• Title/Summary/Keyword: Optical interference

Search Result 621, Processing Time 0.033 seconds

A Study on Optical Correlation for Indoor Positioning based LED-ID (LED-ID기반 실내 위치인식을 위한 Optical Correlation에 관한 연구)

  • Lee, Jung-Hoon;Cha, Jae-Sang
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.75-80
    • /
    • 2013
  • In this paper, We proposed a Optical Correlation for indoor positioning based LED-ID. The proposed Optical Correlation has a advantage to low-interference between spread code number sequences and LED-ID. it is applied a spread code to reduce the interference with additional information based LED-ID. The additional information is enable to detect in transmitted signal using auto correlation. Also we designed and implemented the Optical Correlation for clearly detecting the additional information. Simulations were performed to confirm the performance of BER and the power of additional information. Optical Correlation simulator to indoor positioning based LED-ID was implemented to prove a usefulness.

Multiple Access Interference Suppressed Sensor Network Using Optical CDMA with Bipolar Receiver and Modified PN Code (간섭잡음을 억압한 양극성 수신기와 PN 부호에 의한 광 CDMA 방식을 사용한 센서 네트워크)

  • Park Sang-Jo;Kim Bong-Kyu
    • The KIPS Transactions:PartC
    • /
    • v.13C no.3 s.106
    • /
    • pp.311-316
    • /
    • 2006
  • We propose the optical sensor network using optical CDMA with bipolar receiver and modified Pseudorandom Noise codes which are widely used in the wireless communication network. We numerically analyze the performances in the optical sensor network. In the proposed network, multiple access interferences between two sensors are suppressed by performing synchronization between the optical encoder and the optical decoder and adjusting the delay times of optical delay lines. Numerical simulations confirm that the performance can be acquired by suppressing the beat noise among optical signals as the number of sensors increases.

Implementation of Novel Bio-sensor Platform based on Optical MMI and Directional Coupler (광 MMI와 방향성 결합기에 기초한 새로운 바이오 센서 플랫폼의 구현)

  • Kwang-Chun Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.163-168
    • /
    • 2023
  • In this paper, a novel platform for chemical sensing and biosensing is presented. The working principle is based on the coupling efficiency and interference properties of optical directional coupler (DC) and multimode interference coupler (MMIC). It has been realized using planar technology to allow integration on a silicon substrate. Firstly, the dispersion curves of DC and MMIC is described, and the design specification of an optimized slot optical waveguide to increase waveguide sensitivity is selected. Next, the sensor response to the refractive index change of sensing analyte is numerically simulated. The numerical results reveal that high effective index change per refractive index unit (RIU) change of analyte is obtained, and the sensitivity can be tuned using the DC and MMIC design technique.

Analysis and Design of Si3N4 Rib-optical Waveguides for Evanescent-wave Integrated-optical Biosensors (소산파 집적광학 바이오센서에 적합한 Si3N4 립-광도파로 해석 및 설계에 관한 연구)

  • Jung, Hongsik
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.1
    • /
    • pp.15-22
    • /
    • 2019
  • $Si_3N_4$ rib-optical waveguides for evanescent-wave integrated-optical biosensors were analytically interpreted, to derive the single-mode propagation conditions. The integrated-optical biosensor structure based on two-mode interference was proposed, and the rib width and thickness and core thickness for a single-mode and two-mode waveguide (sensing region) were proposed to be $3{\mu}m$, 2 nm, and 150 nm and $3{\mu}m$, 20 nm, and 340 nm respectively. The optical characteristics of each guided-wave mode were investigated utilizing the film mode-matching (FMM) analysis.

A Narrow Band MILES Detection System With Reduced Blind Angle of Detection Using Refractors (굴절체를 이용하여 감지 사각 문제를 개선한 협대역 마일즈 감지 시스템)

  • Ki, Hyeon-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.7
    • /
    • pp.10-16
    • /
    • 2012
  • In this paper, we tried to realize a next generation MILES detection system which is robust to optical noise using a narrow band interference optical filter. Applying a narrow band interference optical filter which has the wavelength range of 895~915nm to the LASER wavelength of 900nm, we could obtain detection characteristics robust to strong optical noise which can be occurred in street battles. However, the MILES detection system has the blind range of detection in the incident angle range of $30^{\circ}{\sim}90^{\circ}$. To solve this problem we proposed a method of incident angle scatter using refractors. Applying a concave meniscus lens refractor which has diopter of 5.4 to the MILES detection system, we could eliminate the blind angle of detection.

Common-path Optical Interferometry for Stabilized Dynamic Contrast Imaging: A Feasibility Study

  • Seung-Jin, Lee;Young-Wan, Choi;Woo June, Choi
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2023
  • The motion of organelles inside a cell is an important intrinsic indicator for assessing cell physiology and tissue viability. Dynamic contrast full-field optical coherence tomography (D-FFOCT) is a promising imaging technology that can visualize intracellular movements using the variance of temporal interference signals caused by biological motions. However, double-path interferometry in D-FFOCT can be highly vulnerable to surrounding noise, which may cause turbulence in the interference signals, contaminating the sample dynamics. Therefore, we propose a method for stabilized D-FFOCT imaging in noisy environments by using common-path interferometry in D-FFOCT. A comparative study shows that D-FFOCT with the proposed method achieves stable dynamic contrast imaging of a scattering phantom in motion that is over tenfold more noise-insensitive compared to the conventional one, and thus this imaging capability can provide cleaner motion contrast images. With the proposed approach, the intracellular dynamics of biological samples are imaged and monitored.