• 제목/요약/키워드: Overbridge

검색결과 4건 처리시간 0.018초

전기철도 터널 및 고가 구조물의 차폐계수 산정에 대한 연구 (A Study on the Determination of the Screening Factors for the Tunnel and the Overbridge of the Electric Railway)

  • 최경;이향범;김형석;김학철
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1249-1256
    • /
    • 2018
  • For the screening factor of the tunnel and overbridge structure in the electrified railway, the ITU-T regulation denotes only a theoretical estimation method, and the actual numeric values are notified differently by the official announcement of each nations. In this study, the factors which can affect the screening factor are investigated and analysed by FEM and a suitable calculation method based on multi-conductor line theory for the current pre-estimation formula for the induction noise voltage in the national notice is presented. The case studies are performed using the real data of the tunnel and the overbridge of the electrified railway, and a satisfactory formula for the determining of screening factor is derived.

철도용 고효율 친환경 경량방음터널 기술개발 (A Development of the Light Weight Noise Tunnel on a High Degree of Efficiency and Environmentally Friendly for Railway)

  • 손정곤;박광현;류래언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.487-490
    • /
    • 2014
  • These Days a lot of Noise Complaints in vicinity of Railway has been more increase than before. Almost 1/3 Residences who lives in Railway side are Exposure to Noise Pollution. Since the Apartment Buildings around Railway are getting more higher, so those of the Noise Barrier are not best solution anymore. We are going to make a New Plane with the state of the art technology for Railway Noise Abatement Control. Our Goal are focus on a development of Light Weight Noise Tunnel designed by new absorption mat'l and tunnel Stucture on the Overbridge and Viaduct of existing Railway. New Noise Tunnel will be reducing their weight more than 30% against Road Traffic One and also 10dB(A) Noise Reduction against Noise Barrier.

  • PDF

국내최장 고속철도 정지고가(L=9.3km) 교량형식 개발 및 설계 - 35m PSM PSC Box교, 80m 3경간 Arch교, 국내최초 ED교 - (The Planning and Design of Jeong-Ji High Speed Railway Bridge)

  • 장인호;박경호;박종화;김영남;김선필
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1691-1696
    • /
    • 2010
  • Jeong-Ji overbridge is designed to be 9.3km long, the longest for a high speed railway bridge ever constructed in Korea. This bridge is constituted of three types of structure. Standard type bridge is 35m PSC Box bridge which will be constructed by Precast Span Method. To cross the Cheonan Nonsan Expressway, 80m three-span steel arch bridge is designed to avoid rail expansion joint. Finally, Extradosed bridge is planned for high speed railway bridge for the first time in Korea based on originative and advanced design techniques. It is expected that this will contribute to the development of national technology for long-span high speed railway bridges.

  • PDF

지하철 연도변의 소음 조사 (A Field Survey of Noise Associated with Subway Train Passage)

  • 손정곤
    • 화약ㆍ발파
    • /
    • 제11권2호
    • /
    • pp.60-68
    • /
    • 1993
  • 서울지하철 제1, 2, 3, 4호선의 운행에 따른 소음 및 진동 발생은 인접 주거지역 주민들에게 공해 문제를 야기시켜 각종의 피해를 유발하고 있는 실정이다 그러나 현재 그 피해의 범위를 객관적으로 밝힐 수 있는 자료나지침이 없기 때문에 적절한 대책을 강구할 수가 없다. 따라서 본 조사를 통해 밝혀진 소음자료를 토대로 서울지하철 제1기 지상간의 지하철 차륜 통 과시 방출되는 소음레벨의 거리 별 분포 및 방출특성 그리고 각 노선별 비교 등과, 또 지하철 소음의 평가기준 및 평가방법과 현재 실용 가능한 방지대책을 제시하여 지하철 소음문제의 -반적인 처리지침으로 활용코져 한다. 본 조사 결과 제1호선 및 3호선은 소음레벨이 60dB(A) 미만으로 문제가 없고 소음공해 문제노선은 2호선 및 4호선의 일부 지상노출 구간으로 밝혀졌다. 이들 지역의 피선범위는 2호선의 경우 노선중심에서 50m 이내이고, 4호선의 경우 25m 이내로 이들 지점에서 각각 70dB(A)의 소음도를 기록하고 있다. 그리고 주민의 피해 호소율과 소음도 및 분포거리의 관계는 다음과 같이 밝혀졌다. 즉 80dB(A) 이상에서 강력한 집단민원이 발생하였고, 70-80dB(A)에서 간헐적인 피해호소를 하고 있었으며, 이들 값의 분포범위는 전자의 경우 고가구간에서 25m이내 철교구간에서 12.5m이내 그리고 철교 양구간에서 약 l00m이내이고, 후자의 경우 고가, 옹벽(U-Type) 및 철교구간에서 각각 50m이내이고, 철교량의 경우만 280m이내를 보이고 있다. 상기의 조사결과로부터 서울지하철의 일반적인 소음현황을 파악할 수 있어 지하철소음의 문제점을 개선하는데 필요한 자료로 활용할 수 있을 것으로 사료된다.

  • PDF