were 395 mg/L and 160 degrees, respectively, which were within the emission standard limits. The effect of the UV lamp on the removal of CODCr, and chromaticity of the leachate decreased in the order of ozone (24 W) lamp > 254 nm (24 W) lamp > ozone (14 W) lamp > 254 nm (14 W) lamp. Only CODCr and chromaticity treated with the ozone (24 W) lamp met the emission standards.