• Title/Summary/Keyword: Ophthalmic material

Search Result 127, Processing Time 0.032 seconds

Study on the Functionality and Application of Natural-polymer with Biocompatibility (생체적합성을 가진 천연고분자의 응용 및 기능성에 관한 연구)

  • Kim, Tae-Hun;Kim, Doo-Eon;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.5
    • /
    • pp.547-552
    • /
    • 2009
  • Chitosan, a natural polymer, has been importantly considered as biomedical materials due to its good biocompatibility and various bio-active characteristes. Water soluble chitosan was then copolymerized EGDMA(ethylene glycol dimethacrylate; used as a cross-linking agent for the free-radical copolymerization), MMA (methylmethacrylate), MA (methacrylic acid) in the presence of AIBN (azobisisobutyronitrile) as a radical initiator. The water content and visible transmissibility, ultimate strength of copolymerized ophthalmic polymer were measured to be 24$\sim$59%, 88$\sim$89% and 0.1$\sim$2.4 Kgf, respectively. And also, we tested for antimicrobial activities against staphylococcus aureus, Pseudomonas aeruginosa. They showed that in case of antimicrobial activities, the values including chitosan were much higher than that of the polymers of no including chitosan, suggesting that the copolymer can be used as a novel ophthalmic material of high performance.

Polymerization and Characterization of Ophthalmic Polymer Containing Glycerol dimethacrylate with High Wettability (Glycerol dimethacrylate를 포함한 고습윤성 안의료용 고분자의 중합 및 특성)

  • Cho, Seon-Ahr;Kim, Tae-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.283-289
    • /
    • 2011
  • This study used glycerol dimethacrylate with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), MA (methacrylic acid) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical properties of the copolymerized polymer showed that the water content was 22~32%, refractive index was 1.442~1.463 and visible ray transmittance 90.0~90.5% while the contact angle showed a distribution between 56 and $65^{\circ}$. Also, the measurement showed that the decreased amount of contact angle of the copolymer measured using the sessile drop method ranged between $9.89^{\circ}$ and $18.99^{\circ}$ with increase of glycerol dimethacrylate. Based on the results of this study, the produced copolymer is suitable for use as a material to high wettability ophthalmic lenses.

Characterization of Hydrogel Tinted Contact Lens Containing 4-iodoaniline using Titanium Silicon Oxide Nanoparticles as Additive (티타늄 실리콘 옥사이드 나노입자를 첨가제로 사용한 4-iodoaniline을 포함한 하이드로젤 착색 콘택트렌즈의 특성)

  • Cho, Seon-Ahr;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.315-322
    • /
    • 2014
  • Purpose: The physical and optical characteristics of hydrophilic tinted contact lens containing titanium silicon oxide nanoparticles and the basic hydrogel contact lens material containing 4-iodoaniline were examined. In this study, the utility of titanium silicon oxide nanoparticles as a UV-blocking material for ophthalmologic devices were investigated by measuring the UV transmittance of the produced polymer. Also, titanium silicon oxide nanoparticles only without the addition of 4-iodoaniline in primary contact lens materials by copolymerizing two groups were compared. Methods: For manufacturing hydrogel lens, HEMA, MA, MMA, 4-iodoaniline and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. Also, the titanium silicon oxide nanoparticles was used as additive. After polymerization the physical properties such as water content, refractive index, contact angle and spectral transmittance of produced contact lenses were measured. Results: Measurement of the physical properties of the copolymerized material showed that the water content, refractive index, UV-B transmittance and contact angle were in the range of 35.01~38.60%, 1.4350~1.4418, $34.15{\sim}57.25^{\circ}$ and 1.0~10.0%, respectively. Titanium silicon oxide nanoparticles is not used as an additive in the experimental group, the results of the measurement showed that the water content, refractive index, contan angle and UV-B transmittance of the hydrogel lens polymer was 34.00~36.80%, 1.4378~1.4420, $40.15{\sim}60.16^{\circ}$ and 1.8~25.0%, respectively. Conclusions: Also, the transmittance for UV light was reduced significantly in combinations containing titanium oxide nanoparticles.

Influence of Wetting Agents on Physical Properties of Soft Contact Lens (친수성 소프트 콘택트렌즈의 물리적 특성에 미치는 습윤성 재료의 영향)

  • Lee, Min-Jae;Sung, A-Young;Kim, Tae-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • Purpose: The physical and optical characteristics of hydrophilic contact lens polymerized with addition of glycerin and PVP(polyvinylpyrrolidone) in the basic hydrogel contact lens material were evaluated. Methods: This study used glycerin and PVP(polyvinylpyrrolidone) with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Results: Measurements of the physical characteristics of the copolymerized material including PVP(polyvinylpyrrolidone) showed the refractive index of 1.4382~1.4288, tensile strength of 0.3446~2542 kgf and water content and contact angle of sample showed the increase of 13.49% and decrease of 21.44% independently. And also, the physical characteristics of the copolymerized material including glycerin showed the refractive index of 1.4330~1.4328, tensile strength of 0.2974~0.2854 kgf, water content 35.58~36.53% and contact angle of sample showed the decrease of 37.64%. Conclusions: Based on the results of this study, the produced copolymers is suitable for conventional lens with high wettability. Also, glycerin minimized the changes of water content and refractive index at the same time, increased the wettability of the hydrogel lens materials.

Design of Myopic Aspherical Ophthalmic Lenses with Peripheral Clear Vision and Properties of Its Ultra-Precision Machining (선명한 주변시를 가진 근시용 비구면 안경렌즈 설계와 초정밀 가공 특성)

  • Kim, Dong-Ik;Huh, Myeng-Sang;Lee, Gil-Jae;Park, Soon-Sub;Won, Jong Ho;Kim, Geon Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.12
    • /
    • pp.1290-1295
    • /
    • 2012
  • Oblique astigmatism according to the rotation of the eye has to be removed for obtaining peripheral clear vision in ophthalmic lenses. For this reason, we calculated tangential and sagittal power using third-order approximation theory and then controlled conic constant for the difference of the two powers to converge to 0 regardless of the rotation angle of the eye. As a result, an aspherical ophthalmic lens without oblique astigmatism was designed. Also, we found optimal machining condition to the lens material using factorial design and finally fabricated the designed lens through ultra-precision machining with that condition.

Study on the Novel Materials Containing Nanoparticles and Isocyanate Group for Strength Improvement of Hydrogel Ophthalmic Lens

  • Lee, Min-Jae;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.11 no.2
    • /
    • pp.113-120
    • /
    • 2018
  • This study was planned to prepare the high strength hydrogel ophthalmic lens containing isocyanate group and nanoparticles. HDI with carbon nanoparticles were used as additives for the basic combination of HEMA, MA and MMA, and the materials were copolymerized with EGDMA as the cross-linking agent and AIBN as the initiator. The mixture was heated at $100^{\circ}C$ for an hour to produce the high performance hydrogel ophthalmic lens by cast mold method. Measurement of the physical characteristics of the produced material showed that the refractive index was in the range of 1.4027~1.4600, water content 25.21~44.01%, contact angle $54.18{\sim}72.94^{\circ}$, visible light transmittance 53.03~92.09%, and tensile strength 0.1024~0.2359 kgf and breaking strength was 0.0872~0.2825 kgf. The results showed an increase of refractive index while the decrease in water content. And also, the breaking strength was highest when the addition ratio of HDI was 5%(wt). As a result of the absorbance measurement, no significant difference was observed in all the samples, so it can be judged that the stabilization of nanoparticles in the polymer was maintained.

THERMAL POLYMERIZATION OF 2-HYDROXYETHYL METHACRYLATE WITH PHENYLSILANS (PHENYLSILANS와 2-HYDROXYETHYL METHACRYLATE의 열중합)

  • Sung, A Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.87-90
    • /
    • 2000
  • Poly(HEMA)s have been used as the optometric material for the preparation of soft contact lens. The bulk thermal polymerization of 2-hydroxyethyl methacrylate (HEMA) with various hydrosilanes such as $phSiH_3$, $phMeSiH_2$, and $ph2SiH_2$ were performed to produce poly(HEMA)s containing phenylsilyl end moeity. It was found for thermal polymerization that while the polymerization yield and polymer molcular weights decreased as the relative phenylsilane concentration increases, the TGA residue yields and the relative intensities of SiH IR stretching bands increased as the relative hydrosilane concentration increases over HEMA. The polymerization yield, molecular weight, and TGA residue for the thermal polymerization were higher than those for the photo polymerization. Thus, the hydrosilanes significantly influence on the polymerization as both chain-initiation and chain-transfer agents.

  • PDF

Study on Ophthalmic Materials Possessing UV-Blocking/Antimicrobial Functions (자외선 차단 기능을 가진 항균성 안 의료용 소재에 관한 연구)

  • Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.4
    • /
    • pp.460-464
    • /
    • 2010
  • We manufactured functional contact lens materials using 2-hydroxy-4-methoxy-benzophenone, titanium(VI) isopropoxide and nanogold, nanoplatinum with UV-blocking and antimicrobial effects. Contact lens was manufactured by cast mould method. The resulting mixture was copolymerized by heating at $70^{\circ}C$ for about 40 min, at $80^{\circ}C$ for about 40 min, and finally at $100^{\circ}C$ for about 40 min. The refractive index of 1.434 ~ 1.436, water content of 35.24 ~ 36.32%, and visible transmittance of 88.3 ~ 90.8% were obtained for the contact lens materials. The polymer materials satisfied the physical properties required to make the material suitable to be applied as a functional material for ophthalmological purposes.

Physical Properties of Styrene Copolymer and Contact Lens Application (스타이렌 공중합체의 물리적 특성 및 콘택트 렌즈로의 응용)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.755-760
    • /
    • 2009
  • Styrene is broadly used as a polymer and a copolymer and is useful in manufacturing contact lenses due to its high refractive index. This study used styrene with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical characteristics of the copolymerized material showed that the refractive index is 1.4412 - 1.4628, water content 20 - 35%, visible transmittance 82.6 - 87% and the tensile strength 0.143 - 0.344 Kgf. Also, measurements showed that the refractive index and tensile strength increased while the water content decreased as the ratio of styrene increased. Based on the results of this study, the produced copolymer can be estimated to be suitable for use as a material for high performance functional contact lenses.

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.