• 제목/요약/키워드: Outdoor PM10

검색결과 197건 처리시간 0.05초

낮은 증발온도에서 운전되는 가변속 롤러형 베인 압축기의 성능특성에 관한 분석 (Analysis on the performance characteristics of a variable-speed, roller-type vane compressor operating at low evaporating temperature)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.193-204
    • /
    • 1999
  • Performance of a variable-speed, roller-type vane compressor was evaluated at low evaporating temperature. First, an experimental investigation was conducted to examine the performance variation as functions of both outdoor temperature and rotating speed. For this purpose, a typical heat pump was implemented as a test apparatus to measure mass flow rate and power input. Secondly, computational investigations corresponding to the heat pump test conditions were performed to predict compressor performance using ORNL Map-Based compressor model. Results obtained from the heat-pump experiments showed that both mass flow rate and power consumption were sensitively dependent on both evaporating temperature and compressor speed as was predicted from the computational results. From the comparisons of both experimental and computational results, it was well recognized that the ORNL model was subjected to larger error in the accuracy of prediction as outdoor temperature decreased. When the outdoor temperature was above $-5^{\cire}C$, errors of predicted values corresponding to both mass flow rate and power consumption were estimated as $\pm$10% and $\pm$ 15%, respectively. Finally, it is suggested that the ORNL model needs to be re-evaluated if compressor map data tested below $-5^{\cire}C$(in evaporating temperature) are available.

  • PDF

실내·외 실시간 모니터링을 활용한 폼알데하이드 및 미세먼지(PM10, PM2.5)의 거주시간별 노출 및 위해도 평가 (Assessment of Exposure to and Risk of Formaldehyde and Particulate Matter (PM10 and PM2.5) by Time Activity Applying Real-Time Indoor and Outdoor Monitoring)

  • 윤단기;남궁선주;공혜관;홍형진;임희빈;박시현;이혜원;이정섭;이철민
    • 한국환경보건학회지
    • /
    • 제45권6호
    • /
    • pp.646-657
    • /
    • 2019
  • Objectives: The purpose of this study was to suggest methods to investigate continuous monitoring of concentration levels and assess the exposure of individuals considering the actual time activity of residents for formaldehyde and particulate matter (PM10, PM2.5) in the indoor and outdoor air of a house, assess the health risks of children and adults based on the results of the exposure assessment, and provide basic data on studies for assessing exposure and health risks in Korea in the future. Methods: The concentration levels of formaldehyde and particulate matter were measured in a family home in Gyeonggi-do Province from April 25 to July 31, 2019, using electrochemical sensors (formaldehyde) and light scattering sensors (PM10, PM2.5). Risk assessment by the duration of exposure by time activity was performed by dividing between weekdays and weekends, and indoors and outdoors. Results: The greatest level of carcinogenic risk from inhaling formaldehyde was indoors during the weekdays for both children and adults. For children, the risk was at 7.5 per approximately 10,000 people, and for adults, the risk was at 4.1 per approximately 10,000 people. PM10 and PM2.5 also showed the greatest values indoors during the weekdays, with children at 1.7 people and 1.4 per approximately 100 people, respectively, and adults at 8.2 per approximately 1,000 and 1.8 per approximately 100 people, respectively. Conclusions: The risks of formaldehyde, PM10 and PM2.5 were shown to be high indoors. Therefore, consideration of exposure assesment for each indoor pollutant and management of indoor air quality is necessary.

실내 미세먼지 측정을 위한 저가형 PM 센서의 실험실/현장 평가 및 보정 방법 (Laboratory/Field evaluation and calibration method of low-cost PM sensor for indoor PM2.5, PM10 measurement)

  • 김도헌;신동민;황정호
    • 한국입자에어로졸학회지
    • /
    • 제18권4호
    • /
    • pp.109-127
    • /
    • 2022
  • Recently, low-cost particulate matter (PM) sensors have been widely used in monitoring mass concentration. Maintaining the accuracy of the sensors is important and requires rigorous performance evaluation and calibration. In this study, two commercial low-cost PM sensors(LCS), Plantower PMS3003 and Plantower PMS7003, were evaluated in the laboratory and field with a reference-grade PM monitor (GRIMM 11-D). Laboratory evaluation was conducted with single/mixed particles of PSL (Poly Styrene Latex) in an acrylic chamber at 20℃ and relative humidity of 20%. Field evaluation was conducted inside a building of Yonsei University (Shinchon) from February 12 to March 31, 2022. In both evaluations, LCS measured values became different from reference measured values when the relative humidity was high or the outdoor air PM10/PM2.5 ratio was high. Based on the field evaluation, the LCS measured values were corrected through four different regression analysis models. As a result, the multivariate polynomial regression analysis model showed highest matching with the reference PM monitor (PM2.5 >0.9, PM10 >0.85). In this model, the PM10/PM2.5 ratio and relative humidity were chosen as independent variables.

확률론적 모의실험 기법을 이용한 일부 지하철 근무자들의 이산화질소 개인노출 시나리오 분석 (Scenario Analysis of Personal Nitrogen Dioxide Exposure with Monte Carlo Simulation on Subway Station Workers in Seoul)

  • 손부순;장봉기;양원호
    • 한국환경과학회지
    • /
    • 제10권3호
    • /
    • pp.195-200
    • /
    • 2001
  • The personal exposures of nitrogen dioxide(NO$_2$), microenvironmental levels and daily time activity patterns on Seoul subway station workers were measured from February 10 to March 12, 1999. Personal NO$_2$exposure for 24 hours were 29.40$\pm$9.75 ppb. NO$_2$level of occupational environment were 27.87$\pm$7.15 ppb in office, 33.60$\pm$8.64 ppb in platform and 50.13$\pm$13.04 ppb in outdoor. Personal exposure time of subway station workers was constituted as survey results with $7.94\pm$3.00 hours in office, $2.82\pm$1.63 hours in platform and 1 hours in outdoor. With above results, personal $NO_2$exposure distributions on subway station workers in Seoul were estimated with Monte Carlo simulation which uses statistical probabilistic theory on various exposure scenario testing. Some of distributions which did not have any formal patterns were assumed as custom distribution type. Estimated personal occupational $NO_2$exposure using time weighted average (TWA) model was 31.$29\pm$5.57 ppb, which were under Annual Ambient Standard (50ppb) of Korea. Though arithmetic means of measured personal $NO_2$exposure was lower than that of occupational $NO_2$exposure estimated by TWA model, considering probability distribution type simulated, probability distribution of measured personal $NO_2$exposures for 24 hours was over ambient standard with 3.23%, which was higher than those of occupational exposure(0.02%). Further research is needed for reducing these 24 hour $NO_2$personal excess exposures besides occupational exposure on subway station workers in Seoul.

  • PDF

일부 학교 내 총부유세균 및 미세먼지의 상관성 비교 (Comparison of Correlation between Total Airborne Bacteria and Particulate Matter in University Spaces)

  • 서혜경;안하림
    • 한국산업보건학회지
    • /
    • 제34권2호
    • /
    • pp.115-124
    • /
    • 2024
  • Objectives: The aim of this study is to assess indoor air quality within and around buildings and evaluate the health risks associated with exposure to indoor air pollution. The study compares IAQ standards established by the World Health Organization with those set by South Korea's Ministry of Environment and Ministry of Education. Methods: The study utilized an Anderson Sampler and DustTrakTM II to collect samples of total airborne bacteria and PM in indoor and outdoor environments. Collected samples were analyzed using biological and biochemical methods. Statistical analysis was conducted using SPSS to examine the correlation between airborne bacteria and PM. Results: The study revealed that the concentration of total airborne bacteria in indoor air generally remained below the Ministry of Environment's standard of 800 CFU/m3, although it surpassed this threshold in certain instances. PM concentrations did not exceed the standards. Indoor fine dust concentration was higher when there were people (P<0.05). There was no difference in total floating bacterial concentrations between indoor and outdoor environments (P=0.184). Finally, there was a correlation between fine dust and airborne bacteria concentrations. Conclusion: The study evaluated the concentrations of total airborne bacteria and PM in indoor air, emphasizing the importance of managing IAQ. Further research in various environments is essential to ensure a healthy indoor environment. The findings underscore the need for ongoing research and management to enhance IAQ and create safer and healthier living environments.

도시아파트의 실내외 $NO_2$ 농도와 관련요인에 관한 연구 (Study on the Indoor-Outdoor $NO_2$ Levels and Related Factors in Urban Apartments)

  • 서병성;김성환;김인식;허윤영;도수영;김정만;김준연
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권3호
    • /
    • pp.609-622
    • /
    • 1997
  • 부산지역의 한 아파트 단지내 489세대를 대상으로 아파트 실내외의 $NO_2$ 농도를 측정하고 동시에 $NO_2$ 농도의 관련 변수들을 조사하여 양자간의 관련성을 파악하고자 본 연구를 실시하였다. 아파트 실내외의 $NO_2$, 농도는 개인용 $NO_2$, 포집관 (Palmes tube)을 사용하여 1995년 8월 16일 - 8월 25일 (하계)과 1996년 1월 15일 - 1월 29일 (동계)간에, 그리고 가스렌지 근처, 주방, 거실 및 아파트 옥외에서 측정하였다. 본 연구의 결과를 요약하면 다음과 같다. 1) 각 세대의 가스렌지 근처와 주방, 거실 및 실외의 평균 $NO_2$, 농도는 하계는 각각 $25.9{\pm}10.0ppb,\;23.3{\pm}8.0ppb,\;19.9{\pm}6.1ppb$$19.0{\pm}6.0ppb$이며, 동계는 $34.5{\pm}16.8ppb\;28.2{\pm}13.4ppb,\;25.3{\pm}12.5ppb$$21.8{\pm}9.8ppb$로서 동하계 공히 부엌의 가스렌지 근처의 $NO_2$, 농도가 최고이었고 하계에 비하여 동계의 실내외 $NO_2$ 농도가 유의하게 높았다. 리 아파트 층수별 $NO_2$ 농도는 하계에는 층수에 따른 $NO_2$, 농도의 유의한 변화가 없었으나, 동계는 16층 이상을 제외하면 층수가 높아짐에 따라 $NO_2$ 농도가 감소하였다. 기 아파트 실내 $NO_2$ 농도의 관련변수는 하계의 경우 층수, 가족수, 1회 식사시 평균 가족수, 취사시 가스렌지 1일 평균 사용횟수, 자연 환기이었고, 동계에는 층수, 가족수, 1회 식사시 평균 가족수, 총 식사 인원수, 식사 횟수, 가족의 총 연령, 취사시 가스렌지 1일 평균 사용 횟수, 조리시 가스렌지 1일 평균 사용 횟수, 호흡기 질환자 유무 등이었다. 4) 아파트 실내 $NO_2$ 농도의 감소 방안으로는 취사 혹은 조리시 환기를 철저히 하고, 완전연소, 연소의 횟수와 시간 단축 및 연료의 대체가 필요하다고 생각한다.

  • PDF

Air Pollution Exposure and Cardiovascular Disease

  • Lee, Byeong-Jae;Kim, Bumseok;Lee, Kyuhong
    • Toxicological Research
    • /
    • 제30권2호
    • /
    • pp.71-75
    • /
    • 2014
  • Ambient air pollution (AAP) and particulate matters (PM) have been closely associated with adverse health effects such as respiratory disease and cardiovascular diseases. Previous studies have examined the adverse health effects associated with short- and long-term exposure to AAP and outdoor PM on respiratory disease. However, the effect of PM size ($PM_{2.5}$ and $PM_{10}$) on cardiovascular disease has not been well studied. Thus, it remains unclear how the size of the inhalable particles (coarse, fine, or ultrafine) affects mortality and morbidity. Airborne PM concentrations are commonly used for ambient air quality management worldwide, owing to the known effects on cardiorespiratory health. In this article, we assess the relationship between cardiovascular diseases and PM, with a particular focus on PM size. We discuss the association of $PM_{2.5}$ and $PM_{10}$, nitrogen dioxide ($NO_2$), and elemental carbon with mortality and morbidity due to cardiovascular diseases, stroke, and altered blood pressure, based on epidemiological studies. In addition, we provide evidence that the adverse health effects of AAP and PM are more pronounced among the elderly, children, and people with preexisting cardiovascular and respiratory conditions. Finally, we critically summarize the literature pertaining to cardiovascular diseases, including atherosclerosis and stroke, and introduce potential studies to better understand the health significance of AAP and PM on cardiovascular disease.

지하철 전동차 객실 내부 공기질 조사 연구 (Research Study on Indoor Air Quality (IAQ) inside of the Subway Cabin in Seoul Metropolitan City)

  • 이경빈;김진식;배성준;김신도
    • 한국대기환경학회지
    • /
    • 제30권2호
    • /
    • pp.175-187
    • /
    • 2014
  • The subways play an important part in serious traffic problems. Almost seven million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan city in 2012. However, the subway system is a semi-closed environment, so many serious problems occurred in subway stations and injured passengers' health. Platform screen doors (PSD) are expected to prevent negligent accident such as injury or death from falling and improve the air quality of the subway station. Installation of PSD at stations in Seoul metropolitan subway had been completed in December 2009. Consequently, the underground transportation system became a closed environment, so the air quality has improved the platforms, but it has deteriorated in the tunnels. Especially, the subway cabin has many doors, and the doors are frequently opened and closed. For this reason, the effect of door opening on subway cabin, dust flow inside the subway cabin. In this process, the maintenance work may influence the health of people who work underground, as well as that of subway users (passengers). In this study, we measured air quality inside and outside of the subway cabin line 2 in Seoul, Korea. This study focused on the investigation of Indoor Air Quality (IAQ) and measurement target pollutants are PM10, CO, $CO_2$, $NO_2$, $O_3$. It was found that levels of PM10, $CO_2$, and $NO_2$ inside subway cabin line 2 exceeded the Korea IAQ standard. Concentrations of PM10, $CO_2$, and $NO_2$ inside of the cabin are higher than outside of the cabin (Indoor Outdoor ratio is higher than 1.). Concentrations of CO, $O_3$ inside of the cabin are lower than outside of the cabin (Indoor Outdoor ratio is lower than 1.). There is a high correlation between $CO_2$ and passengers inside of the cabin and PM10 is only the weakest correlation with passengers. Therefore, it is important to find out the emission source of $NO_2$. The results of this study will be useful as fundamental data to study indoor air quality of a subway cabin.

지하철역에서의 공기질 평가에 관한 연구 - PM-10 및 중금속 - (A Study on the Indoor Air Quality in Subway - PM-10 and Heavy Metals -)

  • 배상호;최우건;박덕신;정우성;김태오
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.555-560
    • /
    • 2002
  • Subway has been used one of major public transportations because of overpopulation and heavy traffic problems in the metropolitan areas. In this study, continuous date of PM-10(particles with aerodynamic diameter < 10$\mu\textrm{m}$) and heavy metal concentration measurements for autumn and winter period were analysed. These measurements have been carried out at the outdoor, concourse, platform, tunnel. The study results showed that the average seasonal concentration of PM-10 particles were 181.01$\mu\textrm{g}$/㎥ in autumn and 129.03$\mu\textrm{g}$/㎥ in winter, respectively. The concentration of Fe, Cu showed the largest peak concentrations during the respective season.

  • PDF

고속버스 운행시 공조시스템 조건에 따른 객실 내 실내공기질 변화 (A study on the effect on indoor air quality by ventilation system operation in buses)

  • 안선민;이정섭;심인근;김호현
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.346-354
    • /
    • 2018
  • In this study, the condition of the hazardous materials in the bus was monitored according to the ventilation mode of the air conditioning system during bus service. The bus was surveyed using the indoor air quality measurement method of public transportation vehicles within one year of delivery. We evaluate the $CO_2$ and $PM_{10}$, which are the controlled parameters in buses by the Ministry of Environment, and VOCs and HCHO, the non-controlled parameters. The $PM_{10}$ concentration increased due to outdoor air intake; however the $CO_2$ concentration was found to decrease. In addition, the concentration of VOCs and HCHO was found to decrease due to the forced ventilation system and the outdoor air intake. These results show that the concentration of the other materials except $PM_{10}$ can be changed due to the outside air concentration and forced ventilation system. Therefore, through indoor air quality characteristics of the bus according to air condition system are intended to be used as the basis of an operation manual.