• 제목/요약/키워드: Oxidation-resistance

검색결과 833건 처리시간 0.021초

베어링강의 미끄럼 마모거동에 미치는 Tempering 경도의 영향 (Effects of Hardness on Sliding Wear Behavior of Tempered Bearing Steel)

  • 이한영
    • Tribology and Lubricants
    • /
    • 제29권6호
    • /
    • pp.360-365
    • /
    • 2013
  • In this study, sliding wear tests were conducted to investigate the effects of tempered hardness on the sliding wear behavior of bearing steel. At a sliding speed of 0.3 m/s, the wear resistance of bearing steel with a tempered hardness of HRC 54 was superior to that with HRC 62. It was found that bearing steel with HRC 54 showed a strong tendency for the occurrence of oxidation wear at that speed, compared to that with HRC 62. This would be due to the troostitic structure of bearing steel with HRC 54, which is highly susceptible to corrosion. In this context, it is considered that sliding wear behavior could be affected by the corrosion resistance of the material.

石炭의 黑鉛性에 關한 硏究 (第2報) (On the Graphitic Properties of Korean Anthracite (II) X-ray Diffraction Method as an Estimation of the Graphitic Properties of Anthracite)

  • 오신섭;이석원;이창무
    • 대한화학회지
    • /
    • 제7권2호
    • /
    • pp.182-185
    • /
    • 1963
  • In the previous paper of the series of researches on the graphitic properties of anthracites, authors have already reported the results on the electrical specific resistance measurements for Korean anthracites in order to develope a simple methods which differentiate graphite from anthracite. In this paper, the X-ray diffraction method and oxidation have been applied and compared with the results which were obtained by the specific resistance measurements in the previous paper. It has been confirmed that there is a parallel relation between the value of specific resistance measurement and height of hexagonal peak by X-ray diffraction, but the color reaction due to graphitic acid by oxidation does not show any definite critical points between graphite and anthracite.

  • PDF

MgO와 Al의 테르밋 반응생성물이 첨가된 MgO-C계 내화재료의 용손 기구 (Wear Mechanism of MgO-C Refractory with Thermite Reaction Products of MgO and Al)

  • 최태현;전병세
    • 한국세라믹학회지
    • /
    • 제33권7호
    • /
    • pp.832-838
    • /
    • 1996
  • Thermite reaction products of MgO and Al were added to MgO-C refractory to improve the properties of corrosion against the attack of slag, oxidation and mechanical spalling. Corrosion rate of MgO-C-MgAl2O4 spinel refractory at the ratio of 3.3(CaO/SiO2) slag was smaller than that of MgO-C and MgO-C-Al refractory. The excellent corrosion resistance of the MgO-C-MgAl2O4 spinel refractory against the slag attack was appeared by Al and MgAl2O4 spinel with high melting point and corrosion resistance and the high thermal conductivity and low thermal expansion of AIN. Hot M.O.R at 140$0^{\circ}C$ and the resistance of oxidation weight loss at 90$0^{\circ}C$ were 210kg/cm2 and -12% respectively.

  • PDF

고춧가루 섭취가 운동후초과산소섭취량에 미치는 영향 (Effect of red-pepper ingestion on excess post-exercise oxygen consumption in young women)

  • 황혜정;서혜정;임기원
    • 운동영양학회지
    • /
    • 제14권2호
    • /
    • pp.87-93
    • /
    • 2010
  • PURPOSE. The purpose of this study was to investigate the effect of red-pepper ingestion on excess post-exercise oxygen consumption in young women. METHODS. The six female college students involved in this experiment. The subjects participated in two trials, standard meal (650 kcal) and standard meal +10 g red-pepper with 200 ml water. After the subjects allowed to have rest for 60 min, exercised by resistance program for 40 minutes. RESULTS. The excess post-exercise oxygen consumption (EPOC) was not affected by the red-pepper ingestion. However, post-exercise fat oxidation and plasma free fatty acid levels were higher in red-pepper trial than in control trial. CONCLUSION. Therefore, red-pepper ingestion before resistance exercise might be improve body fat reduction.

The Characteristic Study of Plasma Electrolytic Oxidation in AZ31B Magnesium Alloy

  • Yu, Jae-Yong;Choi, Soon-Don;Yu, Jae-In;Yun, Jae-Gon;Ko, Hoon;Jung, Yeon-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1746-1751
    • /
    • 2015
  • In this study low voltage Plasma Electrolytic Oxidation (PEO) was utilized to eliminate high voltage PEO drawbacks such as high cost, dimensional deformation and porosity. Low voltage PEO produces a thin coating which causes low corrosion resistance. In order to solve such problem, 0.1~0.6M pyrophosphates were added in a bath containing 1.4M NaOH, and 0.35M Na2SiO3. 70 V PEO was conducted at 25℃ for 3 minutes. Chemical composition, morphology and corrosion resistance of the anodized coating were analyzed. The anodized film was composed of MgO, Mg2SiO4, and Mg2O7P2. The morphology of film showed appropriately dense structure and low porosity in the anodized layers. It is found that low voltage Plasma Electrolytic Oxidation in cooperation with phosphating treatment can provide a good corrosion protection for the AZ31B magnesium alloy.

CrAlN과 CrZrN의 산화 (Oxidation of CrAlN and CrZrN Films)

  • 김민정;김슬기;이상율;이동복
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2011년도 춘계학술대회 및 Fine pattern PCB 표면 처리 기술 워크샵
    • /
    • pp.33-35
    • /
    • 2011
  • Films of CrAlN and CrZrN were deposited on a steel substrate by closed field unbalanced magnetron sputtering, and their oxidation behaviors were investigated. CrAlN films consisted of dense, polycrystalline CrN and AlN fine columns. The formed oxides consisted primarily of crystalline $Cr_2O_3$ incorporated with $Al_2O_3$. The oxide layers were thin and compact so as to make CrAlN films more protective than CrN films. In case of CrZrN films, Zr atoms were dissolved in the CrN phase. Zr atoms advantageously refined the columnar structure, reduced the surface roughness, and increased the micro-hardness. However, the addition of Zr did not increased oxidation resistance, mainly because Zr was not a protective element. All the deposited films displayed relatively good oxidation resistance, owing to the formation of the highly protective $Cr_2O_3$ on their surface. The $Cr_{40}Zr_9N$ and $Cr_{31}Zr_{16}N$ films oxidized to $Cr_2O_3$ as the major phase and ${\alpha}-ZrO_2$ as the minor one, whereas the CrN film oxidized to $Cr_2O_3$.

  • PDF

Fe-Al과 Fe-Cr계 합금의 내 산화성에 미치는 Al과 Cr의 영향 (Effect of Al and Cr on Oxidation of Fe-Al and Fe-Cr Alloys)

  • 김태완;조승훈;고인용;도정만;윤진국;손인진
    • 대한금속재료학회지
    • /
    • 제48권11호
    • /
    • pp.981-988
    • /
    • 2010
  • The effects of Cr and Al contents in Fe-Al and Fe-Cr alloys on oxidation resistance, hardness, and the thermal expansion coefficient were investigated. Fe-Al and Fe-Cr alloys above 10wt.%Al and 20wt.%Cr contents have a high oxidation resistance. The hardness of the Fe-Al and Fe-Cr alloys increased with an increase in Al and Cr contents due to solid solution or formation of an intermetallic compound. The coefficients of thermal expansion of the Fe-Al alloys were higher than those of the Fe-Cr alloys because the coefficient of thermal expansion of Al was higher than that of Fe and Cr.

스테인리스 스틸의 표면 산화피막 성장과 내부식성 상관관계 (Correlation of Surface Oxide Film Growth with Corrosion Resistance of Stainless Steel)

  • 박영주;유진석;심성구;정찬영
    • Corrosion Science and Technology
    • /
    • 제20권3호
    • /
    • pp.152-157
    • /
    • 2021
  • Stainless steel is a metal that does not generate rust. Due to its excellent workability, economic feasibility, and corrosion resistance, it is used in various industrial fields such as ships, piping, nuclear power, and machinery. However, stainless steel is vulnerable to corrosion in harsh environments. To solve this problem, its corrosion resistance could be improved by electrochemically forming an anodized film on its surface. In this study, 316L stainless steel was anodized at room temperature with ethylene glycol-based 0.1 M NH4F and 0.1M H2O electrolyte to adjust the thickness of the oxide film using different anodic oxidation voltages (30 V, 50 V, and 70 V) with time control. The anodic oxidation experiment was performed by increasing the time from 1 hour to 7 hours at 2-hour intervals. Corrosion resistance according to the thickness of the anodic oxide film was observed. Electrochemical corrosion behavior of oxide films was investigated through polarization experiments.

수소화물에 의한 Zr 합금의 고온산화 가속효과 (Hydrogen Effect on the Oxidation of Zr-Alloy Claddings under High Temperature)

  • 정윤목;하성우;박광헌
    • 한국표면공학회지
    • /
    • 제49권4호
    • /
    • pp.389-394
    • /
    • 2016
  • The operation method of nuclear power plants is currently changing to high burn-up and long period that can enhance economics and efficiency of the plant. Since nuclear plant operation environment has been becoming severe, the amount of absorbed hydrogen also has increased. Absorbed hydrogen can be fatal securing safety of nuclear fuel cladding in case of Loss of Coolant Accidents(LOCA). In order to examine the impact of hydride on high-temperature oxidation, high-temperature oxidation experiment was performed on normal Zry-4 cladding and on Zry-4 cladding where hydrogen is charged in air pressure steam atmosphere under the $950^{\circ}C$ and $1000^{\circ}C$. According to the results, while oxidation acceleration due to charged hydrogen was not observed prior to breakaway oxidation creation, oxidation began to accelerate in cladding where hydrogens charged as soon as the breakaway oxidation started. If so much hydrogen are charged in the cladding, equiaxial monoclinic phase to unstable of stress is formed and it is presumed that oxidation is accelerated because nearby stress caused a crack in equiaxial phase, and that makes corrosion resistance decline sharply.

ICP 스퍼터를 이용한 TMR 소자 제작에서 절연막의 플라즈마 산화시간에 따른 미세구조 및 자기적 특성 변화 (Effect of plasma oxidation time on TMR devices prepared by a ICP sputter)

  • 이영민;송오성
    • 한국재료학회지
    • /
    • 제11권10호
    • /
    • pp.900-906
    • /
    • 2001
  • We prepared tunnel magnetoresistance(TMR) devices of Ta($50\AA$)/NiFe($50\AA$)/IrMn(150$\AA$)/CoFe($50\AA$)/Al ($13\AA$)-O/CoFe($40\AA$)/NiFe($400\AA$)/Ta(50$\AA$) structure which has 100$\times$100 $\mu\textrm{m}^2$ junction area on $2.5\Times2.5 cm^{2}$ $Si/SiO_2$ ($1000\AA$) substrates by a inductively coupled plasma(ICP) magnetron sputter. We fabricated the insulating layer using a ICP plasma oxidation method by varying oxidation time from 80 sec to 360 sec, and measured resistances and magnetoresistance(MR) ratios of TMR devices. We used a high resolution transmission electron microscope(HRTEM) to investigate microstructural evolution of insulating layer. The average resistance of devices increased from 16.38 $\Omega$ to 1018 $\Omega$ while MR ratio decreased from 30.31 %(25.18 %) to 15.01 %(14.97 %) as oxidation time increased from 80 sec to 360 sec. The values in brackets are calculated values considering geometry effect. By comparing cross-sectional TEM images of 220 sec and 360 sec-oxidation time, we found that insulating layer of 360 sec-oxidized was 30 % and 40% greater than that of 150 sec-oxidized in thickness and thickness variation, respectively. Therefore, we assumed that increase of thickness variation with oxidation time is major reason of MR decrease. The resistance of 80 sec-oxidized specimen was 160 k$\Omega$$\mu\textrm{m}^2$ which is appropriate for industrial needs of magnetic random access memory(MRAM) application.

  • PDF