• Title/Summary/Keyword: Optical Flow Sensor

Search Result 84, Processing Time 0.028 seconds

Effects of Oscillating Flow on the Dynamic Behavior of an Artificial Sensory Hair (인공 감각모의 동적 거동에 미치는 진동유동의 영향)

  • Park, Byung-Kyu;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.847-853
    • /
    • 2011
  • Filiform hairs that respond to movements of the surrounding medium are the mechanoreceptors commonly found in arthropods and vertebrates. The hairs function as a sensory system for perceiving information produced by prey, predators, or conspecifics. A mathematical model is proposed, and the parametric analyses for the response of artificial filiform hair are conducted to design and predict the performance of a microfabricated device. The results for the Cytop hair, one of the most popular polymer optical fibers (POFs), show that the fundamental mode has a dominant effect on the hair behavior in an oscillating medium flow. The dynamic behavior of sensory hair is also dependent on the physical dimensions such as length and diameter. It is found that the artificial hair with a high elastic modulus does not show a resonance in the biologically important frequency range.

Yield monitoring systems for non-grain crops: A review

  • Md Sazzadul Kabir;Md Ashrafuzzaman Gulandaz;Mohammod Ali;Md Nasim Reza;Md Shaha Nur Kabir;Sun-Ok Chung;Kwangmin Han
    • Korean Journal of Agricultural Science
    • /
    • v.51 no.1
    • /
    • pp.63-77
    • /
    • 2024
  • Yield monitoring systems have become integral to precision agriculture, providing insights into the spatial variability of crop yield and playing an important role in modern harvesting technology. This paper aims to review current research trends in yield monitoring systems, specifically designed for non-grain crops, including cabbages, radishes, potatoes, and tomatoes. A systematic literature survey was conducted to evaluate the performance of various monitoring methods for non-grain crop yields. This study also assesses both mass- and volume-based yield monitoring systems to provide precise evaluations of agricultural productivity. Integrating load cell technology enables precise mass flow rate measurements and cumulative weighing, offering an accurate representation of crop yields, and the incorporation of image-based analysis enhances the overall system accuracy by facilitating volumetric flow rate calculations and refined volume estimations. Mass flow methods, including weighing, force impact, and radiometric approaches, have demonstrated impressive results, with some measurement error levels below 5%. Volume flow methods, including paddle wheel and optical methodologies, yielded error levels below 3%. Signal processing and correction measures also play a crucial role in achieving accurate yield estimations. Moreover, the selection of sensing approach, sensor layout, and mounting significantly influence the performance of monitoring systems for specific crops.

Improved switching method for sensorless BLDC motor drive (Sensorless BLDC 전동기 구동을 위한 개선된 스위칭 방법)

  • Lee, Ho-Hyoung;Cho, Whang;Lee, Key-Seo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.2
    • /
    • pp.164-170
    • /
    • 2010
  • In brushless DC motor, current flow should be controlled such that only properly selected 2 out of 3 phases carry current depending on the position of rotor. In order to detect position of rotor, hole sensor, encoder, optical position-detecting sensor, and magnetic position-detecting sensor are frequently employed. These sensors not only often cause malfunction in low and high temperature but they also have disadvantage of increasing cost and size of an motor system. To reduce the cost and size and to increase the robustness of the motor system, recently researches on sensorless motor dirve are very active. This paper proposes a novel unipolar PWM switching method that can improve the control problem caused by the difficulty of detecting zero crossing point at high revolution speed by minimizing the switching noise while increasing the lifespan of the drive system.

Improvement of turbid water prediction accuracy using sensor-based monitoring data in Imha Dam reservoir (센서 기반 모니터링 자료를 활용한 임하댐 저수지 탁수 예측 정확도 개선)

  • Kim, Jongmin;Lee, Sang Ung;Kwon, Siyoon;Chung, Se Woong;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.11
    • /
    • pp.931-939
    • /
    • 2022
  • In Korea, about two-thirds of the precipitation is concentrated in the summer season, so the problem of turbidity in the summer flood season varies from year to year. Concentrated rainfall due to abnormal rainfall and extreme weather is on the rise. The inflow of turbidity caused a sudden increase in turbidity in the water, causing a problem of turbidity in the dam reservoir. In particular, in Korea, where rivers and dam reservoirs are used for most of the annual average water consumption, if turbidity problems are prolonged, social and environmental problems such as agriculture, industry, and aquatic ecosystems in downstream areas will occur. In order to cope with such turbidity prediction, research on turbidity modeling is being actively conducted. Flow rate, water temperature, and SS data are required to model turbid water. To this end, the national measurement network measures turbidity by measuring SS in rivers and dam reservoirs, but there is a limitation in that the data resolution is low due to insufficient facilities. However, there is an unmeasured period depending on each dam and weather conditions. As a sensor for measuring turbidity, there are Optical Backscatter Sensor (OBS) and YSI, and a sensor for measuring SS uses equipment such as Laser In-Situ Scattering and Transmissometry (LISST). However, in the case of such a high-tech sensor, there is a limit due to the stability of the equipment. Therefore, there is an unmeasured period through analysis based on the acquired flow rate, water temperature, SS, and turbidity data, so it is necessary to develop a relational expression to calculate the SS used for the input data. In this study, the AEM3D model used in the Water Resources Corporation SURIAN system was used to improve the accuracy of prediction of turbidity through the turbidity-SS relationship developed based on the measurement data near the dam outlet.

Signal Analysis of Optical Biosensor to Detect Peroxide Using Electrically Controlled Release System (전기적 방출 조절 시스템을 이용한 광 페록사이드센서의 개발)

  • Min, Jun-Hong;Lim, In-Hee;Kim, Hyo-Han;Lee, Sang-Beak;Choi, Jeong-Woo;Lee, Won-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.35-42
    • /
    • 1997
  • The optical biosensor using the electrically controlled release of reactive reagent is developed for the detection of peroxide. Rapid degradation of polymer complex of PEOx and PMAA occurs as the applied current increases and thus released amount of HPA increases. The degradation velocity of polymer and the amount of HPA released are linearly proportional to the applied current. Peroxide is reacted with the released reagent by peroxidase and then the product, a fluorescent dimer DBDA, is formed. The monochromic light from light source (150W Xe arc ramp) excites the DBDA and the excited light is transmitted through an optical fiber to be detected by a photodiode array. The change of fluorescence intensity is related to the change of peroxide concentration. The peroxidase is entrapped in Ca-alginate get on the inner surface. The biosensor has the linear signal range of 0.025mM-10.mM peroxide. By applying the step function of peroxide, reproducibility of biosensor has been investigated. The mathematical model is constructed by the combination of enzyme kinetics with reactor flow model. Good agreement is obtained between the experimental result and model prediction in the sensor signal.

  • PDF

Fabrication and Characteristics of Photoconductive Amorphous Silicon Film for Facsimile (팩시밀리용 비정질 실리콘 광도전막의 제작 및 특성)

  • Kim, Jeong-Seob;Oh, Sang-Kwang;Kim, Ki-Wan;Lee, Wu-Il
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.6
    • /
    • pp.48-56
    • /
    • 1989
  • Contact-type linear image sensors for facsimile have been fabricated by means of rf glow discharge decomposition method of silane. The dependence of their electrical and optical properties on rf power, $SiH_4$ flow rate, ambient gas pressure, $H_2SiH_4$ ratio and substrate temperature are described. The a-Si:H monolayer demonstriated photosensitivity of 0.85 and $I_{ph}/I_d$ ratio of 100 unger 100 lux illumination. However, this monolayer has relatively high dark current due to carrier injection from both electrodes, resulting in low $I_{ph}/I_{dd}$ ratio. To suppress the dark current we have fabricated $SiO_2/i-a-Si:H/p-a-Si:H:B$ multilayer film with blocking structure. The photocurrent of this multilayer sensor with 6 V bias became saturated ar about 20nA under 10 lux illumination, while the dark current was less than 0.2 nA. Moreover, the spectral sensitivity of the multilayer film was enhanced for short wavelength visible region, compared with that of the a-Si:H monolayer. These results show that the fabricated photocon-ductive film can be used as the linear image sensor of the facsimile.

  • PDF

Non-invasive Blood Glucose Detection Sensor System Based on Near-Infrared Spectroscopy (근적외선 분광법 기반 비침습식 혈당 검출 센서 시스템)

  • Kang, Young-Man;Han, Soon-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.991-1000
    • /
    • 2021
  • Among non-invasive blood glucose detection technologies, the optical technique is a method that uses light reflection, absorption, and scattering characteristics when passing through a biological medium. It reduces pain or discomfort in measurement and has no risk of infection. So it is becoming a major flow of blood glucose detection research. Among them, near-infrared spectroscopy has a disadvantage in that the complexity increases when analyzing signals detected due to interferences between proteins and acids that share a similar absorption function with blood glucose molecules. In this study, a non-invasive sensor system with multiple near-infrared bands was designed and manufactured to alleviate the deterioration of blood glucose detection function that may occur due to skin absorption of near-infrared rays. A blood survey was conducted to verify the system, and the degree of blood glucose response in the blood was collected as spectral data, and the results of this study were quantitatively verified in terms of correlation between the data and blood glucose.

A noble RBC aggregometer with vibration-induced disaggregation mechanism

  • Shin S.;Jang J.H.;Park M.S.;Ku Y.H.;Suh J.S.
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2005
  • The aggregation of red blood cells (RBCs) is a major determinant of blood flow resistance passing through various veins. Available techniques for measuring RBC aggregation often require pretreating and washing after each measurement, which is not optimal for day-to-day clinical use. A laser reflection technique has been combined with a vibration-aided disaggregation mechanism, which shows significant advances in aggregometer design, operation and data analysis. The essential features of this design are in its simplicity and a disposable element that is in contact with the blood sample. Using extremely small quantities of blood, the RBCs subjected to vibrations can be quickly and completely disaggregated. This is followed by measuring the backscattered light intensity. The measurements with the present sensor were compared with those of a commercial aggregometer and a strong correlation was found between them. The newly-developed optical aggregometer can measure the RBC aggregability difference between young and old cell suspension with ease and accuracy.

Rapid Topological Patterning of Poly(dimethylsiloxane) Microstructure (Poly(dimethylsiloxane) 미세 구조물의 신속한 기하학적 패터닝)

  • Kim, Bo-Yeol;Song, Hwan-Moon;Son, Young-A;Lee, Chang-Soo
    • Textile Coloration and Finishing
    • /
    • v.20 no.1
    • /
    • pp.8-15
    • /
    • 2008
  • We presented the modified decal-transfer lithography (DTL) and light stamping lithography (LSL) as new powerful methods to generate patterns of poly(dimethylsiloxane) (PDMS) on the substrate. The microstructures of PDMS fabricated by covalent binding between PDMS and substrate had played as barrier to locally control wettability. The transfer mechanism of PDMS is cohesive mechanical failure (CMF) in DTL method. In the LSL method, the features of patterned PDMS are physically torn and transferred onto a substrate via UV-induced surface reaction that results in bonding between PDMS and substrate. Additionally we have exploited to generate the patterning of rhodamine B and quantum dots (QDs), which was accomplished by hydrophobic interaction between dyes and PDMS micropatterns. The topological analysis of micropatterning of PDMS were performed by atomic force microscopy (AFM), and the patterning of rhodamine B and quantum dots was clearly shown by optical and fluorescence microscope. Furthermore, it could be applied to surface guided flow patterns in microfluidic device because of control of surface wettability. The advantages of these methods are simple process, rapid transfer of PDMS, modulation of surface wettability, and control of various pattern size and shape. It may be applied to the fabrication of chemical sensor, display units, and microfluidic devices.

A study of Detecting Fish Robot Position Using The Define Average Color Weight Algorithm (평상 색상 구분 알고리즘을 이용한 물고기 로봇 위치 검출 연구)

  • Angani, Amaranth Varma;Lee, Ju Hyun;Shin, Kyoo Jae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1354-1357
    • /
    • 2015
  • In this paper, the designed fish robot is researched and developed for aquarium underwater robot. This paper is a study on how the outside technology merely to find the location of fish robots without specific sensor or internal devices for these fish robot. The model of the fish is designed to detect the position of the optical flow of the Robotic Fish in the Simulink through Matlab. This paper intends to recognize the shape of the tank via a video device such as a camera or camcorder using an image processing technique to identify the location of the robotic fish. Here, we are applied to the image comparing algorithm by using the average color weight algorithm method. In this, position coordinate system is used to find the position coordinates of the fish to identify the position of the Robotic fish. It was verified by the performance test of design robot.