• Title/Summary/Keyword: Ophthalmic material

Search Result 127, Processing Time 0.029 seconds

Optical Properties of Annealed ZnS Single Crystal (열처리한 ZnS 단결정의 광학적 특성)

  • Lee, Il Hun;Ahan, Chun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.97-103
    • /
    • 1999
  • Zinc sulfide is a ll-VI compound with a large direct band gap in the near-UV region and a promising material for blur-light emitting diode and laser diode. It was identified that the structure had zinc blonde structure through the analysis of X-ray diffraction patterns. It's lattice constant was measured to be $a_o=5.411{\AA}$. The optical absorption, photocurrent, and photoluminescence spectra were measured to investigate the optical properties of zinc sulfide single crystal. The optical energy band gap measured at room temperature was 3.61eV The energy band gap of zinc sulfide annealed in zinc vapor at $800^{\circ}C$ was lower 0.1eV than that of as-grown zinc sulfide through the analysis of the photocurrent spectra. The photoluminescence spectra were measured ranging from 30K to 293K for the two cases of as-grown and annealed zinc sulfide. As-grown ZnS single crystal had peaks at 350nm, 392nm, 465nm, and annealed zinc sulfide had peaks at 349nm.

  • PDF

A Design of Eye-glasses on the Correct Aberration of Astigmatism (비점수차 (Astigmatism)가 제거된 안경렌즈 설계)

  • Lim, Hyeonseon;Ji, Taeksang;Park, Sang Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.121-128
    • /
    • 1998
  • In this paper, We researched the optical performance of eye by means of the Gullstrand EYE MODEL. And we also researched the glasses that are made by designing the eye glasses corrected with the Astigmatism and the optical performance of the glasses in the optical system which are compounded with eyes. This paper can be used as a reference material in designing the glasses for ametropic correction.

  • PDF

The Performance Stability of Ophthalmic Material with UV-Block Effect Containing Hydroxyl Benzophenone Group and Tungsten Nanoparticles

  • Kim, Duck-Hyun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.3
    • /
    • pp.97-103
    • /
    • 2017
  • In this study, the functional hydrogel ophthalmic lens containing tungsten oxide nanoparticles, 2,4-dihydroxy benzophenone and 2-hydroxy-4-(methacryloyloxy) benzophenone were manufactured. HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), AA(acrylic acid), the cross-linker EGDMA (ethylene glycol dimethacrylate), the initiator AIBN (azobisisobutyronitrile) and the functional additives including tungsten oxide nanoparticles, 2,4-dihydroxy benzophenone, and 2-hydroxy-4-(methacryloyloxy) benzophenone were used respectively. The measurements of water content and refractive index of the sample was decreased and increased, respectively. And also, the UV transmittance of produced lens containing 2,4-dihydroxy benzophenone, 2-hydroxy-4-(methacryloyloxy) benzophenone and tungsten oxide nanoparticles was measured. Based on the results of this study, it is judged that the performance improvement increased over time when 2-hydroxy-4-(methacryloyloxy) benzophenone was used as an additive, while the use of tungsten oxide nanoparticles influenced on blue-ray-blocking effect of the hydrophilic lens.

K Hospital Lasik Center Interior Design (K병원 라식센타 인테리어 디자인)

  • Kim, Jung-Shin;Im, Oh-Yeoun
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.273-274
    • /
    • 2005
  • The purpose of this design is to find out the design for an ophthalmic hospital focusing on the patient needs and changed healthcare environment. A cellularized hospital system appears variety design. This space needs well-balanced and ease of mind, because of ophthalmic needs a clear description attention. The concept of this design is to give human colour intellect and rich colour-sense. The waiting area wall is finished the graphic design sheet of leaves, which is covered with the fluting glass and indirect lighting. The colour is extracted in nature. The colour techniques of graphic design is gradation, the colour plan select from Y to G-GB. The material is selected within natural colour. The treatment area is functional space and the waiting area is sensitivity space. The hospital design must change with user as a leader.

  • PDF

Self-Reported Symptoms and Stereopsis in Viewing 2D and 3D Images (2D와 3D입체 영상 시청에서 나타난 자각 증상과 입체시)

  • Lee, Wook-Jin;Son, Jeong-Sik;Kwak, Ho-Won;Kim, In-Su;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.83-90
    • /
    • 2011
  • Purpose: This study aimed to compare and assess whether there was a relation between self-reported symptom and stereopsis in viewing an anaglyph 3D and a general 2D image. Methods: Seventy subjects (38 males, 32 females) were students ranging in age from 20 to 30 years. Subjects' symptoms were investigated by a questionnaire after viewing the 2D image and the anaglyph 3D image using red-green glasses for 30 minutes. Titmus circles and TNO stereopsis tests were performed before and after the images. A correlation between symptom and stereopsis was evaluated. Results: Both ocular and nonocular symptom in viewing 3D image were higher than those in 2D image. Titmus circles stereopsises using polarized filters were not changed before and after viewing images, but TNO stereopsises using color filters such as red-green glasses were increased after viewing 3D image. Ocular symptom and TNO stereopsis were increased after viewing 3D image, and there was a good correlation between them (r=0.605). Conclusions: Better stereopsises before viewing 3D are relatively lower ocular symptoms in viewing 3D image. But symptoms are increased in viewing anaglyph 3D image for a short-time and improvement of TNO steropsis is poorly associated with the relief of ocular symptoms. This tendency seems to be related with an adaptation to anaglyph 3D image with red-green glasses.

Comparison of Corneal Edema Induced by Material of Contact Lens (콘택트렌즈의 재질별 각막부종의 비교)

  • Kim, Ki-Sung;Kim, Sun-Kyung;Kim, Tae-Hun;Kim, Hyo-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.151-156
    • /
    • 2015
  • Purpose: This study has been compared the degree of corneal edema arising from the material of the lens after wearing the recommended wearing time for the contact lens. Methods: For the study, 43 adults of 77 eyes who did not use drugs and have not any disease participated. Three types of lenses including narafilcon A, HEMA, and silicone hydrogel material regular replaceable lenses were used. Central corneal thickness was measured before and after 8 hours from wearing lenses using Pentacam. The degree of corneal edema was determined by the difference before and after wearing. Results: The average corneal edema of narafilcon A, HEMA material lens, and silicone hydrogel material regular replaceable lens were $2.36{\pm}6.15{\mu}m(Mean{\pm}SD)$, $23.61{\pm}10.71{\mu}m$, $18.25{\pm}8.64{\mu}m$, respectively. The central corneal thickness after wearing narafilcon A was not statistically significant with the central corneal thickness before wearing the lens. Central corneal thickness before and after wearing HEMA material lens and silicone hydrogel material regular replaceable lens were statistically significant. Conclusions: The amount of corneal edema induced by silicone hydrogel material regular replaceable lens was no statistically significant difference to the amount of corneal edema induced by HEMA material lens, but there was significant difference to narafilcon A. Therefore, it is judged to be careful not to exceed the recommended wearing time depending on the composition of the contact lens material.

Synthesis of Polymer Materials Containing Platinum Nanoparticles and Their Application for Contact Lenses (백금 나노입자를 포함한 고분자재료의 합성 및 콘택트렌즈로의 응용)

  • Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.99-104
    • /
    • 2010
  • Platinum nanoparticles were added to a mixture of HEMA (2-hydroxyethyl methacrylate), NVP (N-vinyl pyrrolidone) and MMA (methyl methacrylate) in a mould at various concentrations. The resulting mixture was copolymerized by heating at $70^{\circ}C$ for 40 min, $80^{\circ}C$ for 40 min, and $100^{\circ}C$ for 40 min, respectively. The physical properties of contact lens were then measured. The oxygen transmissibility of $9{\sim}15{\times}10^{-9}$ cm/s mL $O_2$/mL ${\times}$ mmHg, water content of 34.22~35.52%, refractive index of 1.432~1.435, visible transmittance of 88.3~91.2% and tensile strength of 0.141~0.152 kgf were obtained. The addition of platinum nanoparticles to the polymer allowed the contact lens to have various colors without artificial coloring agents. The polymer materials satisfied the physical properties required to produce contact lenses, making the material suitable to be applied as a functional material for ophthalmological purposes.

Determination of Optical Constants of Organic Light-Emitting-Material Alq3 Using Jellison-Modine Dispersion Relation (Jellison Modine 분산식을 이용안 유기발광물질 Alq3의 광학상수 결정)

  • Park, Myung-Hee;Lee, Soon-Il;Koh, Ken-Ha
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.267-272
    • /
    • 2005
  • We deposited thin films of organic light-emitting-material $Alq_3$(alumina quinoline) on silicon and slide-glass substrates using thermal evaporation method, and measured spectra of ellipsometry angles ${\Delta}$ and ${\Psi}$ in the photon-energy range of 1.5~5.0 eV using a variable angle spectroscopic ellipsometer. The optical constants, refractive index and extinction coefficient, of $Alq_3$ were determined via the dispersion parameters extracted from the curve-fitting process based on Jellison-Modine dispersion function. The reliability of determined optical constants were verified through the comparison of measured and simulated transmittance curves and the good agreement between simulated absorption-coefficient curves and absorbance spectra measured using a spectrophotometer.

  • PDF

The Comparative Analysis for the Progression of Dry Eyes Caused by Wearing Soft Contact Lenses(SCL) and Cosmetic Soft Contact Lenses(C-SCL) (소프트 콘택트렌즈와 미용 콘택트렌즈의 건성안 진행에 대한 비교분석)

  • Kim, Myoung-Jin;Hwang, Hye-Kyung;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.375-381
    • /
    • 2011
  • Purpose: The purpose of this research was to see how wearing either a SCL or a C-SCL effected the dryness of a person's eye depending on how long they wear either type of lens. Methods: This study was carried out on 52 subjects (104 eyes) who were all in their twenties and had previously experienced wearing contact lenses. All of these subjects were required to wear either a SCL or a C-SCL, which were made out of the same material, for three months. Contents such as the McMonnies Questionnaire survey, the blinking rate per min. and the Noninvasive tear break-up time test (NIBUT) were later conducted on the subjects for this study. Results: According to the results of the McMonnies Questionnaire, it was concluded that the longer the subject wore the SCL and C-SCL, the value of the measurements gradually increased. On the other hand, the results from the NIBUT concluded that the longer the subject wore the SCL, the value of the measurements eventually decreased. However, according to the measurements of the blink rate test, it was concluded that neither results had a significant change. Conclusions: It was concluded that long-term wearing of SCL and C-SCL could be the cause of the induction and progression of dry eyes.

Study on the Development of Wet Cell Holder for the Measurement of Hydrophilic Contact Lens (친수성 콘택트렌즈 측정용 Wet Cell 홀더 개발에 관한 연구)

  • Song, Kyoung-Sek;Lim, Hyeon-Sun;Joo, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.455-462
    • /
    • 2015
  • Purpose: To develop more accurate wet measuring system combining the wet cell, automatic lensmeter and the related software for hydrophilic contact lenses and to verify the accuracy of those measuring holder system already available in the market. Methods: Refractive power measurement were done in both a conventional method which has been commonly used in optical shops and a new method which is recently developed in korea. Hydrophilic contact lens of korean brand was chosen as a test material and was tested by water content ratio and by spherical refractive power. Results: When spherical power of -3.00 D contact lens is measured in the newly developed wet cell measurement holder with automatic lensmeter, it reads -3.01 D at water content ratio of 38%. -3.00 D at 45% and -2.98 D at 58%. The same experiment with the Poster soft contact lens wet cell measurement holder maintaining other conditions same resulted in -3.60 D at the water content ratio of 38%, -3.06 D at 45% and -2.46 D at 58%. Conclusions: At the higher water content, the refractive power values measured by both of the wet cell measuring holders are shown lower, and additionally, the new method using the wet cell holder and new software program in a automatic lensmeter showed more accurate readings than conventional Poster soft contact lens wet cell measuring system.